News|Articles|March 21, 2024

Carbon Quantum Dots Tested for Hypochlorite Detection and Cell Imaging

Author(s)Aaron Acevedo

In a study led by scientists from Northwest University in Xi’an, China, carbon quantum dots were tested on how well they can detect hypochlorite and aid in cellular imaging.

In a study led by scientists from Northwest University in Xi’an, China, carbon quantum dots were tested on how well they can detect hypochlorite and aid in cellular imaging (1). The findings were published in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy.

Hypochlorite (ClO-) is seen as an important reactive oxygen species that helps in different physiological and pathological processes within organisms. It can be used as a disinfectant and preservative for environmental sanitization and food preservation. Unfortunately, excessive ClO- can disturb redox balances and cause severe threats to human health, like respiratory irritation, lung damage, atherosclerosis, and cancer. This has led to a need for accurate and sensitive ClO- concentration monitoring techniques, especially so regarding the fields of life sciences, food, and the environment.

There are various methods for analyzing ClO-, including high performance liquid chromatography (HPLC), surface-enhanced Raman scattering, colorimetry, and fluorescence methods. Of the above methods, fluorescence and colorimetry have shown high accessibility, easy preparation, non-invasive nature, high sensitivity, and good comparability for bio-samples. This led the scientists to choose dual-mode methods for potential and application prospects for analysis and detection.

As part of the experiment, bright green, fluorescent carbon quantum dots (G-CQDs) were synthesized using a one-step hydrothermal method, which has citric acid and acriflavine precursors. Carbon dots (CDs) are crystalline and “zero-dimensional” carbon nanomaterials that have gained widespread attention; green CDs are specifically synthesized from renewable biomass, such as plants and other organic biomaterials (2).

Read More: Green Carbon Dots: Synthesis, Characterization, Properties and Biomedical Applications

Multiple characterization procedures were used throughout this experiment. The morphology and size of G-CQDs were measured by transmission electron microscopy (TEM), while Fourier transform infrared spectroscopy (FTIR), X-ray photoelectron spectroscopy (XPS), and zeta potential characterization assisted in helping the G-CQDs illustrate a significant amount of uniformly dispersed –NH2 and –OH on the surface. The fluorescence and colorimetric analysis helped in displaying a wide linear range and a low detection limit response to ClO-.

After the main part of the experiment, G-CQDs were applied for visualizing and quantitively detecting ClO- in drinking water samples, with the results showing a satisfactory recovery rate. Additionally, the dots showed good water solubility, optical stability, and optimal biocompatibility, all of which foreshadow a promising analysis approach in cell imaging and ClO- detection in living cells. This experiment highlighted the benefits and potential of G-CQDs, showing their capabilities in ClO--associated disease prevention and early clinical diagnosis.

References

(1) Chen, H.; Li, D.; Zheng, Y.; Wang, K.; et al. Construction of Optical Dual-Mode Sensing Platform Based on Green Emissive Carbon Quantum Dots for Effective Detection of ClO and Cellular Imaging. Spectrochim. Acta Part A: Mol. Biomol. Spectrosc. 2024, 309, 123733. DOI: https://doi.org/10.1016/j.saa.2023.123733

(2) Jing, H. H.; Bardakci, F.; Akgöl, S.; Kusat, K.; et al. Green Carbon Dots: Synthesis, Characterization, Properties and Biomedical Applications. J. Funct. Biomater. 2023, 14 (1), 27. DOI: https://doi.org/10.3390/jfb14010027


Related to this article

Curated 2026 Evergreen Content from Spectroscopy. ©  Chanakarn -chronicles-stock.adobe.com
Spectroscopy's editors gather 143 evergreen articles from 2026, including tutorials, terminology guides, technique reviews, application surveys, peer-reviewed research and the magazine's long-running columns, and organize them by subject so readers can build lasting knowledge one topic at a time.
Spectroscopy Top 10 DOI Articles of the Month (October 2026)
The following articles are the most accessed digital object identifier (DOI) manuscripts for Spectroscopy and LCGC International during the month of October 2026. Nine articles are individually ranked here by DOI page views; the seventh-highest entry (99 views) was recorded against the bare LCGC North America journal-level DOI rather than an individual article and is therefore not attributable to a single manuscript.