Raman

Mar 01, 2018
Spectroscopy
By Spectroscopy Editors
Igor K. Lednev, of the Department of Chemistry at the University at Albany, the StateUniversity of New York, has been developing the use of Raman spectroscopy for a varietyof forensic applications, including determining the age of blood stains and linking gunshot residues to specific ammunition–firearm combinations.
Mar 01, 2018
Spectroscopy
By Spectroscopy Editors
Duncan C. Krause, of the Department of Microbiology at the University of Georgia, discusses his group’s work to establish a SERS method with silver nanorod-array substrates for detecting the pathenogenic mycoplasma that causes bronchitis and pneumonia.
Nov 09, 2017
By Spectroscopy Editors
Two-dimensional (2D) Raman correlation spectroscopy is a powerful analytical technique for analyzing a system under the influence of an external perturbation. Isao Noda, of the Department of Materials Science and Engineering, at the University of Delaware and Danimer Scientific, has been developing 2D Raman correlation spectroscopy and applying it to the study of various materials, including exciting new biopolymers. He recently spoke to us about this work.
Nov 01, 2017
Spectroscopy
We show Raman spectra of polymeric fibers acquired as a function of increasing stress and temperature. With knowledge of Raman band assignments, it becomes possible to understand, in detail, the molecular changes that are responsible for polymer orientation and crystallization.
Sep 01, 2017
Spectroscopy
The apparent reaction kinetics between SO3 and polyethylene are investigated in various halogenated solvents using in situ Raman spectroscopy with an immersion Raman probe, demonstrating the power of in situ Raman spectroscopy to monitor hazardous reactions.
Sep 01, 2017
Spectroscopy
The Raman spectra of a particular face of a single crystal can be significantly different if acquired with different microscope objectives. This article explains the underlying physics of changes in relative intensity and even peak position of certain Raman bands depending on the microscope objective used to acquire the spectrum.
Jun 01, 2017
Spectroscopy
The resonance Raman spectra of carotenoids vary with subtle changes on the functional side groups, making these spectra useful for identifying and characterizing carotenoids.
Jun 01, 2017
Special Issues
Interference from background fluorescence is a common challenge in Raman analysis. A study of three different types of biological samples was made to compare the ability of 785-nm and 1064-nm excitation to deal with this problem.
Jun 01, 2017
Special Issues
A procedure was developed to calibrate the wavenumber (energy shift) axis in Raman spectrometers, and it was tested in both portable and laboratory-based instruments.
Jun 01, 2017
Special Issues
A simple SERS-based method was used to identify low doses of the APIs alprazolam, codeine, oxycodone, and hydrocodone using a handheld Raman spectrometer.
native1_300x100
lorem ipsum