Raman is a well-developed and implemented qualitative spectroscopic tool for molecular identification, but in recent years with the development of high resolution portable Raman spectrometers and cutting edge chemometric modeling, software has now enabled the use of Raman for highly precise quantitative measurements of mixtures and reactions.
Travis Thompson, Dawn Yang, and Robert Chimenti, B&W Tek, Inc.
Raman is a well-developed and implemented qualitative spectroscopic tool for molecular identification, but in recent years with the development of high resolution portable Raman spectrometers and cutting edge chemometric modeling, software has now enabled the use of Raman for highly precise quantitative measurements of mixtures and reactions. In this study, we have used B&W Tek's advanced chemometric modeling software BWIQ™ to determine unknown methanol concentrations in a tertiary mixture of methanol, acetonitrile, and water.
BWIQ is a multivariate analysis software package which can analyze spectral data and discover internal relationships between spectra and response data or spectra and sample classes. BWIQ combines traditional chemometric methods such as partial least squares regression (PLSR) and principal component analysis (PCA), with new methods such as adaptive iteratively reweighted penalized least squares (airPLS) algorithms for automatic baseline correction and support vector machine (SVM) algorithms for non-linear datasets.
For this study, the i-Raman® from B&W Tek, was chosen due to the fact that it is the highest resolution (~3 cm-1) portable Raman spectrometer on the market. This, in conjunction with its TE cooled CCD and convenient fiber optic probe, was coupled to the BCR100A double-pass cuvette holder.
Known methanol, acetonitrile, and water standards were prepared for development of a calibration curve using 10 mm disposable cuvettes. All measurements were taken under the following conditions: 532 nm excitation wavelength set to ~30 mW power output, and an integration time of 7.5 s. No averaging was used in this experiment and all spectra represent a single acquisition.
A total of 94 spectra were collected with varying concentrations of the three components. Once the data was collected, it was entered into BWIQ. Out of 94 total spectra entered in, 70 were randomly chosen for use in creating the calibration curve and the remaining 24 were used for validation. The data was then preprocessed by first conducting an airPLS baseline correction, then smoothing using the Sovitzky-Golay method, and taking a Sovitzky-Golay 1st differential. Finally, the calibration curve was created using PLS1 regression.
After applying preprocessing and regression to the data, the measured vs. predicted concentrations were plotted to determine the accuracy of the model. The R2 value was calculated to be greater than 0.999 for both the measured and predicted concentrations. Similarly, the RMSE was calculated to be less than 0.008 for both.
Lastly, samples were prepared with unknown methanol concentrations in a tertiary mixture of methanol, acetonitrile, and water. These samples were then measured by the i-Raman and fed into BWIQ, which successfully determined the concentration using the previously developed model.
From this experiment, we have shown that the i-Raman high resolution portable Raman spectrometer can be used with BWIQ to successfully develop a quantitative model to determine the concentration of methanol in tertiary mixtures of methanol, acetonitrile, and water, as shown in Figure 1. For more information please visit www.bwtek.com or call +1 (302) 368-7824.
Figure 1: Chemometric analysis workflow.
B&W Tek, Inc.
19 Shea Way, Newark, DE 19713
tel. (302) 368-7824; Fax: (302) 368-7830
Website: www.bwtek.com
The Effect of Heat Exposure on BPA and Phthalate Content in Commercial Bottled Water
May 8th 2024This study aimed to assess the levels of phthalates and bisphenol A (BPA) in various popular bottled waters compared to tap water. Additionally, it investigated whether exposure to high temperatures, akin to those in a car during summer, would elevate these levels. Using GC/MS analysis, samples were examined. Results showed that phthalates and BPA were either absent or well below safety thresholds in all bottled and tap water samples. Moreover, heating did not significantly affect phthalate concentrations, and BPA was undetectable in all samples.
Spex Speaks Science: Soil and Contamination
May 8th 2024The science and art of gardening and agriculture is part passion, part luck and a lot of chemistry. In this podcast, we will take a look at the science of soil and how chemistry can affect the growth and health of plants. We will also take a look at sources of potential contamination in gardens and how those contaminants can be tested and remediated. Hosted by Patricia Atkins, Manager, Global Product at Spex®.
The Analysis of Laboratory and Consumer Water Sources for the Presence of BPA and Phthalates
May 8th 2024Bottled water has evolved from a trendy luxury to a global consumer staple, with significant growth projected by 2012. In the U.S., consumption has soared, with safety concerns and substitution driving its popularity. Developing nations also rely on bottled water for safety. This study aims to address debated issues surrounding BPA and phthalate exposure in consumer water sources: 1. Are BPA and phthalates present in bottled water? 2. Does exposure to high temperatures increase leaching of BPA or phthalates? 3. Are levels in municipal or filtered water significantly different from bottled water?