The long anticipated PX4 Digital Pulse Processor from Amptek has joined the successful XR-100 family of X-ray detectors (as shown in Figure 1). The system allows for XRF analysis in the field and satisfies QC requirements for monitoring detector performance. The PX4 is also a powerful research tool that can be used to optimize detector performance.
As shown in Figure 2, the detection of lead (Pb) is an easy task for this pair of instruments. The L lines are easily resolved within 1 minute of unit power-on. Since the PX4 is driven by software, only one switch exists on the box (power). Everything else is software selectable and can be set to automatically load on startup. This ensures consistent, fast, and easy operation.
Figure 1. PX4 Digital Pulse Processor and XR-100CR X-ray Detector.
Since the PX4 has 24 programmable peaking times between 0.8 and 102 µs, it is well suited for a wide variety of applications. In addition, the determination of Resolution vs. Peaking Time (finding the noise corner), as in Figure 3, can be performed automatically by a software routine. With this information, the user can easily select the appropriate peaking time to maximize performance for the particular application, whether it be the best resolution, higher throughput, or a trade-off between the two.
Figure 2. Lead (Pb) Spectrum.
XRF measurements used to involve costly, liquid nitrogen dependent, instrumentation. Amptek has broken another barrier in offering a low cost, easy to use system that not only performs the measurements, but also characterizes the system to satisfy QC requirements and to optimize performance across a wide range of applications.
Figure 3. Resolution vs. Peaking Time.
Amptek, Inc.
6 De Angelo Drive, Bedford, MA 01730
Tel. (781) 275-2242, Fax (781) 275-3470
Single Cell and Microplastic Analysis by ICP-MS with Automated Micro-Flow Sample Introduction
April 25th 2024Single cell ICP-MS (scICP-MS) is increasingly seen as a powerful and fast tool for the measurement of elements in individual cells, mainly due to the high sensitivity and selectivity of ICP-MS. Analysis is performed in the same way as single nanoparticle (spICP-MS) analysis, which has become a well-established technique for the analysis of nanoparticles and particles.
Hot News on Agilent LDIR, New Developments, and Future Perspective
April 25th 2024Watch this video featuring Darren Robey and Dr. Wesam Alwan from Agilent Technologies to gain insights into the future trends shaping microplastics research and the challenges of their characterization. Discover the essential components necessary for accurate microplastics analysis and learn how the Agilent 8700 LDIR system addresses these challenges. Offering rapid and precise analysis capabilities, along with easy sample preparation methods that minimize contamination, the Agilent 8700 LDIR system is at the forefront of advancing microplastics research.
Accurate and robust analysis of challenging environmental samples for regulatory compliance
April 25th 2024This application note discusses how the adverse effects of sample matrix can be circumvented with an analytical workflow that includes robust ICP-MS instrumentation offering comprehensive yet simplified analysis of samples containing high dissolved solids such as soil digests, wastewater and solid wastes. The data presented in this application note was generated over 12 hours with over 160 samples covering soil extracts and a variety of water samples.
Analysis of drinking water in compliance with EPA Method 200.8, Revision 5.4
April 25th 2024This application note describes the analytical workflow developed for the analysis of water samples over an extended period using the latest innovations in ICP-MS instrumentation. The innovations specifically highlighted in this app note are the next generation Argon Gas Dilution accessory, which simplifies the analysis of high matrix samples allowing direct analysis without prior manual diution; the HAWK consumables and maintenance assistant within the Qtegra ISDS software; the new Easy-click compact (ECC) peristaltic pump; and the new Thermo Scientific autosampler, the iSC-65 autosampler.