Analyzing Highly Fluorescing Cellulose-Based Excipients and Other Complex Molecules with a Novel 1030 nm Handheld Raman Analyzer - - Spectroscopy
 Home   Mass Spectrometry   ICP-MS   Infrared   FT-IR   UV-Vis   Raman   NMR   X-Ray   Fluorescence  
Home
Magazine
Issue Archive
Subscribe/Renew
Special Issues
Reprints
The Application Notebook
Current Issue
Archive
Submission Guidelines
Training
SpecAcademy
E-solutions
Digital Edition
Subscribe to the Digital Edition
The Wavelength
Subcribe to The Wavelength
Subscribe to the MS E-news
Resources
Market Profiles
Information for Authors
SpecTube
Webcasts
Advertiser services
Contact Us
Columns
Atomic Perspectives
Chemometrics in Spectroscopy
Focus on Quality
Laser and Optics Interface
Mass Spectrometry Forum
The Baseline
Molecular Spectroscopy Workbench

Analyzing Highly Fluorescing Cellulose-Based Excipients and Other Complex Molecules with a Novel 1030 nm Handheld Raman Analyzer


Spectroscopy
Volume 28, Issue 12, pp. 88

Handheld Raman analyzers have found widespread use in the pharmaceutical industry for excipients and raw materials verification, and in first responder/security applications. Most portable Raman units utilize lasers operating at 785 nm because of the relatively good signal strength at this wavelength.


Figure 1, 2: Raman spectra for material MCC Generic (top) and Croscarmellose (bottom) comparing a 785 nm laser and a 1030 nm laser. The Raman peak structure in both compounds is only evident when utilizing the 1030 nm laser.
There are many compounds that fluorescence strongly at 785 nm, causing a featureless background spectrum that obscures the telltale Raman signature. Compounds include the micro-crystalline cellulose (MCC) compounds used as excipients, and nutrients like Folic acid (vitamin B9). For security applications, Semtex and TNT precursors are good examples.


Figure 3: Raman spectrum from a common plastic explosive Semtex. The characteristic Raman peak structure is only evident when using the 1030 nm laser compared to the 785 nm.
SciAps has introduced a handheld Raman analyzer utilizing a novel 1030 nm laser source – SWIR Raman. The 1030 nm laser yields reduced fluorescence compared to 785 nm lasers. The 1030 nm laser is compatible with a proprietary Type III-IV sensor that requires less cooling than analyzers using 1064 nm laser sources. There are no cooling fans required, and smaller batteries may be used. Therefore a 1030 nm system is very portable, and is sealed to IP67 standards, making it dunkable and washable for quarantine or hotzone use.

One Example: MCC Generic and Croscarmellose

MCC is a particularly good example. MCC can be modified to different degrees of crystalinity usually in the range of 40 to 60%. Raman spectra from MCC generic and Croscarmellose, using the 785 nm laser (Inspector 300) and the 1030 nm laser (Inspector 500) are shown in Figures 1 and 2. The Raman peaks of the MCC and Croscarmellose clearly stand out at 1030 nm but are lost in the featureless fluorescence background at 785 nm. A similar benefit is shown for plastic explosive Semtex. Semtex is a combination of PETN and cyclonite (cyclotrimethylenetrinitramine) that contains complex double bonded N, C, and O structures that produce fluorescence at 785 nm laser wavelengths. As shown in Figure 3 this material is easily identified with a 1030 nm laser source.

SciAps, Inc.
2 Constitution Way, Woburn, MA 01801
tel. (339) 927-9455
Website: http://www.sciaps.com/

Rate This Article
Your original vote has been tallied and is included in the ratings results.
View our top pages
Average rating for this page is: 1
Headlines from LCGC North America and Chromatography Online
Your chromatography alert from LCGC Europe
Diamond Analytics NA - Separation of Apo-Transferrin and Bovine Serum Albumin (BSA) Proteins
Markes International EU - Rapid detection of chemicals emitted from museum display cases
Dwight Stoll Wins Henry Dreyfus Teacher-Scholar Award
LCGC TV Library
Source: Spectroscopy,
Click here