News|Articles|April 9, 2024

Diseased Silkworms Screened Using Portable NIR Spectroscopy

Author(s)Aaron Acevedo

Scientists from the Jiangsu University of Science and Technology in Zhenjiang, China recently tested different analysis methods of using portable near-infrared (NIR) spectroscopy to detect Bombyx mori nuclear polyhedrosis virus within silkworms. Their findings were published in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy (1).

Raw silk production accounts for 82% of the world’s sericulture production. This process occurs when silkworms spin themselves into a cocoon, with the ultra-soft fibers being harvested from the cocoon in their raw state by being boiled in hot water and stirred until the cocoons unravel (2). However, this process has several problems to it, one of which being that silkworms can be easily infected by viruses. The most common and harmful virus that affects silkworms is Bombyx mori nuclear polyhedrosis virus (BmNPV). For early BmNPV diagnosis, conventional methods rely on human senses, which are highly sensitive to subjective influence that can lead to low accuracy. Alternate methods have been created for this purpose, such as the anti-viral antibody-based ELISA and nucleic acid probes; however, while highly sensitive, they can be high-cost, time-consuming, and labor-intensive. As such, fast, accurate, and effective early diagnosis methods are still needed.

For this study, a portable near-infrared (NIR) spectroscopy system was used to collect the spectra of normal silkworms and the infected silkworms induced by BmNPV administration. Unlike traditional NIR spectrometers, portable NIR spectrometers can perform on-site analysis without needing to transport samples back to a laboratory, which improves work efficiency and saves both time and money.

Various spectral methods were applied for the classification analysis; principal component analysis (PCA), linear discriminant analysis (LDA), and partial least squares discriminant analysis (PLSDA) were used. However, PCA and LDA were unable to achieve accurate classification results.

For the PLSDA calibration, after spectra pretreatment using a standard normal variate (SNV) transformation combined with second derivative, the technique yielded a highly accurate identification performance. The PLSDA approach resulted in low classification errors of 0.023, 0.033, and 0.030 for the calibration set, cross-validation set, and test set, respectively. To summarize these results, misclassification occurred 2.3% of the time for the calibration set; 3.3% of the time for the cross-validation set; and 3.0% of the time for the test set. All these factors were captured with higher sensitivity and specificity. These findings allowed scientists to identify BmNPV-infected silkworms using portable NIR spectroscopy; though there is more research to be done in this regard, this method has the potential to effectively reduce losses for the sericulture industry.

References

(1) Liu, Y.; Deng, S.; Li, Y.; Zhang, Y.; et al. Fast Identification of the BmNPV Infected Silkworms by Portable NIR Spectroscopy and Chemometrics. Spectrochim. Acta Part A: Mol. Biomol. Spectrosc. 2024, 314, 124158. DOI: https://doi.org/10.1016/j.saa.2024.124158

(2) Jackson, F. How Is Silk Made, And Is It Vegan? Allplants Ltd 2024. https://allplants.com/blog/lifestyle/how-is-silk-made-and-is-it-vegan (accessed 2024-4-8).


Related to this article

Curated 2026 Evergreen Content from Spectroscopy. ©  Chanakarn -chronicles-stock.adobe.com
Spectroscopy's editors gather 143 evergreen articles from 2026, including tutorials, terminology guides, technique reviews, application surveys, peer-reviewed research and the magazine's long-running columns, and organize them by subject so readers can build lasting knowledge one topic at a time.
Atoms Don't Lie–The Remaking of Atomic Spectroscopy, © Hallie -chronicles-stock.adobe.com
Atomic spectroscopy has quietly gone from counting elements in bulk to counting single nanoparticles, imaging tissue at the micrometer scale, and reading Martian rocks from several meters away. The instruments got smaller, the software got smarter, and the questions they can now answer got a lot more interesting.
Spectral Frontiers: Seeing the Unseeable Microspectroscopy
Microspectroscopy, the marriage of spectroscopic chemical identification with microscopic spatial resolution, has advanced from Perkin-Elmer's first commercial infrared microspectrometer in 1953 to today's nanoscale AFM-IR probes, synchrotron-brightness infrared beamlines, and compact hyperspectral tissue imaging devices being developed for AI-assisted cancer detection.