A recent study explored using surface-enhanced Raman spectroscopy (SERS) to detect β-agonists.
Banned substances in sports are strictly enforced for the sake of keeping athletic competitions as fair as possible. However, for policies prohibiting specific substances to be effective, it requires the use of analytical techniques that can detect potential illicit substances in athletes’ bodies. In a recent study published in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, researchers from Xihua University in Chengdu, China, led by Chuanfeng Wang, Yahui Zhang, and Xiaojun Luo, explored this topic by developing and testing a novel method for detecting β-agonists using surface-enhanced Raman spectroscopy (SERS) (1). This approach leverages gold polyhedral substrates synthesized through a seed-mediated technique, enabling highly sensitive and rapid detection of β-agonist compounds (1).
Doping for athletes. Golds, silver and bronze medal and doping syringe and pills with capsules on a gray background | Image Credit: © adragan - stock.adobe.com
β-Agonists, sometimes written as beta-agonists, are one type of banned substances that are included on the World Anti-Doping Agency's (WADA) list of prohibited substances (1). β-Agonists are bioactive catecholamine compounds naturally produced in the adrenal medulla glands of animals (1). They serve as medications to help treat specific lung conditions, such as asthma (2). They function by binding to beta-receptors in the body, and this causes certain functions to perform in the body, which include relaxing the muscles in several organs, such as the lungs (2).
However, the use of β-Agonists can result in several potentially severe side effects. Patients may experience hypertension, shakiness, and an irregular heart rate (2). Because of these deleterious side effects, using β-Agonists is disincentivized and discouraged (1).
In this study, the researchers used gold polyhedral substrates to improve the SERS signals associated with β-agonist compounds. Using SERS allowed the researchers to obtain low detection limits: 9.33 × 10−7 g/mL for salbutamol, 6.28 × 10−7 g/mL for clenbuterol, and 6.19 × 10−7 g/mL for higenamine (1). These results demonstrate the potential of SERS as a powerful tool for detecting trace amounts of β-agonists in biological samples.
To produce the gold polyhedral nanoparticles, the research team used a seed-mediated synthesis technique. Gold polyhedral nanoparticles are characterized by their shape, and their multiple corners helps amplify SERS signals (1). The enhancement factor for this system, evaluated using 4-aminothiophenol (4-ATP) as a beacon molecule, was determined to be 1.92 × 10⁵ (1).
Once the gold polyhedral nanoparticles were produced, the team conducted a series of experiments using urine samples to test the effectiveness of their method. The results were encouraging. The researchers observed great enhancement effects and a strong linear relationship between signal intensity and β-agonist concentration across a range of 10−3 to 10−6 g/mL (1). This approach allows for direct detection without the need for complex pretreatment processes, significantly simplifying the detection procedure.
As a result, this study can serve as another way to improve anti-doping protocols in sports. The researchers demonstrated that their method’s high sensitivity and rapid detection capabilities can effectively identify banned substances, ensuring fair and clean competition (1). The ability to quantify β-agonist concentrations with precision further enhances the integrity of anti-doping efforts (1).
By optimizing the gold polyhedral substrate and expanding its use to other banned substances, the team hopes to develop a robust and reliable tool for safeguarding the integrity of sports competitions (1). Their efforts will focus on translating these findings into actionable solutions that can be seamlessly integrated into existing anti-doping protocols (1).
Using SERS with gold polyhedral substrates represents a significant advancement in the field of molecular spectroscopy. This method not only provides a fast, simple, and effective means of detecting β-agonists but also paves the way for more comprehensive and reliable anti-doping strategies (1).
AI Boosts SERS for Next Generation Biomedical Breakthroughs
July 2nd 2025Researchers from Shanghai Jiao Tong University are harnessing artificial intelligence to elevate surface-enhanced Raman spectroscopy (SERS) for highly sensitive, multiplexed biomedical analysis, enabling faster diagnostics, imaging, and personalized treatments.
Tip-enhanced Raman Scattering using a Chemically-modified Tip
Published: June 9th 2025 | Updated: June 17th 2025In this tutorial article, Yukihiro Ozaki explores the recent advancements and broadening applications of tip-enhanced Raman scattering (TERS), a cutting-edge technique that integrates scanning probe microscopy (SPM) with surface-enhanced Raman scattering (SERS). TERS enables highly localized chemical analysis at the nano- to subnano-scale, achieving spatial resolution well beyond the diffraction limit of light. Ozaki highlights the versatility of TERS in various experimental environments—ranging from ambient air to ultrahigh vacuum and electrochemical systems—and its powerful utility in fields such as single-molecule detection, biomolecular mechanism studies, nanomaterial characterization, and high-resolution imaging.
Machine Learning Accelerates Clinical Progress of SERS Technology
May 22nd 2025A new review in TrAC Trends in Analytical Chemistry by Alfred Chin Yen Tay and Liang Wang highlights how machine learning (ML) is transforming surface-enhanced Raman spectroscopy (SERS) into a powerful, clinically viable tool for rapid and accurate medical diagnostics.
New SERS Platform Enhances Real-Time Detection of Cardiovascular Drugs in Blood
May 13th 2025Researchers at Harbin Medical University recently developed a SERS-based diagnostic platform that uses DNA-driven “molecular hooks” and AI analysis to enable real-time detection of cardiovascular drugs in blood while eliminating interference from larger biomolecules.