Product Resources
Mass spectrometer
Thermo Fisher Scientific's LTQ Orbitrap XL mass spectrometer is designed for protein identification and biomarker discovery. The instrument reportedly features high sensitivity in MS and MSn, a rapid scan rate, high mass accuracy, and up to 100K resolution power. According to the company, the product includes an octapole collision cell for increased flexibility in MS-MS fragmentation applications such as peptide quantitation, PTM analysis, de novo sequencing, and metabolomics research. Thermo Fisher Scientific, Waltham, MA; www.thermofisher.com
Circle 100
GC–MS system
PerkinElmer's Clarus 560 D GC–MS system is designed for lower-volume laboratories' routine application needs. According to the company, the system offers increased productivity through state-of-the-art electronics, the fastest scanning rates to yield the most accurate data, the widest mass range, and the latest in reporting capabilities for easy environmental compliance. The compact system also includes a GC autosampler, a touch-screen interface, and dual channels for additional application work. Perkin Elmer, Inc., Wellesley, MA; www.perkinelmer.com
Circle 101
MALDI TOF/TOF
The 4800 Plus MALDI TOF/TOF Analyzer from Applied Biosystems is a time-of-flight MS/MS system that reportedly provides high levels of protein coverage and throughput in quantitative proteomic analysis. According to the company, the product is the only commercially available MALDI TOF/TOF mass spectrometer with on-axis laser irradiation, enabling sensitivity in the attamole range. Applied Biosystems, Foster City, CA, www.appliedbiosystems.com
Circle 102
CID MS-MS system
Shimadzu's AXIMA-TOF2 mass spectrometer reportedly features the highest collision energy available for a TOF-TOF instrument. The mass spectrometer is designed to collect both PSD- and CID-generated ions simultaneously. According to the company, the product's ion gating technology affords precursor ion isolation resolution, allowing the successful MS-MS analysis of complex mixtures. Shimadzu Scientific Instruments, Columbia, MD; www.ssi.shimadzu.com
Circle 103
TOF MS
Hitachi's NanoFrontier with TOF MS is designed for preserving posttranslational modifications (PTM) with electron capture dissociation (ECD), which allows definitive PTM site and type determinations. According to the company, the product provides high-throughput intelligent control of combined ECD and CID scans for interrogation of modified proteins. Hitachi High Technologies America, San Jose, CA; www.hitachi-hta.com
Circle 104
MS system
The Waters Synapt High Definition MS (HDMS) system is designed for researchers working at the limits of conventional MS and who need to further characterize and define complex samples. The system reportedly uses an ion-mobility-based measurement and software to analyze sample ions differentiated by size and shape. According to the company, this additional dimension of separations fidelity leads to improved specificity and sample definition. Waters Corporation, Milford, MA; www.waters.com
Circle 105
Mass spectrometer
Bruker Daltonics introduces the apex-ultra FTMS mass spectrometer, which reportedly features a wide dynamic range, high resolving power, high mass accuracy, and fast data acquisition. According to the company, the product is designed for top-down proteomics and the analysis of complex mixtures in applications such as metabolomics or petroleomics. Bruker Daltonics, Billerica, MA; www.bdal.com
Circle 106
Ion sources
Prosolia's Omni Spray Ion sources are a series of ionization sources based on desorption electrospray ionization (DESI). DESI is a simple, sensitive, gentle, and versatile ionization method that allows for the direct and rapid sampling of surfaces without any sample preparation and under ambient temperature and pressure conditions. According to the company, with this source, scientists are able to analyze both large and small molecules from a variety of surfaces. Prosolia, Inc., Indianapolis, IN; www.prosolia.com
Circle 107
UV-vis spectrophotometer
Hitachi's model U-2900 is a UV-vis local control double-beam spectrophotometer designed for routine as well as research laboratory applications. According to the company, the product is equipped with a 10.4-in. color liquid crystal display, data storage with an external USB flash disk, a validation function that allows users to check performance, and optional PC control using the company's UV Solutions software. Hitachi High Technologies America, San Jose, CA; www.hitachi-hta.com
Circle 108
Ion mobility spectrometer
The TSI 3980C MacroIMS ion mobility spectrometer is designed for fast separation of macromoles. According to the company, the instrument's software allows overlay of spectra, raw data smoothing, and molecular weight-based controls and statistics. TSI Incorporated, Shoreview, MN; www.tsi.com
Circle 109
Mass spectrometers
Agilent's 6100 series single-quadrupole mass spectrometers are designed to obtain high-quality MS data across chromatographic peaks with widths as narrow as 1 s. According to the company, the systems provide maximum spectral information confirming that the correct peaks are being identified and faster POS/NEG mode switching. Agilent Technologies Inc., Wilmington, DE; www.agilent.com
Circle 110
Tubing
Capillary PEEK tubing from Upchurch is designed for use in ultralow-flow, small-particle-column applications. According to the company, the 25-μm i.d. tubing has been tested with water to withstand pressures greater than 7000 psi (482 bar) at room temperature. Upchurch Scientific, Oak Harbor, WA; www.upchurch.com
Circle 111
Getting accurate IR spectra on monolayer of molecules
April 18th 2024Creating uniform and repeatable monolayers is incredibly important for both scientific pursuits as well as the manufacturing of products in semiconductor, biotechnology, and. other industries. However, measuring monolayers and functionalized surfaces directly is. difficult, and many rely on a variety of characterization techniques that when used together can provide some degree of confidence. By combining non-contact atomic force microscopy (AFM) and IR spectroscopy, IR PiFM provides sensitive and accurate analysis of sub-monolayer of molecules without the concern of tip-sample cross contamination. Dr. Sung Park, Molecular Vista, joined Spectroscopy to provide insights on how IR PiFM can acquire IR signature of monolayer films due to its unique implementation.
New Probes for NIR Monitoring of Polymer Injection Molding Composition in Real-Time
May 2nd 2024Researchers from Kyoto University and Japan's National Institute of Advanced Industrial Science and Technology have developed innovative probes to monitor the chemical composition of biodegradable polymer blends during injection molding. This breakthrough could lead to improved production efficiency and reduced waste in the polymer industry.