A new dual-spectroscopy approach reveals real-time pollution threats in indoor workspaces. Chinese researchers have pioneered the use of laser-induced breakdown spectroscopy (LIBS) and aerosol mass spectrometry to uncover and monitor harmful heavy metal and dust emissions from soldering and welding in real-time. These complementary tools offer a fast, accurate means to evaluate air quality threats in industrial and indoor environments—where people spend most of their time.
A welder in protective gear fuses aluminum pieces with precision, © 69-chronicles-stock.adobe.com
A Breath of Fresh (or Not So Fresh) Air
As electronics manufacturing, repair, and small-scale welding become more common in indoor environments, the need to monitor what’s really in the air we breathe has never been more pressing. Recent studies by scientists in China shine a literal laser on the microscopic dangers floating in these enclosed spaces, particularly focusing on pollutants emitted during soldering and welding activities.
Using laser-induced breakdown spectroscopy (LIBS) and single-particle aerosol mass spectrometry (SPAMS), two complementary spectroscopic techniques, researchers have developed a rapid, real-time detection platform that identifies and tracks harmful airborne particles—especially heavy metals like lead (Pb) and tin (Sn), as well as carbon emissions and fine particulate matter (PM) (1,2).
LIBS + SPAMS: A Dual-Tech Air Quality Solution
In a 2025 study published in Spectrochimica Acta, Part B: Atomic Spectroscopy, researchers Nuerbiye Aizezi, Yanpeng Ye, Ziang Chen, and Yuzhu Liu from Nanjing University of Information Science & Technology used LIBS to directly monitor emissions from soldering operations. LIBS employs a high-energy Q-switched Nd: YAG laser (1064 nm) to create a plasma on airborne particles, producing emission lines that reveal the elements present—no sample prep required (1,2).
In an earlier complementary study published in Optics and Lasers in Engineering, Enlai Wan, Qihang Zhang, Lei Li, Qinhui Xie, Xuan Li, and again Yuzhu Liu combined LIBS with SPAMS to provide additional data such as isotopic composition and particle size distribution, offering a richer profile of the pollutants and their potential health impacts (2).
Together, these tools form a real-time monitoring system capable of assessing the nature, origin, and concentration of harmful aerosols, and were deployed to compare emissions from traditional lead-tin solder wire versus lead-free alternatives.
Temperature, Toxins, and Time
One of the most striking findings from Aizezi and colleagues was the clear link between soldering temperature and pollutant levels. LIBS revealed that as the soldering temperature rose, the evaporation rates of Pb and Sn increased sharply. The carbon spectral line intensity also rose, indicating elevated gaseous emissions, possibly from flux combustion or organic material degradation (1).
Fine particulate matter < 2.5 µm (PM2.5) and < 10 µm (PM10) showed significant increases at higher temperatures. Notably, PM2.5 took longer to reach peak concentration in workers’ breathing zones, suggesting prolonged exposure to the most dangerous particles. PM2.5 is well-known for its ability to penetrate deep into the lungs and enter the bloodstream (1).
Quantitative analysis reinforced the observational data: Pearson’s correlation coefficients for Pb and Sn exceeded 0.8, and principal component analysis (PCA) analysis returned an R² of 0.89, confirming a strong linear relationship between temperature and pollutant intensity (1).
The Human Factor: Why Indoor Air Matters
As the second study points out, people now spend over 70–90% of their time indoors, making indoor air quality more important than ever—especially in workplaces where electronics or metal fabrication is performed. Exposure to Pb and Sn fumes can cause immune suppression,respiratory inflammation, and long-term neurological damage, with children and elderly populations particularly at risk (2).
The combination of LIBS and SPAMS allows for the classification of different welding emissions using machine learning (ML), including principal component analysis (PCA) and back-propagationartificial neural networks (BP-ANN), which could pave the way for AI-based indoor pollution alerts (2).
Cleaner Air Through Smarter Monitoring
This research, conducted across two state-of-the-art Chinese research hubs—the State Key Laboratory Cultivation Base of Atmospheric Optoelectronic Detection and Information Fusion and the Jiangsu International Joint Laboratory on Meteorological Photonics and Optoelectronic Detection at Nanjing University of Information Science & Technology—underscores a critical shift in environmental monitoring: speed, accuracy, and real-time insight (1,2).
Compared with conventional tools like ion chromatography or X-ray fluorescence, the LIBS-SPAMS combo is faster, non-destructive, and more adaptable to evolving conditions (2,3).
As soldering and welding remain integral to industries and DIY hobbies alike, this work provides both a warning and a roadmap. By making the invisible visible, these tools offer a path to cleaner indoor air and safer work environments.
