|Articles|September 3, 2017

Application Notebook

  • Application Notebook-09-01-2017
  • Volume 32
  • Issue 9

Diamond Anti-Reflection Coating

Diamond is an important material choice for sampling optical elements in Fourier transform-infrared (FT-IR) spectroscopy. The multi-phonon absorption in the mid-infrared, although temperature dependent, is weak for thin optical elements and can be referenced to an empty cell background. However, the cost of diamond optics requires the sampling area to be very small. As a result, the signal-to-noise ratio (SNR) advantages of the FT-IR systems are frequently stretched to the limit and more energy throughput is usually quite helpful.

Frequently, the sampling technique of choice is attenuated total reflection (ATR) for its benefits of ease of analysis. ATR elements can be manufactured from most optical materials of relatively high refractive index. Ge, Si, ZnSe, ZnS, KRS-5, and diamond are often used for this application. For most of these materials, a broad band anti-reflection (BBAR) coating can be applied to both surfaces of a window or the entrance and exit facets of an ATR element and can significantly increase the energy throughput of the sampling accessory or system.

Since diamond and ZnSe have similar refractive indexes a similar BBAR can be used on diamond once the binding layers of the coating are appropriately modified.

Spectral Systems has developed its Diamond XP-BBAR(tm) coating with spectral performance as shown in Figure 1.

It is seen in Figure 1 that the energy and thus the SNR is about 30% better through most of the analysis region of a typical FT-IR instrument.

Since there are no suitable coating materials for the very long wavelength portion of the spectrum the coated element is not as good, but still usable, below 600 cm-1. If a liquid nitrogen cooled MCT detector is used, this portion of the spectrum is usually not recorded by the spectrometer.

Spectral Systems
35 Corporate Park Drive, Hopewell Junction, NY 12533
tel. (845) 896-2200
Website: www.spectral-systems.com


Related to this article

Highlights from What’s Nu October 2026
In this Q&A, we recap the October edition of “What’s Nu,” which covered topics such as how novel spectroscopic and analytical methods are transforming environmental monitoring, medical treatment, and accessibility in scientific research.
Education distance learning, e-learning, and online learning are all types of personal development. | Image Credit: © ipuwadol - stock.adobe.com
In this segment of our SciX interview with Kevin Wilkinson, a professor of environmental chemistry at the Université de Montréal, discusses extending lead isotope work to greater distances and explains why graduate students need adaptability, critical judgment, and coding skills more than expertise in any single instrument.
Atoms Don't Lie–The Remaking of Atomic Spectroscopy, © Hallie -chronicles-stock.adobe.com
Atomic spectroscopy has quietly gone from counting elements in bulk to counting single nanoparticles, imaging tissue at the micrometer scale, and reading Martian rocks from several meters away. The instruments got smaller, the software got smarter, and the questions they can now answer got a lot more interesting.