SPEC PerkinElmer 11.10
|Articles|December 1, 2012

Spectroscopy

  • Spectroscopy-12-01-2012
  • Volume 27
  • Issue 12

Hamamatsu Corporation

Hamamatsu Corporation

Company Description

Hamamatsu Corporation is the North American subsidiary of Hamamatsu Photonics K.K. (Japan), a leading manufacturer of devices for the generation and measurement of infrared, visible, and ultraviolet light. These devices include photodiodes, photomultiplier tubes, scientific light sources, infrared detectors, photoconductive detectors, and image sensors. The parent company is dedicated to the advancement of photonics through extensive research. This corporate philosophy results in state-of-the-art products that are used throughout the world in scientific, industrial, and commercial applications.

Chief Spectroscopic Techniques Supported

  • UV–visible spectroscopy

  • IR spectroscopy

  • Raman spectroscopy

  • Mass spectrometry

  • Atomic absorption spectroscopy

Markets Served

Hamamatsu provides high performance devices for analytical instruments. These include detectors and light sources for use in UV–vis, NIR, Raman, TOF-MS, and other spectrometers. We also provide miniature spectrometers for medical and biological research, environmental monitoring, production and process control, semiconductor inspection, chromatography, food analysis, water content measurement, and other industries.

Major Products/Services

  • Detectors: photomultiplier tubes, infrared detectors, photodiodes, and microchannel plates

  • Image sensors: NMOS, CMOS, InGaAs photodiode arrays, and CCD

  • Miniature spectrometers: UV–vis, NIR, and Raman

  • Light sources: xenon lamps, xenon flash lamps, deuterium lamps, laser diodes, and quantum cascade lasers

Facility

Hamamatsu Corporation is a wholly owned subsidiary of Hamamatsu Photonics K.K. (Japan). Hamamatsu Corporation's headquarters is located in Bridgewater, New Jersey. In addition, we have engineers located throughout the United States to provide you with technical and sales support.

Hamamatsu Corporation

360 Foothill Road

Bridgewater, NJ 08807

TELEPHONE

(908) 231-0960

FAX

(908) 231-1539

E-mail

usa@hamamatsu.com

WEB SITE

sales.hamamatsu.com

Articles in this issue

almost 14 years ago

Agilent Technologies

almost 14 years ago

EDAX Inc.

almost 14 years ago

Moxtek, Inc.

almost 14 years ago

Glass Expansion

almost 14 years ago

PANalytical, Inc.

almost 14 years ago

Shimadzu Scientific Instruments

almost 14 years ago

Rigaku Corporation

almost 14 years ago

Amptek, Inc

almost 14 years ago

Ocean Optics

almost 14 years ago

International Crystal Laboratories

Related to this article

Monitoring Sugar Consumption and Ethanol Production During Yeast Fermentation Using a Raman Plate Reader and Multivariate Analysis
This column shows that a Raman plate reader paired with partial least squares regression can simultaneously quantify glucose, fructose, sucrose, and ethanol in yeast fermentation samples, using turbidity-matched calibration standards to correct for yeast-induced turbidity, and offers a rapid, label-free, high-throughput method for tracking sugar consumption and ethanol production in strain screening, media optimization, and process development.
Highly Substituted Benzene Rings—The Rest of the Story II: Spectra
This column, the second installment on highly substituted benzene rings, shows that tri- and tetra-substituted substitution patterns can be distinguished by whether the ring bending peak is present and by the position of the in-phase aryl C-H wagging peak, which shifts according to how many adjacent hydrogens the ring carries.
Healthcare administrator reviewing an insurance policy schedule with a stethoscope on a clipboard, health insurance coverage, medical underwriting, prior authorization, and patient claims processing. | Image Credit: Joi_studio - stock.adobe.com
In a SciX interview, Marc Porter covered a lot of ground, from a student-driven pivot into immunoassays to a baseball analogy for Stokes and anti-Stokes scattering, and shares the open questions he is still chasing.