Lanthanide Series Investigations with TSI LIBS Desktop Analyzer


Application Notebook
pp. 10, 11


Figure 1: Neodymium measurements with TSI LIBS Desktop Analyzer.
The lanthanide series is a series of metallic elements, with atomic numbers 58 through 71, which are — in order of increasing atomic number — cerium, praseodymium, neodymium, promethium, samarium, europium, gadolinium, terbium, dysprosium, holmium, erbium, thulium, ytterbium, and lutetium. They have numerous commercial uses based on their individual chemical, optical, and nuclear properties. Examples of commercial use include use in control rods in nuclear reactors (gadolinium, dysprosium), as colors in glasses and enamels (praseodymium, neodymium, cerium), and as constituents in laser medium and solid state devices (neodymium and terbium).


Figure 2: Europium measurements with TSI LIBS Desktop Analyzer.
Lanthanides are often measured with spectroscopic means such as atomic absorption spectroscopy (AAS) and inductively coupled plasma (ICP) optical emission spectroscopy (OES). These methods involve acid digestion of the matrix prior to analysis. Direct analysis methods such as XRF can be problematic as the L series transitions used to analyze these elements often overlap the K series fluorescence from transition elements.

The TSIŽ LIBS Desktop Analyzer Solution


Figure 3: Lutetium measurements with TSI LIBS Desktop Analyzer.
The TSI LIBS Desktop Analyzer uses a technique known as laser induced breakdown spectroscopy (LIBS) to directly determine the elemental concentrations of lanthanides in materials. The examples below of lanthanide determination in graphite matrix illustrate that determination of dilute concentrations (low ppm) in many matrices is possible.

TSI Inc.
500 Cardigan Rd, Shoreview, MN 55126
tel. (800) 874-2811
Website: http://www.tsi.com/

Rate This Article
Your original vote has been tallied and is included in the ratings results.
View our top pages
Average rating for this page is: 0
Headlines from LCGC North America and Chromatography Online
The Benefits of Okra
UCT NA - Determination of Pesticide Residues in Tea: An AOAC Collaborative Study
Rapid detection of chemicals emitted from museum display cases
Saccharide tracers in aerosols
Investigation of Synthetic Compounds in Drug Discovery by Integrated HPLC and LC/MS
Source: Application Notebook,
Click here