In a recent study out of Leiden University Medical Center and the University of Utrecht in the Netherlands, scientists developed a new system for analyzing antigen-specific antigen-binding fragments (Fab), to help better understand human autoantibodies. Their findings were later published in Nature Communications (1).
Antikörper und Viren | Image Credit: © peterschreiber.media - stock.adobe.com
Antibodies are vital in protecting a host organism from pathogens. To provide protection in specific and tunable ways, antibodies harbor highly variable regions in Fab. This variable domain is initially generated by recombining variable (V), diversity (D) and joining (J) gene segment; during this process, nucleotides are deleted, while palindromic and non-templated nucleotides are inserted at the junctions of the assembled gene segments. When combined with somatic hypermutation of the variable domain upon antigen encounter, these processes may create billions of unique antibodies, including various clones that can bind the same antigens. To prevent antibody formations that target the body itself, also known as autoantibodies, various tolerance mechanisms, which identify autoreactive B cell clones and exclude them via clonal deletion or variable domain editing, are employed.
If these tolerance mechanisms fail, this can ultimately lead to autoimmune diseases, which are currently estimated to affect approximately 1 in 10 individuals. As a result, there have been studies investigating how autoantibodies are associated with disease development, progression, or treatment. However, current insights into the extent of autoantibody repertoires are lacking, mostly due to the limitations of currently applied technologies. In response to this, the scientists introduced a liquid chromatography-mass spectrometry (LC-MS)-based Fab profiling approach for studying plasma antibody repertoires at the protein level with molecular resolution. This method selectively generates IgG1 Fab fragments from affinity enriched plasma IgG and analyzes Fab molecules via LC–MS. According to the scientists, this approach helps in “resolving the diversity of polyclonal antibody mixtures and repertoires based on the unique mass and retention time of each Fab molecule” (1).
When this approach was applied, it was revealed that plasma and virus-specific IgG1 repertoires are unique and polyclonal, with few clones showing particularly high abundances. This diversity against infectious agents may differ from those of autoreactive antibody repertoires because of the exclusion of autoreactive antibody clones by tolerance mechanisms, as well as the different nature of and context in which autoantigens may be recognized. The scientists also introduced in-depth autoantigen-specific Fab profiling and resolve an autoreactive plasma antibody sub-repertoire at the molecular level, using the prominent autoantibody response of anti-citrullinated protein antibodies (ACPA) as an example.
According to the scientists, each patient harbors a unique and diverse ACPA IgG1 repertoire, which is dominated by a few antibody clones. However, unlike total plasma IgG1 antibody repertoires, the ACPA IgG1 sub-repertoire can be characterized by an expansion of antibodies that can harbor Fab glycans and detect different glycovariants of the same clone. Altogether, the scientists’ data indicated that the autoantibody response in a prominent human autoimmune disease is complex, unique to each patient, and dominated by a relatively low number of clones. More research must be conducted, but this can potentially open way for similar studies and findings that can help prevent and fight autoimmune diseases.
(1) Stork, E. M.; van Rijswijck, D. M. H.; van Schie, K. A.; Hoek, M.; Kissel, T.; et al. Antigen-Specific Fab Profiling Achieves Molecular-Resolution Analysis of Human Autoantibody Repertoires in Rheumatoid Arthritis. Nat. Commun. 2024, 15, 3114. DOI: 10.1038/s41467-024-47337-x
Machine Learning and Optical Spectroscopy Advance CNS Tumor Diagnostics
July 1st 2025A new review article highlights how researchers in Moscow are integrating machine learning with optical spectroscopy techniques to enhance real-time diagnosis and surgical precision in central nervous system tumor treatment.
A Life Measured in Peaks: Honoring Alan George Marshall (1944–2025)
June 18th 2025A pioneer of FT-ICR Mass Spectrometry, Alan G. Marshall (1944–2025), is best known for co-inventing Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS), a transformative technique that enabled ultrahigh-resolution analysis of complex mixtures. Over a career spanning more than five decades at institutions like the University of British Columbia, The Ohio State University, and Florida State University, he published over 650 peer-reviewed papers and mentored more than 150 scientists. Marshall’s work profoundly impacted fields ranging from astrobiology to petroleomics and earned him numerous prestigious awards and fellowships. Revered for his intellect, mentorship, and dedication to science, he leaves behind a legacy that continues to shape modern mass spectrometry.
Machine Learning Accelerates Clinical Progress of SERS Technology
May 22nd 2025A new review in TrAC Trends in Analytical Chemistry by Alfred Chin Yen Tay and Liang Wang highlights how machine learning (ML) is transforming surface-enhanced Raman spectroscopy (SERS) into a powerful, clinically viable tool for rapid and accurate medical diagnostics.
Describing Their Two-Step Neural Model: An Interview with Ayanjeet Ghosh and Rohit Bhargava
May 20th 2025In the second part of this three-part interview, Ayanjeet Ghosh of the University of Alabama and Rohit Bhargava of the University of Illinois Urbana-Champaign discuss how machine learning (ML) is used in data analysis and go into more detail about the model they developed in their study.
Analyzing the Protein Secondary Structure in Tissue Specimens
May 19th 2025In the first part of this three-part interview, Ayanjeet Ghosh of the University of Alabama and Rohit Bhargava of the University of Illinois Urbana-Champaign discuss their interest in using discrete frequency infrared (IR) imaging to analyze protein secondary structures.