A group of scientists from China investigated the potassium isotopic composition of different plant reference materials using multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS). Their work was published in Spectrochimica Acta Part B: Atomic Spectroscopy (1).
Potassium. Kalium. Alkali metals. Chemical Element of Mendeleev's Periodic Table. Potassium in square cube creative concept. | Image Credit: © Aleksander - stock.adobe.com
In this study, the potassium isotopic composition (δ41K) of five certified plant reference materials (BCR 679, GSV-2, GSB-2a, GSB-3 and GSB-6a) with varying potassium concentrations was assessed using MC-ICP-MS. This system employed a reduced radio frequency (RF) forward power and low-resolution mode without a collision cell. The δ41K values of the plant reference materials (BCR 679, GSV-2, GSB-2a, GSB-3 and GSB-6a) were recorded as −2.44 ± 0.03‰, −0.37 ± 0.04‰, −0.37 ± 0.05‰, −1.27 ± 0.04‰ and − 0.62 ± 0.01‰, respectively. According to the study, the δ41K values of plants being presented in this study allowed a methodology for pre-treatment and determination of δ41K in plants to be established. δ41K is now believed to have potential as a notable tracer in ecosystems’ “soil-plant systems”, though further research is needed in this regard (1).
Potassium (K) is crucial for living cells to function. It specifically holds significant importance as a nutrient for plants, comprising up to 10% of plant biomass on a dry weight basis. However, despite being abundant in soil, there is a lack of K availability for plants, which places great importance on understanding the K cycle in soil-plant systems. One recent avenue of analysis is developing high-precision stable K isotopic composition analysis, which allows for the study of both K concentration and isotopic fractionation (1).
Three potassium isotopes exist in nature, 39K, 40K, 41K, with 39K and 40K being the most stable K isotopes. Using MC-ICP-MS, scientists have been able to improve isotope ratio measurements. This enables precision K isotopic analysis to be routinely achieved with precision better than 0.06%. High-precision K isotopic analysis can be achieved using two different approaches. The first involves using high-resolution mode to segregate Ar hydrides and K after the suppression of Ar through the reduction of radio frequency (RF) forward power using cold plasma. The second approach uses the “collision gas” strategy to eliminate Ar-based ionic species.
(1) He, M-Y.; Ren, T. X.; Jin, Z. D.; Deng, L.; Liu, H. J.; Cheng, Y. Y.; Li, Z. Y.; Liu, X. X.; Yang, Y.; Chang, H. Precise Analysis of Potassium Isotopic Composition in Plant Materials By Multi-Collector Inductively Coupled Plasma Mass Spectrometry. Spectrochim. Acta Part B At. Spectrosc. 2023, 209, 106781. DOI: https://doi.org/10.1016/j.sab.2023.106781
Evaluating Microplastic Detection with Fluorescence Microscopy and Raman Spectroscopy
July 2nd 2025A recent study presented a dual-method approach combining confocal micro-Raman spectroscopy and Nile Red-assisted fluorescence microscopy to enhance the accuracy and throughput of microplastics detection in environmental samples.
Mediterranean Origins of Red Coral Artifacts in Xinjiang Reveal Ancient Silk Road Trade Links
June 26th 2025A new study published in Minerals reveals that red coral artifacts unearthed in Xinjiang’s Shengjindian cemetery originated from the western Mediterranean, highlighting early Silk Road trade and long-distance cultural exchange during the Han Dynasty.
A Life Measured in Peaks: Honoring Alan George Marshall (1944–2025)
June 18th 2025A pioneer of FT-ICR Mass Spectrometry, Alan G. Marshall (1944–2025), is best known for co-inventing Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS), a transformative technique that enabled ultrahigh-resolution analysis of complex mixtures. Over a career spanning more than five decades at institutions like the University of British Columbia, The Ohio State University, and Florida State University, he published over 650 peer-reviewed papers and mentored more than 150 scientists. Marshall’s work profoundly impacted fields ranging from astrobiology to petroleomics and earned him numerous prestigious awards and fellowships. Revered for his intellect, mentorship, and dedication to science, he leaves behind a legacy that continues to shape modern mass spectrometry.
New Machine Learning Model Distinguishes Recycled PET with 10% Accuracy Threshold
June 9th 2025Researchers from Jinan University and Guangzhou Customs Technology Center have developed a cost-effective UV-vis spectroscopy and machine learning method to accurately identify recycled PET content as low as 10%, advancing sustainable packaging and circular economy efforts.