An Examination of Comparing Two Chemometric Methods For the Generation of Prediction Rules: A Recent Study

Author(s)Will Wetzel

A recent study examined two chemometric methods for generating prediction rules.

In chemometric analysis, spectroscopists work with data to generate both quantitative and qualitative predictions to solve regression and classification problems. To accomplish this task effectively, analysts need to know how to run statistical tests for comparing the predictive performance of two or more prediction rules. According to author Tom Fearn of the University College London, there have been cases where claims have been made in papers that use chemometric analysis ineffectively to support flimsy claims (1). His paper, published in the Journal of Chemometrics, describes a few statistical tests that allow the analyst to compare the predictive performance of at least two, if not more, prediction rules (1).

Chemometrics, a field at the intersection of chemistry, statistics, and mathematics, often involves developing methods to generate analyte prediction rules. These rules convert raw spectroscopic or chromatographic data into meaningful analyte predictions, either as quantitative (regression) or qualitative (classification) predictions (1). Fearn's research highlights the importance of rigorously testing these rules to ensure that any claimed improvements in predictive accuracy are statistically significant and not mere artifacts of overfitting or other biases (1). Because chemometrics has been fused with multivariate and high-dimensional statistics, Fearn’s examination of prediction rules takes on greater significance (2).

Read More: Data Transforms in Chemometric Calibrations, Part 4A: Continuous-Wavelength Spectra and Discrete-Wavelength Models

Fearn’s study focuses on the distinction between a method and a prediction rule. Methods like partial least squares regression (PLSR) or linear discriminant analysis (LDA) are general approaches, whereas a prediction rule is a specific, fixed recipe derived from these methods to convert input data into predictions (1).

In the paper, Fearn addresses a common scenario in chemometrics research: the development of a new prediction method that is claimed to outperform existing ones. Often, the difference in performance is modest, making it essential to apply statistical tests to ensure these differences are not overstated (1). Fearn's work provides a comprehensive guide to these tests, enabling researchers to implement them without needing to delve into complex statistical literature (1).

Fearn’s paper is organized into two main sections. One section examines quantitative predictions, and the other explores qualitative predictions. In both, he discusses two primary validation approaches: using a separate test set and cross-validation. The validity of these comparisons hinges on ensuring that the samples used for prediction have not been seen during the training phase (1). This prevents overfitting, where a model performs well on training data but poorly on new, unseen data. Fearn recommended an approach for quantitative analysis in which bias and variance are tested separately, which can help compare variances allowing for correlation between two sets of errors (3).

Fearn also cautioned against a common pitfall in predictive modeling: using the same data for both tuning and comparing prediction rules. This can lead to misleadingly favorable results for more complex methods with more adjustable parameters, which can adapt too closely to the training data (1). To avoid this, Fearn stresses the importance of using genuinely unseen validation or test samples for final performance comparisons (1).

The practical implications of this research are significant for the chemometrics community. By following the statistical tests and validation procedures outlined by Fearn, researchers can more reliably compare prediction rules, leading to more robust and trustworthy advancements in the field. This work not only helps in distinguishing meaningful improvements from statistical noise, but it also promotes best practices in the development and assessment of predictive models.

References

(1) Fearn, T. Testing Differences in Predictive Ability: A Tutorial. J. Chemom. 2024, ASAP. DOI: 10.1002/cem.3549

(2) Wu, W.; Herath, A. Chemometrics and Predictive Modelling. In Nonclinical Statistics for Pharmaceutical and Biotechnology Industries. Zhang, L., Eds. Statistics for Biology and Health. Springer: Cham, 2016. DOI: 10.1007/978-3-319-23558-5_25

(3) Fearn, T. Comparing Standard Deviations. NIR News 1996, 7 (5), 5–6.


Related to this article

Curated 2026 Evergreen Content from Spectroscopy. ©  Chanakarn -chronicles-stock.adobe.com
Spectroscopy's editors gather 143 evergreen articles from 2026, including tutorials, terminology guides, technique reviews, application surveys, peer-reviewed research and the magazine's long-running columns, and organize them by subject so readers can build lasting knowledge one topic at a time.
Spectral Frontiers: Seeing the Unseeable Microspectroscopy
Microspectroscopy, the marriage of spectroscopic chemical identification with microscopic spatial resolution, has advanced from Perkin-Elmer's first commercial infrared microspectrometer in 1953 to today's nanoscale AFM-IR probes, synchrotron-brightness infrared beamlines, and compact hyperspectral tissue imaging devices being developed for AI-assisted cancer detection.