|Articles|February 1, 2018

Application Notebook

  • Application Notebook-02-01-2018
  • Volume 33
  • Issue 1

TrueSurface—The Original Topographic Raman Imaging System

Author(s)WITec GmbH

Confocal Raman microscopy is a versatile, nondestructive and fast method for studying the chemical composition of living and non-living material. It is used to identify and localize not only the molecules in a specimen but also to detect their quantity, degree of crystallinity, and crystal symmetry.

However, not all samples have a flat and smooth surface. To acquire Raman images from samples with rough, inclined, or irregularly-shaped surfaces, WITec invented topographic Raman imaging.

With the TrueSurface™ option, Raman spectra are acquired from precisely along a surface or at a set, user-defined distance from a surface. As the sensor actively monitors and maintains a set distance between the objective and sample surface, its closed-loop operation can compensate for any variations during measurements with long integration times. This keeps the measurement area in constant focus and produces sharp confocal Raman images with sub-micrometer resolution. Topographic Raman imaging also allows the distribution of chemical components within the sample to be visualized in three dimensions.


Figure 1: (a) Topographic Raman image of a pharmaceutical pain tablet containing acetylsalicylic acid, isobutylphenylpropionic acid, caffeine, and auxiliary substances shows the distribution of the components along the tablet's curved surface. (b) Corresponding spectra of the tablet's ingredients.

Here we demonstrate the technique's capabilities by carrying out Raman imaging of the surface of a curved pharmaceutical tablet (Figure 1) and of cellulose fibers in paper (Figure 2).


Figure 2: Confocal Raman image of cellulose fibers in paper. Fibers of different orientation are marked with green and blue.

Investigations on pharmaceutical tablet ingredients, geological samples, composite emulsions, complex semiconductor structures, organic material, and many other applications can benefit from the ease of use, accelerated workflow, and methodological advantages provided by the new TrueSurface™.