Dangerous Toys: Rigid Testing Routines Required to Assure Our Children's Safety

Toys conjure up the images of happy little children playing safely with their dolls and model cars but lately, those images have become tarnished by some well publicized recalls of toys made in China. With Chinese made toys accounting for well over 80% of the American market, and dolls even higher, it is understandable that there is general loss of confidence in the toy industry.

The European Union (EU) has a directive RoHS (restriction of hazardous substances) that places strict limits on the amount of heavy metals such as lead, cadmium and mercury that are allowed in consumer goods. Since it applies to all products entering Europe, it should affect all countries that export toys. In theory, this should protect consumers throughout the world but manufacturers do cut corners and it is impossible for the individual countries to verify that every batch of every toy that enters that market is in compliance. Therefore, it is in the best interests of everyone, including the manufacturers, to prove through a vigorous internal quality control program, that their products are safe.

Sample preparation steps

In order to accurately detect trace amounts of such heavy metals, any testing method must produce reliable, reproducible results and be relatively simple and quick to perform. The method must also be able to detect trace amounts hidden inside the item as well as on the surface since this is the only certain way of knowing whether or not the item is safe for the consumer.

Figure 1: Cutting Mill SM 2000 for initial size reduction of a plastic doll pieces to 3–4 mm.

In order for testing to be carried out, the toy or item has to be turned into a sample that can be presented to the analyzer that will be used This requires size reduction and homogenization to ensure that the final sample represents as closely as possible the exact composition of the original item including any accessory parts.

Primary Size Reduction

Initially, the toy should be dismantled into its various components and separated into different analysis groups (e.g. plastics of different colors, electronic parts, rubber etc.). In the next step, these items should be processed in a mill such as the Heavy Duty Cutting mill SM 2000 to produce a size of 3–4 mm. This mill, with its offset hard-metal cutting bars, is ideally suited for this preliminary size reduction of such heterogeneous materials.

Sampling, Dividing, and Fine Grinding

In order to maintain the representative nature or the material, this ground sample should be divided into representative sub-samples using a spinning riffler such as the Retsch PT 100 or PK 1000. The sub-sample(s) produced in this step are further homogenized in the Ultra-Centrifugal Mill ZM 200 which achieves a final size below 200 μm in a very short time and in addition, is very gentle on the material. It is recommended that liquid nitrogen or dry ice be used to improve the breaking properties of the material during this step; at the same time this will help preserve any volatile substances which might otherwise be affected by the frictional heat generated during grinding. Heavy-metal-free grinding tools are available for both mills so that subsequent analyses are not influenced by trace amounts of material from the grinding tools.

Depending on the type of toy, it may also be necessary to analyze fibrous materials such as clothing or hair. These materials can be best processed in the Mixer Mill Mill MM 301 or MM 400 which homogenizes sample volumes up to 40 mL in only 1–2 min. The screw-capped grinding jars, complete with sample and grinding balls, are cooled in liquid nitrogen before being clamped in the mill. This external cooling eliminates the need for any additional cooling during grinding and ensures that the whole process is carried out efficiently and quickly.

Analysis

The complete procedure of preparing a heterogeneous toy sample for subsequent analysis as described above takes about 30 minutes including additional preparation steps such as pelletizing. After that, hazardous substances can be detected by analyzing the dry sample with X-ray fluorescence (heavy metals) or NIR (plasticizers) or, after wet extraction, with AAS or ICP-MS (heavy metals).

All laboratory mills mentioned in this article can be equipped with grinding tools for heavy-metal-free sample preparation. This ensures that the results of the subsequent analyses are not influenced by undesired sample contamination from trace elements in the grinding tools.

Retsch, Inc.

74 Walker Lane, Newtown, PA 18940

Tel. (866) 473-8724

info@retsch-us.com, www.retsch-us.com


Related to this article

Monitoring Sugar Consumption and Ethanol Production During Yeast Fermentation Using a Raman Plate Reader and Multivariate Analysis
This column shows that a Raman plate reader paired with partial least squares regression can simultaneously quantify glucose, fructose, sucrose, and ethanol in yeast fermentation samples, using turbidity-matched calibration standards to correct for yeast-induced turbidity, and offers a rapid, label-free, high-throughput method for tracking sugar consumption and ethanol production in strain screening, media optimization, and process development.
Highly Substituted Benzene Rings—The Rest of the Story II: Spectra
This column, the second installment on highly substituted benzene rings, shows that tri- and tetra-substituted substitution patterns can be distinguished by whether the ring bending peak is present and by the position of the in-phase aryl C-H wagging peak, which shifts according to how many adjacent hydrogens the ring carries.
Healthcare administrator reviewing an insurance policy schedule with a stethoscope on a clipboard, health insurance coverage, medical underwriting, prior authorization, and patient claims processing. | Image Credit: Joi_studio - stock.adobe.com
In a SciX interview, Marc Porter covered a lot of ground, from a student-driven pivot into immunoassays to a baseball analogy for Stokes and anti-Stokes scattering, and shares the open questions he is still chasing.