May 16th 2024
A recent study published in Analytical Chemistry examines using atomic force microscopy (AFM) in nanoscale chemical imaging in liquid and air environments.
Investigating Forensics Applications of Raman Spectroscopy, ATR FT-IR, and Chemometrics
December 10th 2021As forensic analysis continues to advance, such as in the understanding of source identification and analysis of trace quantities of bodily fluids, spectroscopic techniques and machine learning are playing a significant role. Igor K. Lednev, a chemistry professor at the University at Albany, SUNY, in Albany, New York, has been working in this field with his team. The analytical methods currently under investigation include Raman spectroscopy, attenuated total reflection Fourier transform infrared (ATR FT-IR) spectroscopy, and advanced chemometric classification and analysis methods. We recently interviewed him about his work.
High-Definition Fourier Transform Infrared Spectroscopic Imaging of the Tumor Microenvironment
September 2nd 2021Professor Rohit Bhargava and his team at the University of Illinois, where they have established the Cancer Center at Illinois, are advancing research in tumor microenvironments, using techniques such as high-definition Fourier transform infrared (HD-FT-IR) coupled with machine learning. We recently spoke to Bhargava about this work.
Common Problems with FT-IR Instruments and How to Avoid Them
September 2nd 2021Those inexperienced in using FT-IR spectrometers can encounter problems when measuring spectra. This article discusses several main issues that most users experience while using FT-IR spectrometers and how to remedy each problem.
Resonant Surface-Enhanced Infrared Spectroscopy (Resonant SEIRA) Using Metal Nanoantennas
August 1st 2021Resonant SEIRA overcomes the limitations of traditional Fourier transform infrared (FT-IR) spectroscopy for minute sample sizes of relatively low absorptivity. Frank Neubrech of Heidelberg University is exploring resonant SEIRA in applications such as monitoring dynamic processes and hyperspectral infrared chemical imaging.
Fingerprinting of Mineral Medicine Natrii Sulfas by Fourier Transform Infrared Spectroscopy
June 1st 2021We show how FT-IR may be used for quality control analysis of natrii sulfas, a transparent crystalline material used in natural medicine that primarily contains sodium sulfate decahydrate, crystallized from sulfate minerals.
The Grand Review I: Why Do Different Functional Groups Have Different Peak Positions?
November 1st 2020Articles in this column have addressed five main areas: theory, functional groups containing the C-H bond, those containing the C-O bond, those with the C=O bond, and those with organic nitrogen compounds. Here, we review the concepts.
Insights Toward Standardization of the Analysis of Microplastics by Infrared Microscopy
August 1st 2020Here we conduct an evaluation of significant operational parameters of IR microscopy for accurately determining the size of microplastics, with the overarching goal of outlining performance parameters that will help in the standardization of microplastics analysis.
Organic Nitrogen Compounds VIII: Imides
March 1st 2020Here, we continue our examination of the infrared (IR) spectra of organic nitrogen compounds with imides, which are a common chemical intermediate. IR can be used not only to identify imides, but also to distinguish between straight chain and cyclic imides. We explain how.