Topographic and 3D Raman Imaging


Application Notebook
pp. 21

Confocal Raman imaging opened the door for many applications in Raman spectroscopy and imaging that were previously unavailable for measurement with conventional (non-confocal) Raman methods. However, high confocality always results in a high focus sensitivity and this can make measurements difficult with rough or inclined samples. The TrueSurface imaging extension resolves these problems and extends Raman imaging to large scale (> 1×1 mm2) samples without extensive tilt alignment or sample preparation and without comprising the advantages of confocal imaging. For the characterization of the inner properties of a sample with Raman Spectroscopy an ultrasensitive confocal Raman microscope allows the acquisition of a Raman image stack revealing 3D information on the distribution of the chemical compounds.

TrueSurface Microscopy for Topographic Raman Imaging


Figure 1: Topographic Raman image of an aspirin tablet obtained with the TrueSurface Microscopy Mode.
WITec's exclusive True Surface Microscopy mode makes it possible to perform confocal imaging measurements parallel with and guided by large area topographic scans (> 1×1 mm2). To achieve this unique capability, the WITec microscope series can be equipped with a highly precise sensor for optical profilometry. The large area topographic coordinates from the profilometer measurement are used to perfectly trace the samples surface in either confocal or confocal Raman imaging mode. Sample preparation is reduced to a minimum without having to compromise the confocality of the system. The TrueSurface Microscopy mode is beneficial for many applications, including the characterization of micromechanical, medical, or semiconductor devices, the mapping of functionalized surfaces, or the imaging of bio-medical or pharmaceutical material surface properties. Figure 1 shows a height profile of a pharmaceutical tablet (aspirin) with the confocal Raman measurement overlaid. The drugs are labeled red and blue respectively, while the excipient is shown in green. Topographic variation was more than 300 µm.


Rate This Article
Your original vote has been tallied and is included in the ratings results.
View our top pages
Average rating for this page is: 0
Headlines from LCGC North America and Chromatography Online
Teledyne EU - Validation of Volatile Organic Compound by USEPA Method 8260C
Thermo Fisher Scientific EU - Simplifying Complex Multi-Residue Pesticide GC-MS/MS Methodology
UCT NA - Determination of Pesticides in Strawberries Using QuEChERS Extraction, Quick QuEChERS Clean-up and GC/MS Detection
Teledyne NA - Achieving ppt Levels of Environmental Volatiles with a Headspace Sampler
Biotage EU - Fast Extraction of Metanephrine and Normetanephrine from Urine Using EVOLUTE EXPRESS CX SPE Plates
Source: Application Notebook,
Click here