Product Resources
Cartridge system
Phenomenex's SecurityGuard PREP system is designed to protect preparative LC columns from the damaging effects of chemical contaminants and microparticulates. The system consists of a reusable, stainless steel holder and a 10-mm × 21.2-mm i.d. cartridge. According to the company, replacement cartridges are available in a variety of universal bonded phases that can be matched with most HPLC material. Phenomenex, Inc., Torrance, CA; www.phenomenex.com
Circle 100
LC columns
Michrom's LC columns are designed with inner diameters of 0.075–2.0 mm and lengths of 50, 100, and 150 mm. Several packing materials are available. The microbore columns are made of glass-lined stainless steel with titanium frits. Nano and capillary columns are made of fused silica sheathed with PEEK and include titanium frits. The company's Magic Bullet high throughput columns are made of injection-molded PEEK and also include titanium frits. Michrom, Auburn, CA; www.michrom.com
Circle 101
SPE instrument
Gilson's GX-274 ASPEC SPE instrument is designed to maximize efficiency and throughput with the unattended, parallel processing of samples via solid-phase extraction. The four-probe instrument's two dual syringe pumps reportedly allow users to transfer liquids, process up to four samples in parallel, and monitor pressure on each fluid path individually. Gilson, Inc., Middleton, WI; www.gilson.com
Circle 102
MS system
The Waters Synapt High Definition MS (HDMS) system is designed for researchers working at the limits of conventional MS and who need to further characterize and define complex samples. The system reportedly uses an ion-mobility-based measurement and software to analyze sample ions differentiated by size and shape. According to the company, this additional dimension of separations fidelity leads to improved specificity and sample definition. Waters Corporation, Milford, MA; www.waters.com
Circle 103
Automated evaporator-concentrator
The DryVap automated concentrator system from Horizon is designed to combine Kuderna-Danish concentration, nitrogen blow down, and drying of organic solvents into one step with precision and accuracy for GC and GC–MS analyses. According to the company, the benchtop system uses a separation membrane that automatically dries solvents in seconds and that concentrates solvent volumes of 2–200 mL to precisely 0.9 mL in less than 30 min. Horizon Technology, Inc., Salem, NH; www.horizontechinc.com
Circle 104
Capillary GC guard column
SGE's forte BPX5 columns are designed with the company's SilGuard integrated guard column. According to the company, the guard column traps nonvolatile material before it reaches the analytical column. The guard column's design reportedly enables the analytical and guard columns to have different internal diameters. SGE, Inc., Austin, TX; www.sge.com
Circle 105
Pumps
BOC Edwards' STP Turbomolecular pumps are designed with a pumping performance range of 300–3500 L/s. According to the company, the use of magnetic bearings ensures no risk of vacuum contamination, very low vibrations levels, and minimum maintenance. The pumps reportedly come with a three-year warranty for most general vacuum applications. BOC Edwards, Wilmington, MA; www.bocedwards.com
Circle 106
Nanoflow LC system
Hitachi's NanoLC chromatography system is designed for research laboratories. The system reportedly can be configured for two-dimensional chromatography enabling complete online separations of complex protein samples. According to the company, the system provides gradient and retention time reproducibility at nanoflow rates (50 nL/min). Hitachi High Technologies America, Inc., Schaumburg, IL; www.hitachi-hta.com
Circle 107
HPLC columns
Restek offers Kromasil HPLC packings in columns of all dimensions. According to the company, the columns offer high-quality, highly reproducible materials. Many columns are in stock for immediate shipment. Restek Corporation, Bellefonte, PA; www.restek.com
Circle 108
Detector software
Polymer Laboratories' Cirrus version 3 software is based on the company's GPC/Multi Detector software for polymer characterization. The software reportedly features a user interface with easier, more intuitive operation, expanded reporting and reviewing capabilities, and the ability to review all results within a workbook simultaneously. The software reportedly offers procedures for correcting the chromatographic band broadening of peaks. Polymer Laboratories, a Varian, Inc. Company, Amherst, MA; www.polymerlabs.com
Circle 109
Seals
Orochem's Oro-CZ Clear Zone seals feature a clear zone above each well that is free of adhesive. According to the company, clear zones and end tabs facilitate well alignment. The seals reportedly are inert and chemical resistant. The company's Oro-X Precut seals are designed to protect samples and limit evaporation, short-term. The seals feature hairline X-cuts and thin adhesive that is designed to prevent fouling. The film is designed to reseal for continued sample protection after sampling. Orochem Technologies Inc., Lombard, IL; www.orochem.com
Circle 110
HPLC column
Dionex's ProPac HIC-10 silica-based high-capacity HPLC column is designed for the separation of proteins and peptides by hydrophobic interaction chromatography. According to the company, the column has been used for applications ranging from the separation of serum proteins, human skeletal muscle total protein, and snake venom proteins to pancreatin and monoclonal antibodies. The column's stationary phase is based on 5-mm ultrahigh-purity spherical silica gel particles, with 300-Å pores. Dionex Corporation, Sunnyvale, CA; www.dionex.com
Circle 111
LC system
