SPEC PerkinElmer 10.13
|Articles|July 12, 2017

Solving Polymer Problems Using IR Spectroscopy

Naoto Nagai, of the Industrial Research Institute of Niigata Prefecture in Japan, has been studying the potential of IR spectroscopy for investigating higher-order structures of polymers. He and his colleagues recently looked at the IR spectra of polyoxymethylene (POM) mold plates and the cause of occasional resin cracks.

Infrared (IR) spectroscopy is a versatile analytical technique that has found application in a great variety of industries. Naoto Nagai, of the Industrial Research Institute of Niigata Prefecture in Japan, has been studying the potential of IR spectroscopy for investigating higher-order structures of polymers. He and his colleagues recently looked at the IR spectra of polyoxymethylene (POM) mold plates and the cause of occasional resin cracks. Nagai is the 2017 recipient of Sciex’s William F. Meggers Award in Applied Spectroscopy. Here, he describes his research in this area, the method used, and the challenges involved.

You have been investigating the IR spectra of polyoxymethylene (POM) mold plates to determine the submicrometer-scale morphology and molecular orientation (1). What factors led you to perform this research?

We work in the business of informing companies, by using various analytical techniques, about the causes of problems such as resin cracks. In this work, we referred to the many papers published so far on the topic. However, we were not able to understand the cause of POM resin cracks in some cases. The measurements of IR in the papers referred to were usually conducted using KBr or Nujol methods, but curiously its spectral shapes more closely resemble the spectral shapes of specular reflection than those of the attenuated total reflectance method. We think that this phenomenon may be attributed to incorrect assignment due to optical effects. Since the problem in polymers seems to relate somewhat to their higher-order structure and orientation, we prepared a molding plate sample in which the flow of the melt can easily be imagined. We investigated how the spectral features changed from the gate position, in addition to observing the scanning electron microscopy (SEM) images. Furthermore, we applied the specular reflection method to avoid changes in the morphology resulting from pretreatment before the IR measurement. When we used the SEM images, we found cellular structures on the surface. Thus, as a first step, we would like to research the relation between the cellular structures and IR spectral shapes to consider the problems of POM.

 

Can you please briefly describe the method used in your investigation?

Considering the change in orientation by the specular reflection method, it is necessary to rotate the polarizer and perform a reflection measurement at each site. Analysis of the spectra obtained in this way revealed that there is a region where the real part of the dielectric function (RPDF) is greatly negative in the main chain direction of the molecule. We also found that the strange peaks found in earlier work in other laboratories coincided with the wavenumber range where the RPDF intersects with zero, and I thought that it was a polariton due to the delay effect of electromagnetic wave. To confirm this hypothesis, we assembled an experimental setup to observe the Berreman effect; namely, we performed reflection measurements of a thin film on a metal plate with a large incident angle. The Berreman effect should be observed as a reflection response in p-polarization only at the position of the LO mode.

 

What was innovative about your approach?

Since the spectrum would change greatly when the sample was stretched or compressed, we needed to investigate the relationship between the spectrum change and the morphology or orientation under slightly changed conditions. Thus, it is appropriate to discuss the IR spectra as a function of the gate position within one injection-molded plate. Usually, the IR spectrum should be considered to reflect the local structural vibration in organic materials; therefore, its relation to morphology has not usually been discussed. We think that there are few approaches that avoid preprocessing in the IR spectrum measurement and examining the relationship between IR spectra and SEM images.

 

Can you describe some of the challenges involved in sample preparation for your investigation?

To consider the morphology and chemical structure of the polymer, it is necessary to analyze samples nondestructively. It is therefore necessary to measure as much as possible without pretreatment. In observing the morphology, we had a problem with sputtering of Pt on the sample surface, which prevented charge-up. Also, since the morphology slightly changes while irradiating the electron beam, we had to carefully determine the irradiation conditions to avoid damage.

 

What conclusions did you draw from the study and why are they significant?

So far, polaritons have been observed in inorganic ion crystals and polar semiconductors, and there have been no reports that surface phonon polaritons have been observed in polymers. Although POM is a crystalline polymer, it seems surprising that polaritons appear in weak ordered materials like polymers. Furthermore, we pointed out that we face the risk of misinterpreting the measured spectra obtained by the destructive techniques in the framework of the ordinary vibration analysis. Therefore, it is necessary to reconsider the interpretation of large peaks in polymers in connection with higher-order structures. Thus, IR spectroscopy has potential for use when investigating the higher-order structures of polymers. In addition, we show that polar polymers with high flexibility can also be candidates as materials for low-loss nanophotonic devices that require structures generating surface phonon polaritons.

 

What are the next steps in your research?

We predict that a similar polariton mode will exist for polymers with a large dipole moment and relatively high-order structure. We would like to search for materials that behave similarly in polymers other than POM. Also, we will investigate the intermediate state that changes from ordinary vibrations to polaritons. Polymers are considered to be the most suitable materials to investigate the condition of changing from ordinary vibrations to polaritons in IR spectroscopy. Moreover, since it is believed that some IR peaks reflect higher-order structures, we would like to analyze such structures using finite-difference time-domain (FDTD) methods.

 

Reference

1.         N. Nagai, M. Okawara, and Y. Kijima, Appl. Spectrosc.70, 1278–1291 (2016).

 

 

 


Related to this article

The Ongoing Decline of Spectroscopy Expertise
In this panel discussion, five SpecAcademy instructors examined why spectroscopy expertise has declined and how SpecAcademy aims to rebuild it through curated, fundamentals-based education suited to increasingly complex analytical work.
The Mismatch Between Education and Industry
Panelists from the Society for Applied Spectroscopy, the Coblentz Society, Syensqo, Specac, and the University of Georgia discuss how a mismatch between academic curricula and industry practice leaves many analysts unsure when, and how, to use infrared and Raman spectroscopy.