X-ray fluorescence spectroscopy (XRF) is one of the primary analytical tools used in the cement industry for a variety of related applications. The principle of XRF is relatively simple; a source directs X-rays onto the atoms of the sample, ejecting electrons from the inner electron shells.
X-ray fluorescence spectroscopy (XRF) is one of the primary analytical tools used in the cement industry for a variety of related applications. The principle of XRF is relatively simple; a source directs X-rays onto the atoms of the sample, ejecting electrons from the inner electron shells. As electrons fall into the resulting holes, characteristic X-rays are released, which can be analyzed by a spectrometer to identify the elementary composition of the sample. The two main types of XRF instruments, energy dispersive (EDXRF) and wavelength dispersive (WDXRF), use different methods to analyze the X-ray spectrum. Generally speaking, WDXRF offers finer spectral resolution, but has a higher price tag.
2007 Global Cement Production
Despite the greater expense, WDXRF is indispensible in the cement industry. Samples include raw materials like sand and lime, finished cement products, and samples grabbed from the production process. The elemental composition of samples gives information about the purity of the sample, but also the state of oxidation of the cement, an important measure of quality. EDXRF is also used, typically in a supporting role, for the same types of applications. Samples are prepared either as pressed pellets or, for greater homogeneity, fused into a glass disk.
As an industry, cement is currently of enormous importance in Asia, which is home to more than two-thirds of both production and consumption of cement. China alone is responsible for about half the global market. This has some environmental implications as well, as China is now the largest global source of CO2 emissions, with cement production responsible for nearly 10% of the country's CO2 output.
Some of the foregoing data were extracted from SDi's market analysis and perspectives report entitled Global Assessment Report, 9th Edition: The Laboratory Life Science and Analytical Instrument Industry, September 2006. For more information, contact Michael Tice, VP of Consulting Services, Strategic Directions International, Inc., 6242 West-chester Parkway, Suite 100, Los Angeles, CA 90045, (310) 641-4982, fax: (310) 641-8851, www.strategic-directions.com.
University of Pennsylvania Graduate Researcher Wins SPIE Medical Imaging Student Paper Award
March 14th 2024A PhD student in the Department of Bioengineering at the University of Pennsylvania has won the 2024 Physics of Medical Imaging Student Paper Award, which is given out annually by the International Society for Optics and Photonics (SPIE), at the Medical Imaging Symposium in San Diego, California.