SPEC PerkinElmer 11.10
News|Articles|April 4, 2024

Reflectance Spectroscopy Tested for Identifying Fungi Species

Author(s)Aaron Acevedo

A recent study led by Henryk Ratajkiewicz of the Poznan University of Life Sciences in Poznań, Poland tested how multidimensional discriminant analysis and reflectance spectroscopy can help identify species within fungi strains. The team’s research was published in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy (1).

Approximately 120,000 fungi species have been discovered, putting the total number of fungi at more than 1.5 million. To properly identify species, scientists must find measurable features and traits that distinguish one species from another. Within the past decade, techniques used for isolating and identifying entomopathogenic fungi have evolved. Rather than focusing on morphological characterization, now scientists use more molecular techniques, which have become more widely used for genotypic identification (1). These techniques usually deploy polymerase chain reaction-based amplification of different DNA or RNA fragments. Some of these techniques can also be used in diversity studies, improving basic knowledge about entomopathogenic fungi.

Read More: Quantitative Mapping of Mercury and Selenium in Mushroom Fruit Bodies with Laser Ablation–Inductively Coupled Plasma-Mass Spectrometry

For this study, the scientists investigated whether intraspecific differences can be detected in two closely related entomopathogenic species, Cordyceps farinosa and Cordyceps fumosorosea, using ultraviolet A to shortwave infrared (UVA-SWIR) reflectance spectra. Phylogenetic analysis of all the strains used in the study revealed a high degree of uniformity among the populations of both species. The team also determined the characteristics that resulted from either species variation or culture aging. Fungi were cultured on PDA medium, with the scientists then measuring the reflectance of mycelia in the 350–2500 nm range after 10 and 17 days (1). The measurements were subsequently subjected to quadratic discriminant analysis (QDA) to identify the minimum number of bands containing meaningful information.

Following these procedures, the scientists found that when they knew the age of a fungal culture, species represented by a group of varying strains could be distinguished with only 3–4 wavelengths, compared to needing 7–8 wavelengths when not knowing the age of a culture. At least 6–8 bands were needed to distinguish cultures of a known species among different age groups; however, distinguishing all strains within a species proved more demanding. For C. fumosorosea, at least 10 bands were required, and for C. farinose, 21 bands. These findings show that using point reflectance spectroscopy for fungal differentiation, when intraspecific and age variations are considered, can provide reliable results.

Reference

(1) Jasiewicz, J.; Pierkarczyk, J.; Stępién, Ł.; Tkaczuk, C.; et al. Multidimensional Discriminant Analysis of Species, Strains and Culture Age of Closely Related Entomopathogenic Fungi Using Reflectance Spectroscopy. Spectrochim. Acta Part A: Mol. Biomol. Spectrosc. 2024, 313, 124135. DOI: 10.1016/j.saa.2024.124135


Related to this article

Spectral Frontiers: Seeing the Unseeable Microspectroscopy
Microspectroscopy, the marriage of spectroscopic chemical identification with microscopic spatial resolution, has advanced from Perkin-Elmer's first commercial infrared microspectrometer in 1953 to today's nanoscale AFM-IR probes, synchrotron-brightness infrared beamlines, and compact hyperspectral tissue imaging devices being developed for AI-assisted cancer detection.
Spectroscopy Top 10 DOI Articles of the Month (September 2026)
The following articles are the most accessed digital object identifier (DOI) manuscripts for Spectroscopy and LCGC International during the month of September 2026. Nine articles are individually ranked here by DOI page views; the third-highest entry (186 views) was recorded against the bare journal-level DOI rather than an individual article and is therefore not attributable to a single manuscript.
Highly Substituted Benzene Rings—The Rest of the Story II: Spectra
This column, the second installment on highly substituted benzene rings, shows that tri- and tetra-substituted substitution patterns can be distinguished by whether the ring bending peak is present and by the position of the in-phase aryl C-H wagging peak, which shifts according to how many adjacent hydrogens the ring carries.
Atoms Don't Lie–The Remaking of Atomic Spectroscopy, © Hallie -chronicles-stock.adobe.com
Atomic spectroscopy has quietly gone from counting elements in bulk to counting single nanoparticles, imaging tissue at the micrometer scale, and reading Martian rocks from several meters away. The instruments got smaller, the software got smarter, and the questions they can now answer got a lot more interesting.
Tutorial Tuesday: When to Use Infrared Spectroscopy
In this “Tutorial Tuesday” clip, Peter Larkin, who is a Manager of Spectroscopy, Thermal Analysis, and Chromatography at Syensqo, highlights how people use the method or technique that they are comfortable with, even if it’s not the best one to use.