End of the Spectrum: Spectroscopy Plays the Violin - - Spectroscopy
 Home   Mass Spectrometry   ICP-MS   Infrared   FT-IR   UV-Vis   Raman   NMR   X-Ray   Fluorescence  
Home
Magazine
Issue Archive
Subscribe/Renew
Special Issues
Reprints
The Application Notebook
Current Issue
Archive
Submission Guidelines
Training
SpecAcademy
E-solutions
Digital Edition
Subscribe to the Digital Edition
The Wavelength
Subcribe to The Wavelength
Subscribe to the MS E-news
Resources
Market Profiles
Information for Authors
SpecTube
Webcasts
Advertiser services
Contact Us
Columns
Atomic Perspectives
Chemometrics in Spectroscopy
Focus on Quality
Laser and Optics Interface
Mass Spectrometry Forum
The Baseline
Molecular Spectroscopy Workbench

End of the Spectrum: Spectroscopy Plays the Violin


Spectroscopy
Volume 22, Issue 2

Music aficionados have enjoyed the rich, soothing sounds of the violin for centuries, and arguably the most famous violins in history have come from the workshop of Antonio Stradivari. His line of Stradivarius violins have long been sought after by world-class musicians and collectors alike. Due to their limited availability (it is believed only 600 to 700 are still in existence), they command astronomical prices on the auction block. On May 16, 2006, a Stradivarius known as "The Christian Hammer" fetched a record price for a musical instrument at $3,544,000 at Christie's auction house in New York, New York.


An authentic Stradivarius violin rests on display in the Royal Palace, Madrid, Spain.
Although Stradivari made several types of string instruments during his lifetime, including violas, cellos, mandolins, guitars, and even one harp, it is his violins that are considered superior to all others ever made. The main reason is due to their unsurpassed sound quality, for which scientists and researchers have been trying to find the secret for decades. Several theories abound as to how Stradivari made his violins so pitch-perfect, such as that he took the wood to make his instruments from an old cathedral, or that the type of glue he used had a profound impact on the sound. However, in the past, no one has been able to provide a proper explanation for Stradivari quality, and very few have been able to reproduce it in modern string instruments. But Joseph Nagyvary, a biochemist formerly of Texas A&M University, has struck a chord in finding the solution to the Stradivari mystery by using spectroscopy.

Over a period of 20 years, Nagyvary was able to collect 80 milligrams of wood from the interior of three Stradivari instruments when they were sent away for repair or restoration. He and his colleagues then took the shavings back to their lab, where they used carbon-13 nuclear magnetic resonance spectroscopy and infrared spectroscopy to study the wood and find out exactly what these precious instruments were made of. What they discovered was that the outstanding sound of the instruments had less to do with the shape and quality of the wood and more to do with the chemical makeup of it. Nagyvary found that the wood used in Stradivari's instruments was dramatically different chemically from wood used in both modern instruments and instruments from the same time period made in England and France. Nagyvary believes that the violin backs were treated with wood preservers such as salts of copper, iron, and chromium, and that these salts were responsible for the eloquent sound. But the salts may also have altered the mechanical and acoustical properties of each instrument. A few years ago, Nagyvary found that treating maple with salt water and grape juice could produce a violin backboard similar to a Stradivarius. Later, he discovered that borax, used by Stradivari to prevent woodworm, had created a change in the wood that had a positive effect on the sound of the violin.

Nagyvary has made several violins by replicating Stradivari's techniques, with excellent results. In 2003, one such violin was tested head-to-head with a Stradivarius. Both violins were played behind a screen to an audience of trained musicians and music lovers. After both violins were played in four different pieces of music, the audience voted on each violin's tone qualities and projection. Surprisingly, Nagyvary's violin came out ahead, slightly outperforming the Stradivarius in each category.

Brian Johnson
Assistant Editor, Spectroscopy

Rate This Article
Your original vote has been tallied and is included in the ratings results.
View our top pages
Average rating for this page is: 3.9
Headlines from LCGC North America and Chromatography Online
The Benefits of Okra
UCT NA - Determination of Pesticide Residues in Tea: An AOAC Collaborative Study
Rapid detection of chemicals emitted from museum display cases
Saccharide tracers in aerosols
Investigation of Synthetic Compounds in Drug Discovery by Integrated HPLC and LC/MS
Source: Spectroscopy,
Click here