FT-IR Spectroscopy

Mar 22, 2016
By Spectroscopy Editors
Matthew Baker, a senior lecturer in chemistry at the University of Strathclyde, in Glasgow, has won the inaugural Emerging Leader in Molecular Spectroscopy Award, which is sponsored by Spectroscopy magazine. This new annual award recognizes the achievements and aspirations of a talented young molecular spectroscopist, selected by an independent scientific committee. The award will be presented to Baker at the SciX 2016 conference in September, where he will give a plenary lecture and be honored in an award symposium.
Jan 01, 2016
Spectroscopy
A 12-step program to help you be more successful at interpreting IR spectra
Sep 11, 2015
By Spectroscopy Editors
Although near-infrared (NIR) spectroscopy is not a particularly sensitive technique, it can be implemented with little or no sample preparation and thus is well suited to applications such as process monitoring, materials science, and medical uses. We asked a panel of experts to comment on important current applications of NIR, as well as emerging new areas of application and the challenges involved in those newer applications.
Aug 01, 2015
Special Issues
Although handheld FT-IR spectrometers now make it possible to carry out field-based FT-IR analysis of soils at a crime scene, reliable and tested protocols are not yet available for such work. Here, we discuss sampling options and describe tests of a methodology that is being eveloped for in situ FT-IR analysis of soil samples.
Aug 01, 2015
Special Issues
Quality control of silicones used in medicinal implants is challenging, and traditional methods waste a lot of raw material. In this study, NIR spectroscopy has been used to replace the traditional rheometric measurements, with excellent results. The NIR method enables improved quality control and a more economical process.
Aug 01, 2015
Special Issues
Infrared multiple angle incidence resolution spectroscopy (IR MAIRS) provides a powerful new tool to determine the molecular structure and orientation in a thin film on an IR-transparent substrate. The MAIRS technique replaces a tedious, and sometimes impossible, combination of sample preparation and analysis of identical films on both transparent and reflective substrates.
Oct 01, 2014
Spectroscopy
Macro attenuated total reflection FT-IR spectroscopic imaging is a powerful and underutilized tool. This article presents an overview of approaches and opportunities for using this method to study dynamic processes such as diffusion, sorption, crystallization, and dissolution.
Aug 01, 2014
Special Issues
Resonance-enhanced atomic force microscopy (AFM)–infrared (IR) is a new technique that couples an atomic force microscope with a pulsed tunable IR laser source to provide high spatial resolution chemical analysis of samples as thin as a monolayer. The AFM probe tip acts as a small local detector of the thermal expansion of the sample caused by the absorption of the monochromatic IR radiation.
Aug 01, 2014
Special Issues
The mechanical properties of polymer films such as tensile strength and resistance to tearing depend strongly on the orientation of the polymer chains. Fourier transform infrared (FT-IR) spectroscopy can be used to measure the degree of orientation both within the plane of the film and normal to it.
Aug 01, 2014
Special Issues
Counterfeit and illicit tobacco may contain potentially toxic organic impurities that result in adverse health effects to the consumer. The aim of this work was to investigate the feasibility of the identification of organic impurities in counterfeit or illicit tobacco using attenuated total reflectance-Fourier transform infrared (ATR-FT-IR) spectroscopy.