Market Profile: Low-Field and Fixed Magnet NMR

Spectroscopy
Volume 22, Issue 10

Market Profile: Low-Field and Fixed Magnet NMR

The high-flying field of nuclear magnetic resonance (NMR), which is continuing to see strong growth as it approaches the $1 billion mark in annual market revenues, overshadows the market for low-field and fixed magnet NMR. These systems are far simpler and less expensive than the larger systems many have come to think of when they hear the term NMR. The range of applications for low-field and fixed magnet NMR is vast, which is contributing to strong growth in demand.


Low field and fixed magnet NMR demand by application
Low-field and fixed magnet NMR instruments, which include time-domain NMR, utilize a relatively small magnet that typically is capable of powers of under 100 MHz. These magnets can be incorporated into a benchtop instrument, or in some models, they are designed as a separate module that can be located out of the way. This is in stark contrast to the often massive superconducting magnets used in moderate- to high-field NMR, which operate anywhere from 300 MHz to powers approaching 1000 MHz.

The range of applications for these low-field and fixed magnet NMR systems is very diverse, and generally falls into quality control and industrial uses. One of the more common applications is the inspection of toiletry and cosmetic products, such as fluoride levels in toothpaste, which falls into the broader category of pharmaceuticals. However, such NMR instruments also are used widely in the agriculture and food, and petrochemicals and polymers industries. Recent instrument introductions that allow the analysis of small living animals has helped create major demand from clinical research laboratories as well. The market for these instruments is estimated to break $70 million in 2007, and is expected to continue to see strong single-digit growth.

The foregoing data were based on SDi's market analysis and perspectives report titled Edition Global Assessment Report, 9th Edition: The Laboratory Life Science and Analytical Instrument Industry, September 2006 . For more information, contact Stuart Press, Senior Consultant, Strategic Directions International, Inc., 6242 Westchester Parkway, Suite 100, Los Angeles, CA 90045, (310) 641-4982, fax: (310) 641-8851, http://www.strategic-directions.com.641-4982, fax: (310) 641-8851, http://www.strategic-directions.com/.

Rate This Article
Your original vote has been tallied and is included in the ratings results.
View our top pages
Average rating for this page is: 2.07
Headlines from LCGC North America and Chromatography Online
The LCGC Blog: So Just How Well Set-Up is Your UV Detector?
Agilent EU - Achiral-Chiral Heart-Cutting 2D-LC Analysis of Chiral Pharmaceutical Substances
Wyatt EU - SEC-MALS of Transient Proteins
Thermo NA - Rapid Separation and Mass Spectrometry Detection of Intact Protein Samples Using Monolithic Capillary Columns
Wyatt NA - SEC-MALS of Transient Proteins
Source: Spectroscopy,
Click here