Surface-Enhanced Raman Scattering (SERS) Spectroscopy Used to Detect COVID-19 Virus

Author(s)Aaron Acevedo

Scientists from Duke University in Durham, North Carolina recently tested a surface-enhanced Raman scattering (SERS) spectroscopy system for detecting the SARS-CoV-2 virus. Their findings were published in Analytical Chemistry (1).

The COVID-19 pandemic caused an unprecedented need for rapid, sensitive, and cost-effective point-of-care diagnostic tests to prevent and mitigate the spread of the SARS-CoV-2 virus. Spectroscopy techniques can be used to detect the virus, protecting against the disease, and helping to screening for long COVID. For example, a study out of the Federal University of Sao Francisco Valley in Pernambuco, Brazil tested using visible or near-infrared (Vis-NIR) spectroscopy and machine learning algorithms to detect SARS-CoV-2 (2). Additionally, spectroscopy’s use to detect COVID-19 has been a hot topic at conferences. At SPIE Photonics West 2024 in TK PLACE, for example, Boris Mizaikoff of the University of Ulm discussed using breath analysis with used medical/N95 masks to detect long COVID-19 in patients. “Every time we put on a mask, we’re inhaling air, which means we’re trapping species from the outside world on the outside of the mask. When we’re exhaling, the inside [of the mask] is trapping everything we’re exhaling,” he said when explaining the sentiment behind this research (3).

Read More: Detecting Covid-19 Using Visible or Near-Infrared Spectroscopy and Machine Learning

In this study, the scientists demonstrated an advanced lateral flow immunoassay (LFIA) platform with dual-functional (colorimetric and surface-enhanced Raman scattering [SERS]) detection of the spike 1 (S1) protein of SARS-CoV-2. The nanosensor was integrated with a specially designed core–gap–shell morphology, made of a gold shell decorated with external nanospheres (with the structure being referred to as a gold nanocrown [GNC]). This structure was also labeled with a Raman reporter molecule of 1,3,3,1′,3′,3′-hexamethyl-2,2′-indotricarbocyanine iodide (HITC), so that a strong colorimetric signal and an enhanced SERS signal could be produced.

Read More: Screening for Long COVID Using Exhaled Breath Analysis

Among the different plasmonics-active GNC nanostructures, it was found that the GNC-2 morphology, which has a shell decorated with an optimum number and size of nanospheres, produces an intense dark-blue colorimetric signal and ultrahigh SERS signals. The limit of detection (LOD) of the S1 protein via colorimetric detection LFIA was determined to be 91.24 pg/mL. Compared to the SERS LFIA method, the LOD was found to be over three orders of magnitude lower at 57.21 fg/mL. Additionally, the performance of the GNC-2 nanosensor was analyzed regarding the direct analysis of the S1 protein spiked in saliva samples, albeit without prior sample pretreatment. With this approach, using SERS-based plasmonics-enhanced LFIA, the LOD was found to be as low as 39.65 fg/mL; these findings indicate ultrahigh detection sensitivity. With these findings, the scientists found that their GNC nanosensor exhibited excellent sensitivity, reproducibility, and rapid detection of the SARS-CoV-2 S1 protein. This all demonstrates the technique to have excellent potential as a point-of-care platform for the early detection of respiratory virus infections.

References

(1) Atta, S.; Zhao, Y.; Li, J. Q.; Vo-Dinh, T. Dual-Modal Colorimetric and Surface-Enhanced Raman Scattering (SERS)-Based Lateral Flow Immunoassay for Ultrasensitive Detection of SARS-CoV-2 Using a Plasmonic Gold Nanocrown. Anal. Chem. 2024, 96 (12), 4783–4790. DOI: 10.1021/acs.analchem.3c04361

(2) Acevedo, A. Detecting Covid-19 Using Visible or Near-Infrared Spectroscopy and Machine Learning. MJH Life Sciences 2023. https://www.spectroscopyonline.com/view/detecting-covid-19-using-visible-or-near-infrared-spectroscopy-and-machine-learning (accessed 2024-4-25)

(3) Acevedo, A. Screening for Long COVID Using Exhaled Breath Analysis. MJH Life Sciences 2024. https://www.spectroscopyonline.com/view/screening-for-long-covid-using-exhaled-breath-analysis (accessed 2024-4-25)


Related to this article

Spectroscopy Top 10 DOI Articles of the Month (October 2026)
The following articles are the most accessed digital object identifier (DOI) manuscripts for Spectroscopy and LCGC International during the month of October 2026. Nine articles are individually ranked here by DOI page views; the seventh-highest entry (99 views) was recorded against the bare LCGC North America journal-level DOI rather than an individual article and is therefore not attributable to a single manuscript.
Curated 2026 Evergreen Content from Spectroscopy. ©  Chanakarn -chronicles-stock.adobe.com
Spectroscopy's editors gather 143 evergreen articles from 2026, including tutorials, terminology guides, technique reviews, application surveys, peer-reviewed research and the magazine's long-running columns, and organize them by subject so readers can build lasting knowledge one topic at a time.
Healthcare administrator reviewing an insurance policy schedule with a stethoscope on a clipboard, health insurance coverage, medical underwriting, prior authorization, and patient claims processing. | Image Credit: Joi_studio - stock.adobe.com
In a SciX interview, Marc Porter covered a lot of ground, from a student-driven pivot into immunoassays to a baseball analogy for Stokes and anti-Stokes scattering, and shares the open questions he is still chasing.
Highlights from What’s Nu October 2026
In this Q&A, we recap the October edition of “What’s Nu,” which covered topics such as how novel spectroscopic and analytical methods are transforming environmental monitoring, medical treatment, and accessibility in scientific research.