A Comparison of Raman Analysis of Carbon Nanotubes

A new Raman spectrometer system, innoRamâ„¢, has been developed to provide research-grade performance in either a lab or a mobile environment. The Raman analysis of carbon nanotubes using innoRam in comparison with a Raman spectrometer using a conventional front illuminated CCD demonstrates distinctive improvements for innoRam in both sensitivity and signal-to-noise ratio (SNR).

Dawn Yang, B&W Tek, Inc.

A new Raman spectrometer system, innoRam™, has been developed to provide research-grade performance in either a lab or a mobile environment. The Raman analysis of carbon nanotubes using innoRam in comparison with a Raman spectrometer using a conventional front illuminated CCD demonstrates distinctive improvements for innoRam in both sensitivity and signal-to-noise ratio (SNR).

B&W Tek's newly developed Raman system, innoRam™, is a research-grade Raman spectrometer with high sensitivity and application versatility. The innoRam's back-thinned 2D vertically binned CCD detector with TE-cooling to –20 °C ensures research-grade performance. The application discussed in this paper is a comparison of Raman analysis of carbon nanotubes between innoRam and a Raman spectrometer with front-illuminated linear CCD detector with TE-cooling to 14 °C.

Compared with a conventional front-illuminated CCD with quantum efficiency around 50%, the back-thinned or back-illuminated CCD quantum efficiency can reach up to 90%. The lower QE of a front-illuminated CCD is due to the incident photons being largely reflected and absorbed by gate structures (Poly-Si, BPSG, gate oxide) while traveling through the front side of the CCD. A back-thinned CCD minimizes these losses by etching the Si substrate (to limit the absorption) and illuminating the CCD from behind. This greatly increases its quantum efficiency by reducing the photon loss. Due to the low photon efficiency of the Raman phenomenon (10–8), detectors used in Raman spectrometry must have readout noise and dark noise that is very low to identify the Raman signal from the sample. TE-cooling of the CCD device effectively reduces the dark noise: the dark noise halves for each 7 °C decrease in device temperature. The deep TE-cooled detector allows long integration time (up to 16 minutes for innoRam), which greatly increases the detection limit. 2D binning, which is to combine two or more vertical rows of the CCD array, is another technique to improve signal-to-noise ratio. The characteristics of the detector make innoRam ideal for low-light level applications.

Experiment and Results

The Raman spectrum of carbon nanotubes was collected using B&W Tek's innoRam Raman spectrometer system (Figure 1a) with 785 nm laser excitation. The Raman spectrum of carbon nanotubes measured from innoRam is shown in Figure 1 (b). The Raman spectrum of the same carbon nanotubes using a Raman spectrometer with a front-illuminated linear CCD TE-cooled to 14 °C is shown in Figure 1 (c). In order to have a direct comparison, the same laser power (25 mW) and integration time (10 sec) were used for both Raman measurements. The comparison of Figure 1 (b) and (c) shows distinctive improvement of SNR and increase of intensity in the spectrum from the innoRam.

Figure 1

Conclusions

B&W Tek's innoRam Raman spectrometer system, featuring a back-thinned 2D vertically binned CCD detector with TE-cooling to –20 °C, provides research-grade performance with high sensitivity and SNR, which is clearly demonstrated by the comparison of Raman analysis of carbon nanotubes between innoRam and a Raman system using a conventional front-illuminated linear CCD with TE-cooling to 14 °C.

B&W Tek, Inc.

19 Shea Way, Newark, DE 19713

Tel. (302) 368-7824, Fax: (302) 368-7830

Website: www.bwtek.com, Email: info@bwtek.com


Related to this article

A robotic arm in an automated agricultural setting, carefully processing a conveyer belt with tomatoes and leafy greens for food production. | Image Credit: © Donnangelo - stock.adobe.com
Croatian researchers outline how optical emission spectroscopy (OES) can track reactive species and plasma parameters in real time, giving processors a path to move cold plasma treatments from the laboratory to production lines.
Spectroscopy Top 10 DOI Articles of the Month (October 2026)
The following articles are the most accessed digital object identifier (DOI) manuscripts for Spectroscopy and LCGC International during the month of October 2026. Nine articles are individually ranked here by DOI page views; the seventh-highest entry (99 views) was recorded against the bare LCGC North America journal-level DOI rather than an individual article and is therefore not attributable to a single manuscript.
Mapping Molecular Mobility Pixel by Pixel
Garth Simpson of Purdue University explains how patterned photobleaching and spatial Fourier transforms can turn a single-point measurement into a diffusion coefficient at every pixel in the field of view.
Optical and Electronic Instrument Components,  ©  ridwan -chronicles-stock.adobe.com
The updated and expanded 2026 edition of Spectroscopy's Instrument Components Terminology Guide defines the sources, detectors, optical and dispersive elements, sampling hardware, physical constants, and unit conversions used across UV-vis, NIR, IR, Raman, X-ray, and atomic spectroscopic instrumentation, with new terms reflecting component developments reported between 2022 and 2026.