ICP-MS

Nov 01, 2015
Special Issues
The performance of MS-MS mode and single-quadrupole mode are compared for titanium analysis.
Oct 07, 2015
By Spectroscopy Editors
Inductively coupled plasma–mass spectrometry (ICP-MS) is a powerful analytical technique. But like any other analytical techniques, there are challenges involved. We recently asked ICP-MS experts what unresolved problems exist—especially with samples in complex matrices—and how ICP-MS methods or technologies can be developed to attack them.
Jul 10, 2015
In honor of Spectroscopy’s celebration of 30 years covering the latest developments in materials analysis, we asked experts to assess the current state of the art of six key spectroscopic techniques. Here, the experts weigh in on what they considered the most important advance in inductively coupled plasma–mass spectrometry (ICP-MS) in the last 5–10 years.
Jun 01, 2015
Spectroscopy
In honor of Spectroscopy's celebration of 30 years covering the latest developments in materials analysis, we asked a panel of experts to assess the current state of the art of inductively coupled plasma–mass spectrometry (ICP-MS) and to try to predict how the technology will develop in the future.
Nov 01, 2014
Special Issues
By Spectroscopy Editors
Rare earth elements (REEs) have become indispensable in many electronic, optical, magnetic, and catalytic applications because of their specific properties such as magnetism and phosphorescence, as well as their ability to both donate and accept electrons.
Nov 01, 2014
Special Issues
By Spectroscopy Editors
This article compares several performance criteria such as full width at half maximum, background equivalent concentrations, limits of detection, purge requirements, and results for some substances for the "traditional" As lines at 188.979, 193.696, and 197.197 nm for the "new" line at 228.812 nm.
Nov 01, 2014
Special Issues
By Spectroscopy Editors
A novel approach to handling samples with very high and variable levels of sample matrix is to use aerosol dilution, whereby the amount of sample aerosol that reaches the plasma is reduced by dilution with an additional argon gas stream.
Nov 01, 2014
Special Issues
By Spectroscopy Editors
Multiple-collector inductively coupled plasma–mass spectrometry (MC-ICP-MS) has some specific advantages over traditional ICP-MS instruments.
Nov 01, 2014
Special Issues
Low-level analysis of food matrices has placed a demand on manufacturers, testing laboratories, and instrumentation vendors worldwide. Stricter regulations, better analytical instrumentation, and greatly improved sample preparation (preanalytical) techniques have focused efforts to simplify and standardize these analyses.
May 16, 2014
Spectroscopy
By Spectroscopy Editors
The California Department of Public Health has proposed to establish the first regulatory limit in the United States for hexavalent chromium (chromium-6) in drinking water. The proposed Maximum Contaminant Level (MCL) sets the limit for hexavalent chromium at 10 parts per billion. California, like those of other states and United States federal government, currently only regulates total chromium levels.