SPEC PerkinElmer 11.10
|Articles|December 1, 2014

Spectroscopy Supplements

  • Special Issues-12-01-2014
  • Volume 29
  • Issue 12

Hamamatsu Corporation

Company Description

Hamamatsu Corporation is the North American subsidiary of Hamamatsu Photonics K.K. (Japan), a leading manufacturer of devices for the generation and measurement of infrared, visible, and ultraviolet light, as well as X-rays. These devices include photodiodes, silicon photomultipliers, photodiode arrays (image sensors), infrared detectors, ion detectors, photomultiplier tubes, scientific light sources, and modular spectrometers. The parent company is dedicated to the advancement of photonics through extensive research. This corporate philosophy results in state-of-the-art products which are used throughout the world in scientific, industrial, and commercial applications.

Chief Spectroscopic Techniques Supported

  • Atomic absorption spectroscopy

  • IR spectroscopy

  • Mass spectrometry

  • UV-visible spectroscopy

  • X-ray spectroscopy

Markets Served

Hamamatsu provides high performance components for analytical instruments. These components include detectors and light sources for use in UV-vis, NIR, Raman, TOF-MS, and other spectrometers. We also provide modular spectrometers for medical and biological research, environmental monitoring, production and process control, semiconductor inspection, chromatography, food analysis, water content measurement, and other industries.

Major Products/Services

  • UV-vis detectors: photodiodes, silicon photomultipliers, and photomultiplier tubes

  • IR detectors: InAs, InAsSb, InGaAs, InSb, MCT (HgCdTe), PbS, PbSe, and thermopiles

  • Ion detectors: microchannel plate assemblies and electron multiplier tubes

  • X-ray detectors: photodiodes, silicon photomultipliers, photomultiplier tubes, and cameras

  • Photodiode arrays (image sensors): CCD, CMOS, NMOS, and InGaAs

  • Modular spectrometers: UV-vis absorption, NIR, Raman, fluorescence, and MEMS-FTIR

  • Light sources: xenon lamps, xenon flash lamps, deuterium lamps, hollow cathode lamps, laser diodes, and quantum cascade lasers

Facility

Hamamatsu Corporation is a wholly owned subsidiary of Hamamatsu Photonics K.K. (Japan). Hamamatsu Corporation's headquarters is located in Bridgewater, New Jersey. In addition, we have engineers located throughout the US to provide you with technical and sales support.

Hamamatsu Corporation
360 Foothill Road
Bridgewater, NJ 08807

TELEPHONE
(908) 231-0960

FAX
(908) 231-1539

E-MAILusa@hamamatsu.com

WEB SITEwww.hamamatsu.com


Related to this article

Monitoring Sugar Consumption and Ethanol Production During Yeast Fermentation Using a Raman Plate Reader and Multivariate Analysis
This column shows that a Raman plate reader paired with partial least squares regression can simultaneously quantify glucose, fructose, sucrose, and ethanol in yeast fermentation samples, using turbidity-matched calibration standards to correct for yeast-induced turbidity, and offers a rapid, label-free, high-throughput method for tracking sugar consumption and ethanol production in strain screening, media optimization, and process development.
Highly Substituted Benzene Rings—The Rest of the Story II: Spectra
This column, the second installment on highly substituted benzene rings, shows that tri- and tetra-substituted substitution patterns can be distinguished by whether the ring bending peak is present and by the position of the in-phase aryl C-H wagging peak, which shifts according to how many adjacent hydrogens the ring carries.
Healthcare administrator reviewing an insurance policy schedule with a stethoscope on a clipboard, health insurance coverage, medical underwriting, prior authorization, and patient claims processing. | Image Credit: Joi_studio - stock.adobe.com
In a SciX interview, Marc Porter covered a lot of ground, from a student-driven pivot into immunoassays to a baseball analogy for Stokes and anti-Stokes scattering, and shares the open questions he is still chasing.