Tanta University recently published a review article that highlighted the versatility of metal complexes in analytical chemistry. We recap their research here.
Metal complexes can help detect and measure analytes. As a result, they are playing a more important role in analytical chemistry. A recent review article that was published in Coordination Chemistry Reviews explored this topic. The review article, written by a team of four researchers from Tanta University—Rehab H. Elattar, Samah F. El-Malla, Amira H. Kamal, and Fotouh R. Mansour—spotlighted the various applications in analytical chemistry where metal complexes are being applied (1).
Because of their distinct molecular geometries, metal complexes possess characteristics such as strong chromophore activity, luminescent structures, and electrochemical activity (1,2). These features enable the detection of analytes that might otherwise be difficult to measure, including those lacking chromophoric, fluorophoric, or oxidizable/reducible groups (1).
Brilliant background with a silver gradient and metallic texture effect. Vector illustration with bright patches of polished metal. | Image Credit: © SvetlanaWSE - stock.adobe.com
Metal complexes can enhance detection techniques like ultraviolet–visible (UV-vis) spectroscopy, spectrofluorometry, electrochemistry, and capillary electrophoresis (CE), which span both spectroscopy and chromatography applications. These methods are crucial for identifying analytes such as drugs, metals, nucleic acids, and both small and large molecules (1). By exploiting the interaction between metal complexes and analytes, researchers can achieve high levels of sensitivity and selectivity, leading to more accurate and reliable measurements (1).
In the review article, the authors explain that metal complexes are often used in applications where traditional detection methods struggle. For instance, the researchers discussed how metal complexes enable the measurement of non-chromophoric or non-fluorophoric compounds, which are typically challenging to detect using standard techniques (1). By forming interactions such as electrostatic, hydrophobic, and hydrogen bonding with the analytes, metal complexes can induce measurable changes in properties like UV-vis absorption spectra, facilitating their detection (1).
The review article also dedicates time to discussing fluorescence spectroscopy and the role metal complex-based analytical methods have in conjunction with the technique. When they are used in fluorescence-based sensing, metal complexes offer a cost-effective, highly sensitive, and selective approach for detecting various analytes, including cations, anions, and both chiral and achiral molecules (1). This versatility allows them to be customized for specific detection needs, making them a potent tool in fields ranging from environmental analysis to pharmaceuticals (1).
The authors also talk about how metal complexes can be integrated into “switch on” or “switch off” sensing strategies, which allow for easy detection of analytes (1). Because of this ability, metal complexes have been used for on-site analysis in substitute of traditional laboratory techniques, especially ones that are not portable.
Beyond detection, metal complexes also play a crucial role in sample preparation techniques. The review highlights their use in methods like displacement-dispersive liquid–liquid microextraction (D-DLLME) and solid-phase extraction (SPE) (1). These techniques, which are essential for isolating analytes from complex sample matrices, benefit from the high selectivity and efficiency that metal complexes offer through precise molecular interactions (1). This ensures that even trace levels of analytes can be accurately extracted and measured, enhancing the overall performance of analytical methods.
Additionally, metal complexes form the basis for developing chemosensors, which are used to detect a wide array of analytes. These sensors, by inducing changes in UV-vis absorption spectra, enable sensitive and selective detection, further broadening the applications of metal complexes in analytical chemistry (1).
Learn More: Chemosensors in Spectroscopy
Although metal complexes have their place in spectroscopy and chromatography, challenges also remain with their implementation. For example, temperature variations can affect quenching mechanisms in fluorescence-based sensors, complicating result interpretation (1). Additionally, the incorporation of multiple ligands in metal complexes may introduce complexities that require careful optimization for specific sensing applications (1).
This review article from the research team at Tanta University shows how the unique chemical properties of metal complexes make them valuable for detecting challenging analytes and improving analytical methods. As researchers continue to explore their potential, metal complexes are expected to play an even more prominent role in advancing fields such as environmental science, pharmaceuticals, and biochemistry (1).
Get essential updates on the latest spectroscopy technologies, regulatory standards, and best practices—subscribe today to Spectroscopy.
How Analytical Chemists Are Navigating DOGE-Driven Funding Cuts
July 14th 2025DOGE-related federal funding cuts have sharply reduced salaries, lab budgets, and graduate support in academia. Researchers view the politically driven shifts in priorities as part of recurring systemic issues in U.S. science funding during administrative transitions. The impact on Federal laboratories has varied, with some seeing immediate effects and others experiencing more gradual effects. In general, there is rising uncertainty over future appropriations. Sustainable recovery may require structural reforms, leaner administration, and stronger industry-academia collaboration. New commentary underscores similar challenges, noting scaled-back graduate admissions, spending freezes, and a pervasive sense of overwhelming stress among faculty, students, and staff. This article addresses these issues for the analytical chemistry community.
How Spectroscopy Drones Are Detecting Hidden Crop Threats in China’s Soybean Fields
July 8th 2025Researchers in Northeast China have demonstrated a new approach using drone-mounted multispectral imaging to monitor and predict soybean bacterial blight disease, offering a promising tool for early detection and yield protection.
Advancing Deep Soil Moisture Monitoring with AI-Powered Spectroscopy Drones
July 7th 2025A Virginia Tech study has combined drone-mounted NIR hyperspectral imaging (400 nm to 1100 nm) and AI to estimate soil moisture at root depths with remarkable accuracy, paving the way for smarter irrigation and resilient farming.
New Ecofriendly Spectrophotometric Method Boosts Accuracy in Veterinary Drug Analysis
June 30th 2025A recent study showcases a cost-effective, ecofriendly UV spectrophotometric method enhanced with dimension reduction algorithms to accurately quantify veterinary drugs dexamethasone and prednisolone, offering a sustainable alternative to traditional analysis techniques.
Toward a Generalizable Model of Diffuse Reflectance in Particulate Systems
June 30th 2025This tutorial examines the modeling of diffuse reflectance (DR) in complex particulate samples, such as powders and granular solids. Traditional theoretical frameworks like empirical absorbance, Kubelka-Munk, radiative transfer theory (RTT), and the Hapke model are presented in standard and matrix notation where applicable. Their advantages and limitations are highlighted, particularly for heterogeneous particle size distributions and real-world variations in the optical properties of particulate samples. Hybrid and emerging computational strategies, including Monte Carlo methods, full-wave numerical solvers, and machine learning (ML) models, are evaluated for their potential to produce more generalizable prediction models.
New Spectroscopy Methods Target Counterfeit Oral Medication Syrups
June 23rd 2025Researchers at Georgia College and Purdue University have developed a fast, low-cost method using Raman and UV–visible spectroscopy combined with chemometric modeling to accurately screen and quantify active ingredients in over-the-counter oral syrups, helping to fight counterfeit medications.