Special Issues-05-01-2018

Special Issues

Resolving Volume-Restricted Metabolomics Using Sheathless Capillary Electrophoresis–Mass Spectrometry

May 01, 2018

Articles

16

2

Recent advances have significantly improved the performance of capillary electrophoresis–mass spectrometry (CE–MS) for the profiling of polar and charged metabolites in volume-restricted or mass-limited biological samples. Here, those advances are discussed, and attention is also devoted to various technical aspects that still need to be addressed.

The Use of MALDI Imaging Mass Spectrometry for Interdisciplinary Research: From Metabolomics to Pesticides

May 01, 2018

Articles

16

2

Matrix-assisted laser desorption–ionization (MALDI) imaging mass spectrometry allows direct, in situ, label-free measurement of proteins, peptides, lipids, small-molecule drugs and their metabolites, and other chemicals in tissues. In a range of applications, the unique information generated by MALDI imaging can make a significant contribution to understanding factors such as molecular and metabolic mechanisms and the transport and localization of compounds or metabolites with human, animal, or plant species.

Liquid Chromatography–Atmospheric Pressure Photoionization-Mass Spectrometry Analysis of the Nonvolatile Precursors of Rancid Smell in Mayonnaise

May 01, 2018

Articles

16

2

For lipid-containing food products like mayonnaise, determining nonvolatile lipid oxidation products, the precursor compounds for rancidity, makes it possible to predict product shelf life at an earlier stage in product development. A method based on normal-phase liquid chromatography with atmospheric pressure photoionization-mass spectrometry (LC–APPI-MS) was developed for this purpose.

Recent Advances and Trends in Inductively Coupled Plasma–Mass Spectrometry and Applications

May 01, 2018

Articles

16

2

There have been exciting recent advances in ICP-MS instrumentation, such as the development of magnetic sector ICP-MS, multicollector ICP-MS, time-of-flight ICP-MS, and triple-quadrupole ICP-MS, as well as developments in the coupling of laser ablation (LA) and laser-induced breakdown spectroscopy (LIBS) to ICP-MS. This article surveys these developments and looks to the future.

Vol 16 No 2 Current Trends in Mass Spectrometry May 2018 Issue PDF

May 01, 2018

Issue PDF

16

2

Click the title above to open the May 2018 issue of Current Trends in Mass Spectrometry, Volume 16, Number 2, in an interactive PDF format.