Nanostream's CL LC system is designed to increase analytical throughput 24-fold and reduce costs for a range of applications including purity, solubility, comparative stability, formulation, and dissolution studies. The system is designed to integrate with existing laboratory instruments. The system consists of a six- or eight-needle autosampler, binary pumps, real-time UV absorbance detection, and software. Nanostream, Pasadena, CA; www.nanostream.com
Circle 112
HPLC system
Agilent's 1200 series HPLC system is designed with more than 60 instrument modules and can be configured for standard, nanoflow, capillary, narrow, prep-scale, and chip-based liquid chromatography. The system reportedly is compatible with the company's 1100 series and is available in a Rapid Resolution configuration featuring more than 70 new RRHT columns. Agilent Technologies, Inc., Palo Alto, CA; www.agilent.com/chem
Circle 113
Dynamic coating
MicroSolv's CElixir-MS dynamic coating is designed for reproducible CE–MS. According to the company, the coating for bare fused-silica capillaries makes the EOF reproducible and allows the use of MS-compatible CE buffers. MicroSolv Technology Corporation, Eatontown, NJ; www.mtc-usa.com
Circle 114
GC-MS system
Shimadzu's QP-2010 Plus GC–MS system is designed for rapid analysis of difficult samples, the determination of trace components, and the characterization of complex organic mixtures. The system reportedly provides a 1.5–1090 m/z mass range as well as a 100–300 °C ion source temperature range. Shimadzu Scientific Instruments, Inc., Columbia, MD; www.ssi.shimadzu.com
Circle 115
Ultrahigh-pressure LC injector
Valco's Cheminert model C72 UPLC injector is designed with a proprietary stator coating that permits pressures up to 15,000 or 20,000 psi. The company offers an optional microelectric actuator, which determines accurate positioning without limit switches or customer adjustment. The injector can be controlled manually or by computer. The injector is available in 4-, 6-, 8-, and 10-port configurations with bore diameters of 0.004, 0.006, or 0.010 in. Valco Instruments Co., Inc., Houston, TX; www.vici.com
Circle 116
Software
ACD/Labs' ACD/IntelliXtract LC–MS software for automated molecular weight determination, component extraction, and sample comparison is designed to mimic the approach an expert mass spectrometrist would use for spectrum interpretation. According to the company, the software considers ion adducts, multimers, 12C/13C ratios, isotopes, neutral losses, and fragment ions. Advanced Chemistry Development, Inc., Toronto, Ontario, Canada; www.acdlabs.com
Circle 117
SFC instruments
Thar's SFC instruments are designed for pharmaceutical R&D laboratories. The company offers analytical-, preparative-, and process-scale equipment. The SFC instruments can be integrated with the Waters Micromass ZQ (MassLynx/OpenLynx) instruments. Thar Technologies, Inc., Pittsburgh, PA; www.thartech.com
Circle 118
Electron multiplier selection guide
BURLE's Channeltron Electron Multiplier Selection Guide provides a cross reference of detectors, instrument manufacturers, and electron multiplier products. BURLE Electro-Optics, Inc., Sturbridge, MA; www.burle.com
Circle 119
Evaporative light-scattering detector
Alltech's model 3300 evaporative light-scattering detector is designed for simple operation, easy maintenance, and maximum sensitivity. The detector features programming methods with a step-by-step method wizard available in seven languages. Parts requiring cleaning can be accessed from the instrument's front panel. Grace Davison Discovery Sciences, Deerfield, IL; www.discoverysciences.com
Circle 120
Nano flow sensor
Upchurch's noninvasive nano flow sensor, developed in cooperation with Honeywell, reports flow rates in the nanoliter through low microliter-per-minute range. According to the company, the sensor uses MEMS-based thermal anemometry to measure the mass-flow rate of liquids in an isolated flow channel and display it on an LCD readout. The sensor reportedly provides high sensitivity, ultrafast response, high accuracy, and low drift. Upchurch Scientific, Oak Harbor, WA; www.upchurch.com
Circle 121
Hybrid FTICR mass spectrometer
Thermo's Finnigan LTQ FT Ultra is a hybrid FTICR mass spectrometer designed to analyze complex matrices and large molecules with independent sub ppm mass accuracy, high resolution in excess of 750,000, and improved detection circuitry. The product is equipped with an ICR cell design, the Ultra Cell, which reportedly improves sensitivity and widens the dynamic range to exceed 4000 on an LC timescale. Thermo Electron Corp., Waltham, MA; www.thermo.com
Circle 122
Power supply
The TOF3000 power supply by Spellman is designed specifically for mass spectrometry applications, reportedly providing 0-30kV @ 400uA's with only 70mV peak to peak of ripple and noise. The unit also has a remote TTL-controlled output polarity reversing capability. Spellman High Voltage, Hauppage, NY; www.spellmanhv.com
Circle 123
Getting accurate IR spectra on monolayer of molecules
April 18th 2024Creating uniform and repeatable monolayers is incredibly important for both scientific pursuits as well as the manufacturing of products in semiconductor, biotechnology, and. other industries. However, measuring monolayers and functionalized surfaces directly is. difficult, and many rely on a variety of characterization techniques that when used together can provide some degree of confidence. By combining non-contact atomic force microscopy (AFM) and IR spectroscopy, IR PiFM provides sensitive and accurate analysis of sub-monolayer of molecules without the concern of tip-sample cross contamination. Dr. Sung Park, Molecular Vista, joined Spectroscopy to provide insights on how IR PiFM can acquire IR signature of monolayer films due to its unique implementation.