Application Notebook
Savillex's DST Acid Purification Systems are used by laboratories worldwide for the on-demand production of high purity acid for use with ICP-MS and other metals analysis techniques. Savillex recently expanded the product line with the new DST-4000, which is a high-throughput, fully-automated system capable of producing 4 L of high-purity acid at a time, completely unattended.
Figure 1: Savillex DST-4000.
The ultra-low detection limits of ICP-MS necessitate the use of high-purity grade acids for standards, sample dilutions, and, increasingly, even for sample digestion. Although commercially available bottled high-purity (10 ppt grade) acid is readily available, it costs up to 10 times more than trace metal (1 ppb) grade acid. Once opened, and during use, a bottle of high-purity acid can easily become contaminated due to airborne contamination or analyst error. For these reasons, many laboratories are producing their own high-purity acid using the Savillex DST-1000 Acid Purification System. The DST-1000 produces HNO3, HCl, and HF that is as good as or better than commercially available acid (Table I), is easy to use, has a small footprint, and can pay for itself in months, or even weeks, depending on the laboratory's acid needs.
Although in-laboratory production of high purity acid can easily be justified financially, some laboratories prefer to continue to purchase bottled high-purity acid. This is because there was no system that could either produce enough acid to meet their needs, or be operated completely unattended thus requiring additional labor. Recently, Savillex released the DST-4000. The quality of acid produced by the new DST-4000 is the same as the DST-1000, however the DST-4000 can produce 1 L of acid in 12 h-double the throughput of the DST-1000. In addition, its acid level sensor and auto-shutoff feature allows it to be run completely unattended. Acid (up to 4 L at a time) is simply added to the DST-4000 via the conveniently located front fill tube, the unit is switched on using the external controller, and the user walks away. High-purity acid is collected in a pair of 2 L Purillex™ PFA bottles, and the DST-4000 switches off automatically when the run is completed. The acid in the collection bottles is protected from the environment by specially designed closures, and ready for use when needed. The in-laboratory production of high-purity acid has never been easier or more convenient.
Savillex Corporation
10321 West 70th St., Eden Prairie, MN 55344-3446
tel. (952) 935-4100
Website: www.savillex.com
Getting accurate IR spectra on monolayer of molecules
April 18th 2024Creating uniform and repeatable monolayers is incredibly important for both scientific pursuits as well as the manufacturing of products in semiconductor, biotechnology, and. other industries. However, measuring monolayers and functionalized surfaces directly is. difficult, and many rely on a variety of characterization techniques that when used together can provide some degree of confidence. By combining non-contact atomic force microscopy (AFM) and IR spectroscopy, IR PiFM provides sensitive and accurate analysis of sub-monolayer of molecules without the concern of tip-sample cross contamination. Dr. Sung Park, Molecular Vista, joined Spectroscopy to provide insights on how IR PiFM can acquire IR signature of monolayer films due to its unique implementation.
Deep Level Transient Spectroscopy Reveals Influence of Defects on 2D Semiconductor Devices
April 25th 2024A recent study used deep level transient spectroscopy to investigate the electrical response of defect filling and emission in monolayer metal-organic chemical vapor deposition (MOCVD)-grown materials deposited on complementary metal-oxide-semiconductor (CMOS)-compatible substrates.