|Articles|April 22, 2014

Near Infrared Spectroscopy Used to Detect Impaired Tissue Oxygen Saturation

A new study by researchers at the Department of Anesthesia and Perioperative Medicine, at the Schulich School of Medicine and Dentistry (Ontario, Canada) used near infrared spectroscopy (NIRS) to detect impaired tissue oxygen saturation in patients with this syndrome.

A new study by researchers at the Department of Anesthesia and Perioperative Medicine, at the Schulich School of Medicine and Dentistry (Ontario, Canada) used near infrared spectroscopy (NIRS) to detect impaired tissue oxygen saturation in patients with this syndrome.

The purpose of the study was to determine if NIRS could detect differences in deep tissue oxygen saturation and microcirculatory function in the hands of patients with CRPS 1.

The researchers evaluated tissue oxygen saturation at baseline and during an ischemia reperfusion challenge using vascular occlusion testing in affected versus unaffected hands of patients with unilateral upper limb CRPS 1. A non-randomized experimental study design was used with baseline deep tissue oxygen saturation as the primary measure.

The results showed that independent of handedness, the baseline oxygen saturation of the affected hands of ten patients was significantly lower than that of their unaffected hands. The baseline oxygen saturation of affected hands was also significantly lower than that of the non-dominant hands of 10 volunteers.

The researchers concluded that hands of patients affected by CRPS 1 of the upper limb showed significantly lower deep tissue oxygen saturation compared with their unaffected hand as well as the hands of control subjects.


Related to this article

Why Reproducibility Starts with Sample Preparation
In this segment of his SciX interview, Marc Porter explains why every step matters when measuring at picomolar and femtomolar levels, and how switching to proteinase K helped make his group’s tuberculosis work more clinic-ready.
Electromagnetic electric field background | Image Credit: © pixel - stock.adobe.com.
In this clip from our SciX interview with Siddhartha Das, he describes his team’s “eureka moment”: the discovery that the ion distribution inside a polymer layer shapes how water moves under an electric field. He also explains why experimental confirmation is still years away.
2026 SciX Conference Summary ©   Bos Amico -chronicles-stock.adobe.com
SciX 2026, the annual conference presented by the Federation of Analytical Chemistry and Spectroscopy Societies (FACSS), ran October 4–9, 2026, at the Nugget Casino Resort in Sparks, Nevada. The program spanned atomic and molecular spectroscopy, mass spectrometry, chemometrics, and bioanalysis. This report follows the meeting day by day, from Monday's clinical Raman plenaries to Friday's closing talks, drawing on the online program and Spectroscopy coverage of award winners, highlighting efforts to move Raman, SERS, LIBS, and single-particle ICP-MS toward clinical, environmental, and field use.