Jasco, Inc.
The combination of an FTIR spectrometer with an optical microscope offers a valuable resource to investigate a variety of complex samples. There are a wide range of applications that have taken advantage of the attractive qualities of FTIR imaging systems including product development, biomedical research, forensics, polymers, and proteins.
Numerous methods for collecting the imaging data exist, many of them requiring expensive step-scan instruments in combination with a focal plane array (FPA) detector that involves sophisticated electronics for reading the multiple detector elements. An FTIR imaging system that is coupled with a linear array detector does not require a step-scan instrument but provides a fast and efficient analytical method to study various systems while collecting complete infrared spectra. FTIR imaging is used to describe the collection of a chemical profile of the sample area by expressing the intensity of a single absorption peak, or ratio of two absorption peaks, using an image "map".
Figure 1. Hair sample image with FTIR microscope.
Hair analysis can provide vital information concerning important chemicals that may be in the body. The presence of various toxins and nutrient deficiencies or abundances can be determined using this process. Infrared microscopy is one tool that can be used to examine the interior of the hair and differentiate passive contamination from drugs absorbed into the hair from ingestion. By slicing the hair specimen as either a cross section or laterally, infrared spectra can be obtained of the cortex and medulla of a single hair with a spatial resolution as high as 6.25 μm.
Figure 2. Infrared spectra of the medulla (green) and cortex (red).
A piece of hair was sliced using the HW-1 Multi-Angle SliceMaster and the sample was embedded into a KBr crystal for measurement. A 100 × 100 μm area was imaged with a JASCO FT/IR-6100 integrated with the IMV-4000 imaging microscope. An instrument resolution of 16 cm-1 was used to collect 32 scans for the single-beam background and sample spectra. Complete infrared spectra with a spectral range from 4000–750 cm-1 were collected.
Figure 3. Infrared image of percent alpha helix (left) and beta sheet (right) distribution.
Initial investigation of the hair sample found that there is a greater amount of lipid content in the medulla while primarily protein exists in the cortex of the hair sample. When the spectral data is input into the Secondary Structure Estimation software, it is found that a higher amount of alpha helix is present in the cortex while there is more beta sheet found in the medulla portion.
Infrared imaging was able to identify the different components of a hair specimen and also provide information concerning distribution of the secondary structures of the proteins present in the hair sample.
Jasco, Inc.
8649 Commerce Drive, Easton, MD 21601
Tel. (800) 333-5272
Single Cell and Microplastic Analysis by ICP-MS with Automated Micro-Flow Sample Introduction
April 25th 2024Single cell ICP-MS (scICP-MS) is increasingly seen as a powerful and fast tool for the measurement of elements in individual cells, mainly due to the high sensitivity and selectivity of ICP-MS. Analysis is performed in the same way as single nanoparticle (spICP-MS) analysis, which has become a well-established technique for the analysis of nanoparticles and particles.
Hot News on Agilent LDIR, New Developments, and Future Perspective
April 25th 2024Watch this video featuring Darren Robey and Dr. Wesam Alwan from Agilent Technologies to gain insights into the future trends shaping microplastics research and the challenges of their characterization. Discover the essential components necessary for accurate microplastics analysis and learn how the Agilent 8700 LDIR system addresses these challenges. Offering rapid and precise analysis capabilities, along with easy sample preparation methods that minimize contamination, the Agilent 8700 LDIR system is at the forefront of advancing microplastics research.
Accurate and robust analysis of challenging environmental samples for regulatory compliance
April 25th 2024This application note discusses how the adverse effects of sample matrix can be circumvented with an analytical workflow that includes robust ICP-MS instrumentation offering comprehensive yet simplified analysis of samples containing high dissolved solids such as soil digests, wastewater and solid wastes. The data presented in this application note was generated over 12 hours with over 160 samples covering soil extracts and a variety of water samples.
Analysis of drinking water in compliance with EPA Method 200.8, Revision 5.4
April 25th 2024This application note describes the analytical workflow developed for the analysis of water samples over an extended period using the latest innovations in ICP-MS instrumentation. The innovations specifically highlighted in this app note are the next generation Argon Gas Dilution accessory, which simplifies the analysis of high matrix samples allowing direct analysis without prior manual diution; the HAWK consumables and maintenance assistant within the Qtegra ISDS software; the new Easy-click compact (ECC) peristaltic pump; and the new Thermo Scientific autosampler, the iSC-65 autosampler.