Market Profile: On-Line Ultraviolet 254-nm Water Analysis

Market Profile: On-Line Ultraviolet 254-nm Water Analysis

A growing niche among on-line water analysis instrumentation is UV254 probes, which provide photometric analysis of a specific ultraviolet (UV) wavelength. The technique makes it possible to provide real-time organics analysis that allows for improved control and lower costs for water treatment facilities.

Online UV254 analyzer vendor share - 2012.

The spectral absorbance or transmittance of water at 254 nm, which is in the middle of the UV spectrum, provides a strong measure of the concentration of natural organic matter (NOM). UV254 probes require no sample prep, no reactants, and provide direct continuous measurement of water flow. This, therefore, makes them good supplemental or even surrogate analyzers for on-line total organic carbon (TOC), biological oxygen demand (BOD), and other organics analyzers that are more complicated and more costly, although they provide more accurate measurements. The ability of UV254 probes to measure aromatic and reactive organics also makes the technique useful for dosing disinfectants and other chemicals in wastewater treatment plants so as to minimize the release of disinfectant by-products and to optimize the cost of such chemicals.

The market for on-line UV254 analyzers, which includes instruments that provide additional capabilities, should total around $12 million in 2012. Despite economic uncertainty in the US and a weakening economy in Europe, demand for UV254 should see modest near-term growth as water treatment facilities look to incorporate the simple and relatively inexpensive technique that can potentially offer significant operational savings.

The foregoing data were derived from research for SDi's upcoming market analysis and perspectives report entitled Environmental Analysis Instrumentation: Monitoring the Health of our Planet, January 2013. For more information, contact Stuart Press, Vice President, Strategic Directions International, Inc., 6242 Westchester Parkway, Suite 100, Los Angeles, CA 90045, (310) 641-4982, fax: (310) 641-8851, www.strategic-directions.com.

Articles in this issue

almost 14 years ago

Agilent Technologies

almost 14 years ago

EDAX Inc.

almost 14 years ago

Moxtek, Inc.

almost 14 years ago

Glass Expansion

almost 14 years ago

PANalytical, Inc.

almost 14 years ago

Shimadzu Scientific Instruments

almost 14 years ago

Rigaku Corporation

almost 14 years ago

Amptek, Inc

almost 14 years ago

Ocean Optics

almost 14 years ago

International Crystal Laboratories

Related to this article

Optical and Electronic Instrument Components,  ©  ridwan -chronicles-stock.adobe.com
The updated and expanded 2026 edition of Spectroscopy's Instrument Components Terminology Guide defines the sources, detectors, optical and dispersive elements, sampling hardware, physical constants, and unit conversions used across UV-vis, NIR, IR, Raman, X-ray, and atomic spectroscopic instrumentation, with new terms reflecting component developments reported between 2022 and 2026.
Pittsburgh, Pennsylvania, USA. Beautiful Pittsburgh at twilight. | Image Credit: © checubus - stock.adobe.com
Organized by CPACT, the April 27 to 29 meeting at the Marriott Pittsburgh City Center will bring together scientists, engineers, and vendors across the process industries, with keynotes on PAT, Raman, and NIR applications and an abstract deadline of December 7, 2026.