Register Now: Advances in Spectroscopy for Pharma and Biopharmaceutical Analysis Symposium
|Articles|February 1, 2020

Spectroscopy Supplements

  • Special Issues-02-01-2020
  • Volume 35
  • Issue 2

Introduction to the Raman Spectroscopy Terminology Guide

The enthusiastic responses to previous terminology guides has led the editors of Spectroscopy to develop a similar guide for Raman spectroscopy, initially focusing on those terms related to Raman and to molecular spectroscopy. Such a guide would include the types of Raman spectroscopy methods and many terms related to the various Raman techniques, basic nomenclature and concepts, data processing, instrumentation, and the many applications of Raman instruments. In addition, it would include some data and computer terms, some statistical data analysis terms, and the essential chemometric terms for typical data preprocessing and calibration. The Raman Terminology Guide you now have before you is a comprehensive set of definitions for topics of interest to molecular spectroscopists and those specifically using Raman spectroscopy in their daily work. This guide includes the types of Raman spectroscopy techniques and many terms related to the applications of Raman spectroscopy instruments. This terminology guide includesdefinitions for more than 250+ molecular spectroscopy terms in sufficient detail to provide readers with a reasonable understandingof the concepts covered. In addition to using this guide, spectroscopists may also wish to know the definitions given by various organizations for many spectroscopic terms; for these, one may refer to The ACS Style Guide, the American Society for Testing and Materials (ASTM) terminology guides, United States Pharmacopeia (USP) documents, or the International Union of Pure and Applied Chemistry (IUPAC) guidance documents.

This terminology guide is not intended to be highly theoretical, or all-inclusive in its coverage. For example, we have elected not to cover every possible term used in Raman spectroscopic instrumentation, measurement, data handling, and validation, nor to go too deep into theoretical or complex Raman phenomena. Instead, we have chosen to include most terms that may be encountered in everyday laboratory work where Raman and infrared spectroscopy are in general use. Terms included for Raman techniques are: Brillouin scattering, coherent anti-Stokes Raman spectroscopy (CARS), coherent Raman scattering, Breit-Wigner-Fano resonance, far-field Raman spectroscopy, Fermi resonance, hyperspectral imaging, plasmons, Raman effect, Raman intensity function, Raman rotationalspectroscopy, Raman vibrational spectroscopy, resonance Raman spectroscopy (RRS), shifted excitation Raman difference spectroscopy (SERDS), stimulated Raman, spatially offset Raman spectroscopy (SORS), spontaneous Raman spectroscopy, stimulated Raman spectroscopy (SRS), surface-enhanced Raman spectroscopy (SERS), surface-enhanced resonance Raman spectroscopy (SERRS), surface-enhanced spatially offset Raman spectroscopy (SESORS), surface plasmon polariton enhanced Raman spectroscopy(SPPERS), tip-enhanced Raman spectroscopy (TERS), and two-dimensional (2D) correlation spectroscopy. This glossary should be helpful to both novice and advanced users, serving as a useful reference to even the most experienced in the field.

Articles in this issue


Related to this article

Healthcare administrator reviewing an insurance policy schedule with a stethoscope on a clipboard, health insurance coverage, medical underwriting, prior authorization, and patient claims processing. | Image Credit: Joi_studio - stock.adobe.com
In a SciX interview, Marc Porter covered a lot of ground, from a student-driven pivot into immunoassays to a baseball analogy for Stokes and anti-Stokes scattering, and shares the open questions he is still chasing.
Highlights from What’s Nu October 2026
In this Q&A, we recap the October edition of “What’s Nu,” which covered topics such as how novel spectroscopic and analytical methods are transforming environmental monitoring, medical treatment, and accessibility in scientific research.
Spectroscopy Top 10 DOI Articles of the Month (October 2026)
The following articles are the most accessed digital object identifier (DOI) manuscripts for Spectroscopy and LCGC International during the month of October 2026. Nine articles are individually ranked here by DOI page views; the seventh-highest entry (99 views) was recorded against the bare LCGC North America journal-level DOI rather than an individual article and is therefore not attributable to a single manuscript.