Market Profile: Secondary Ion Mass Spectrometry

Although mass spectrometers are more commonly associated with life science applications, there are some mass spectrometry (MS) techniques that are specifically designed for surface science applications.

Although mass spectrometers are more commonly associated with life science applications, there are some mass spectrometry (MS) techniques that are specifically designed for surface science applications. One of the most prominent such techniques is secondary ion mass spectrometry (SIMS). Like most surface science techniques involving electron or ion optics, SIMS is carried out under vacuum conditions. An ion beam is directed at a spot on the surface of the sample, sputtering atoms off of the sample surface. These secondary ions are introduced into the mass spectrometer for analysis. Several options are commercially available for the mass analyzer, including single-quadrupole, time-of-flight, and magnetic-sector instruments. The mass analyzer provides the elemental composition of the sample directly beneath the ion beam. To build up a two-dimensional image of the surface, the ion beam is rastered across the sample. The ion beam can also be used to sputter away the sample layer by layer, allowing depth profile analysis.

SIMS market demand by industry for 2012.

SIMS is commonly used to analyze semiconductor materials and other materials used in electronics, such as data storage media. The sensitivity to the surface layer allows SIMS to analyze thin films that are deposited on these materials. SIMS is also used in research laboratories in both academic and government settings. Although materials analysis applications are common here, there are also some environmental applications in the analysis of particulate matter making up air pollution. The total market demand for SIMS amounted to less than $100 million in 2012.

The foregoing data were adapted and extracted from SDi's market analysis and perspectives report entitled Mass Spectrometry: Limitless Innovation in Analytical Science, October 2013. For more information, visit www.strategic-directions.com.


Related to this article

Ingots of pure copper or pink gold on a black background. | Image Credit: Phawat - stock.adobe.com
At SciX, Kevin Wilkinson of the Universite de Montreal explains how faster data acquisition and new software have cut analysis time and how a particle’s chemical composition can link arsenic-bearing emissions back to a copper refinery’s processes.
Spectral Frontiers: Seeing the Unseeable Microspectroscopy
Microspectroscopy, the marriage of spectroscopic chemical identification with microscopic spatial resolution, has advanced from Perkin-Elmer's first commercial infrared microspectrometer in 1953 to today's nanoscale AFM-IR probes, synchrotron-brightness infrared beamlines, and compact hyperspectral tissue imaging devices being developed for AI-assisted cancer detection.
Richard Crocombe
The New York / New Jersey Section of the Society for Applied Spectroscopy will present its 2026 Gold Medal Award to Richard Crocombe at the Eastern Analytical Symposium on November 17, recognizing two decades of work that helped carry spectroscopy out of the laboratory and into the field.