References
(1) Aizezi, N.; Ye, Y.; Chen, Z.; Liu, Y. Impact of Soldering Temperatures on Heavy Metal and Dust Emissions: A LIBS-Based Environmental Pollution Analysis. Spectrochim. Acta, Part B 2025, in press, 107124. DOI: 10.1016/j.sab.2025.107124
(2) Wan, E.; Zhang, Q.; Li, L.; Xie, Q.; Li, X.; Liu, Y. The Online In Situ Detection of Indoor Air Pollution via Laser-Induced Breakdown Spectroscopy and Single Particle Aerosol Mass Spectrometer Technology. Opt. Lasers Eng. 2024, 174, 107974. DOI: 10.1016/j.optlaseng.2023.107974
(3) Wetzel, W. Evaluating the Impact of ICP-MS and LIBS on Environmental Monitoring. 2024, September 23. https://www.spectroscopyonline.com/view/evaluating-the-impact-of-icp-ms-and-libs-on-environmental-monitoring (accessed 2025-04-18)
Get essential updates on the latest spectroscopy technologies, regulatory standards, and best practices—subscribe today to Spectroscopy.
New Study Expands Nickel Autoionization Spectra to Advance Laser Isotope Separation Technologies
July 17th 2025Researchers at China’s National Key Laboratory have identified 170 nickel autoionization states using resonance ionization mass spectrometry, significantly advancing the spectral database critical for laser isotope separation and atomic spectroscopy.
Laser Ablation Molecular Isotopic Spectrometry: A New Dimension of LIBS
July 5th 2012Part of a new podcast series presented in collaboration with the Federation of Analytical Chemistry and Spectroscopy Societies (FACSS), in connection with SciX 2012 — the Great Scientific Exchange, the North American conference (39th Annual) of FACSS.
High-Speed Immune Cell Identification Using New Advanced Raman BCARS Spectroscopy Technique
July 16th 2025Irish researchers have developed a lightning-fast, label-free spectroscopic imaging method capable of classifying immune cells in just 5 milliseconds. Their work with broadband coherent anti-Stokes Raman scattering (BCARS) pushes the boundaries of cellular analysis, potentially transforming diagnostics and flow cytometry.
AI-Powered Raman with CARS Offers Laser Imaging for Rapid Cervical Cancer Diagnosis
July 15th 2025Chinese researchers have developed a cutting-edge cervical cancer diagnostic model that combines spontaneous Raman spectroscopy, CARS imaging, and artificial intelligence to achieve 100% accuracy in distinguishing healthy and cancerous tissue.
How Analytical Chemists Are Navigating DOGE-Driven Funding Cuts
July 14th 2025DOGE-related federal funding cuts have sharply reduced salaries, lab budgets, and graduate support in academia. Researchers view the politically driven shifts in priorities as part of recurring systemic issues in U.S. science funding during administrative transitions. The impact on Federal laboratories has varied, with some seeing immediate effects and others experiencing more gradual effects. In general, there is rising uncertainty over future appropriations. Sustainable recovery may require structural reforms, leaner administration, and stronger industry-academia collaboration. New commentary underscores similar challenges, noting scaled-back graduate admissions, spending freezes, and a pervasive sense of overwhelming stress among faculty, students, and staff. This article addresses these issues for the analytical chemistry community.
New Study Expands Nickel Autoionization Spectra to Advance Laser Isotope Separation Technologies
July 17th 2025Researchers at China’s National Key Laboratory have identified 170 nickel autoionization states using resonance ionization mass spectrometry, significantly advancing the spectral database critical for laser isotope separation and atomic spectroscopy.
Laser Ablation Molecular Isotopic Spectrometry: A New Dimension of LIBS
July 5th 2012Part of a new podcast series presented in collaboration with the Federation of Analytical Chemistry and Spectroscopy Societies (FACSS), in connection with SciX 2012 — the Great Scientific Exchange, the North American conference (39th Annual) of FACSS.
High-Speed Immune Cell Identification Using New Advanced Raman BCARS Spectroscopy Technique
July 16th 2025Irish researchers have developed a lightning-fast, label-free spectroscopic imaging method capable of classifying immune cells in just 5 milliseconds. Their work with broadband coherent anti-Stokes Raman scattering (BCARS) pushes the boundaries of cellular analysis, potentially transforming diagnostics and flow cytometry.
AI-Powered Raman with CARS Offers Laser Imaging for Rapid Cervical Cancer Diagnosis
July 15th 2025Chinese researchers have developed a cutting-edge cervical cancer diagnostic model that combines spontaneous Raman spectroscopy, CARS imaging, and artificial intelligence to achieve 100% accuracy in distinguishing healthy and cancerous tissue.
How Analytical Chemists Are Navigating DOGE-Driven Funding Cuts
July 14th 2025DOGE-related federal funding cuts have sharply reduced salaries, lab budgets, and graduate support in academia. Researchers view the politically driven shifts in priorities as part of recurring systemic issues in U.S. science funding during administrative transitions. The impact on Federal laboratories has varied, with some seeing immediate effects and others experiencing more gradual effects. In general, there is rising uncertainty over future appropriations. Sustainable recovery may require structural reforms, leaner administration, and stronger industry-academia collaboration. New commentary underscores similar challenges, noting scaled-back graduate admissions, spending freezes, and a pervasive sense of overwhelming stress among faculty, students, and staff. This article addresses these issues for the analytical chemistry community.
2 Commerce Drive
Cranbury, NJ 08512