The Moxtek ICE Cube Polarizing Beamsplitter


Application Notebook
pp. 18

A broadband polarizing beamsplitter (PBS) cube was developed using embedded Moxtek® Nanowire® grid polarizer technology. The Moxtek ICE Cube™ PBS provides superior performance in broadband, low f/# spectroscopic applications where both high efficiency and excellent contrast are required.

Cube beamsplitters are found in a variety of spectroscopic applications where matching path lengths, reduced ghosting, and limited beam shift are important. Polarizing beamsplitter cubes are found in phase-shifting laser interferometers, polarization sensitive optical coherence tomography, and polarization sensitive white light interferometry. PBS cubes are often used for applications that require compact designs and reduced mechanical vibration. Typically MacNeille cubes have been used for many PBS applications, but for low f/#'s (large cone angles), the color balance and the contrast ratio between passing and blocking state transmittance have been less than ideal. On the contrary, wire grid polarizers (WGP) are known for excellent broadband performance in low f/# applications. By incorporating a WGP along the hypotenuse of a cube beamsplitter, the Moxtek ICE Cube provides a superior PBS in low f/# applications.

Experimental Conditions


Figure 1: Low f/# performance comparison between polarizing beam splitter cubes. Measurement schematic (a) and results (b–c) showing blocking state transmittance (Ts) and reflectance (Rs) for MacNeille Cube (b) and Moxtek ICE Cube (c).
As depicted in Figure 1a, a white light LED source was collimated and passed through an iris followed by a high contrast pre-analyzer to select an input polarization state. The beam was then focused into Moxtek and MacNeille Cube beamsplitters and the blocking state transmittance (Ts) was minimized on a screen. The blocking state reflectance and transmittance were then imaged using a camera, as was the passing state transmittance and reflectance (after rotating pre-analyzers by 90°). In both cases the aperture was varied to change the f/#, and the images were taken at about f/1.2 cone angle.

Results

As shown in Figure 1, the ICE Cube (Figure 1c) has improved color balance and a reduced leakage in the blocking state (Ts) when compared to the MacNeille cube (Figure 1b). Both cubes were also characterized at variable angles with well collimated light from the UV to the SWIR. The Moxtek ICE Cube outperformed the MacNeille cube, accommodating angular deviations from normal incidence of ±20° in the azimuthal direction and ±10° in the polar (elevation) direction with minimal performance variation.

Conclusions

The Moxtek ICE Cube beamsplitter with embedded nanowire grid polarizer provides superior broadband performance over a wide angular aperture, with none of the dramatic color shifts and angular performance variations evident in MacNeille cube beamsplitters. While MacNeille cube designs can typically only tolerate a narrow angular aperture before performance deteriorates, the Moxtek ICE Cube accommodates a much larger angular field of view, allowing the optical designer to maintain system performance in broadband spectroscopic applications with demanding form factors.

Moxtek, Inc.
452 West 1260 North, Orem, UT 84057
tel. (801) 225-0930, fax (801) 221-1121
Website: http://www.moxtek.com/

Rate This Article
Your original vote has been tallied and is included in the ratings results.
View our top pages
Average rating for this page is: 1
Headlines from LCGC North America and Chromatography Online
Emerging Trends in Pharmaceutical Analysis
Detection of Low-Level Sulfur Compounds in Spearmint Oil
Water for GC-MS Analysis of VOCs
Differential Analysis of Olive Oils with Pegasus® GC-HRT and ChromaTOF-HRT® Reference Feature
Streamline Data Analysis of Tandem Mass Spectrometry for Inborn Errors of Metabolism Research
Source: Application Notebook,
Click here