Ultrafast Laser Diagnostics

Author(s)Avantes

Even though no current electronics is fast enough to measure femtosecond lasers, an estimation of the pulse duration, peak wavelength, and relative intensity is possible.

Even though no current electronics is fast enough to measure femtosecond lasers, an estimation of the pulse duration, peak wavelength, and relative intensity is possible.

The femtosecond time scale is out of reach for even the fastest electronics, so to perform pulse diagnostics other measurement techniques need to be used.

The AvaSoft-Femto add-on turns your Avantes spectrometer into a femtosecond laser diagnostic tool that can provide you with an estimation of the transform limited pulse duration as well as measuring the peak wavelength and relative intensity of the laser output. Using the add-on users can also easily export the measurements to spread sheet programs like Microsoft Excel for record keeping or further analysis.

Many femtosecond mode-locked lasers can generate nearly bandwidth-limited pulses, especially when they are based on soliton mode locking. A femtosecond mode-locked Ti:Sapphire laser when fully optimized propagates a soliton-like pulse with a hyperbolic secant squared function intensity distribution in the frequency domain.

Figure 1: An AvaSpec-2048L is used for femtosecond laser measurements.

By accurately measuring the spectral output of a femtosecond mode-locked Ti:Sapphire and using the time-bandwidth product of different pulse shapes (Gaussian, Hyperbolic Secant Squared, Lorentzian) the lower limit for the pulse duration can be determined.

FWHM Measurement

The full-width at half maximum (FWHM) is accurately measured using an Avantes spectrometer and this is then used in combination with a value of K (that is dependent on the symmetrical shape of the pulse) to calculate the transform limited pulse duration;

ΔvΔt≥K

The AvaSoft-Femto software allows for a quick and convenient way to show the transform limited pulse duration according to the pulse shape selected in the software. The complete Femto package also provides a good general purpose spectrometer that can be used for various applications in the lab.

Table I: Values for K depending on the pulse shape.

When using AvaSoft-Femto with an Avantes spectrometer that doesn't have an order sorting filter installed, you can also use the system to measure laser lines in the ~300–600 nm range by observing them in the second order. This means 500 nm will show up as 1000 nm on the spectrometer. Lines in the ~200–300 nm range can be seen in the third order (that is, 300 nm will show up at 900 nm on the spectrometer). The spectrometer included in the Ava-Femto package can be used for second and third order measurements.

Typical Configuration for AvaSoft-Femto

The AvaSoft-Femto can be used with virtually any existing Avantes spectrometer provided it covers the required wavelength range.

Avantes

Oude Apeldoornseweg 28, 7333 NS Apeldoorn, The Netherlands

tel. +31 313 670 170

Email: info@avantes.com; Website: www.avantes.com

Articles in this issue

almost 13 years ago

PIKE Technologies

almost 13 years ago

Amptek, Inc.

almost 13 years ago

Ocean Optics

almost 13 years ago

Photonis USA

almost 13 years ago

Shimadzu Scientific Instruments

almost 13 years ago

Milestone, Inc.

almost 13 years ago

Savillex Corporation

almost 13 years ago

WITec GmbH

Related to this article

Ingots of pure copper or pink gold on a black background. | Image Credit: Phawat - stock.adobe.com
At SciX, Kevin Wilkinson of the Universite de Montreal explains how faster data acquisition and new software have cut analysis time and how a particle’s chemical composition can link arsenic-bearing emissions back to a copper refinery’s processes.
Spectral Frontiers: Seeing the Unseeable Microspectroscopy
Microspectroscopy, the marriage of spectroscopic chemical identification with microscopic spatial resolution, has advanced from Perkin-Elmer's first commercial infrared microspectrometer in 1953 to today's nanoscale AFM-IR probes, synchrotron-brightness infrared beamlines, and compact hyperspectral tissue imaging devices being developed for AI-assisted cancer detection.
Richard Crocombe
The New York / New Jersey Section of the Society for Applied Spectroscopy will present its 2026 Gold Medal Award to Richard Crocombe at the Eastern Analytical Symposium on November 17, recognizing two decades of work that helped carry spectroscopy out of the laboratory and into the field.