A recent study examined how Raman spectroscopy, when combined with machine learning (ML), can detect and analyze fertilizer nutrients.
Farmers rely on fertilizer to help grow their crops and produce the greatest harvest yield. As a result, they have an interest in knowing the nutrient content in the fertilizer that they use, so they can ensure they are using the most optimal fertilizer for their crops.
A recent study led by researchers from Kunming University of Science and Technology recently explored this topic. In a study published in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, the researchers proposed a new efficient method to detect and analyze fertilizer nutrients using Raman spectroscopy combined with machine learning (ML) (1). Their study demonstrates that their method could potentially address several key problems in traditional fertilizer analysis, including the difficulty in quantifying multiple components and risks of cross-contamination (1).
Feeding lawn with granular fertilizer for perfect green grass | Image Credit: © ronstik - stock.adobe.com
In essence, fertilizer is plant nutrition (2). Without fertilizer, plants cannot grow to their full potential, which is why farmers rely on them (2). However, bad fertilizer, or overusing it, can be counterproductive. Using too much fertilizer can ultimately kill the plant or crop (3). Therefore, the rapid and accurate detection of fertilizer nutrient information is critical to modern agricultural practices. Traditional techniques, while effective, are often time-consuming and limited in their ability to analyze multiple components simultaneously (1). The research team attempted to resolve these challenges by using Raman spectroscopy and integrate it with ML algorithms (1).
Their study focused on five commonly used fertilizers: potassium sulfate (K₂SO₄); urea (CO(NH₂)₂); monopotassium phosphate (KH₂PO₄); potassium nitrate (KNO₃); and a composite fertilizer (N:P:K 15-15-15). Using five spectral preprocessing methods, including Savitzky-Golay (S-G) smoothing, standard normal variate (SNV), multiplicative scatter correction (MSC), detrending (DT), and normalization (NOR), these preprocessing methods were designed to improve the quality of the Raman spectra (1). These preprocessing techniques were crucial in improving the accuracy and robustness of the calibration models.
The researchers then tested three classification algorithms to see how effective they were at identifying the five fertilizer types. These classification algorithms were random forest (RF), particle swarm optimization support vector machine (PSO-SVM), and radial basis function neural network (RBFNN). Out of these algorithms, RF achieved the best classification accuracy at 100%, demonstrating its potential utility in fertilizer identification (1).
For the quantitative analysis part of the study, the researchers compared partial least squares regression (PLSR), extreme learning machine (ELM), and least squares support vector machine (LSSVM). Out of these, PLSR emerged as the top-performing algorithm, with prediction coefficients of determination (Rp2) ranging from 0.9843 to 0.9990 and root mean square errors (RMSE) between 0.0486 and 0.1691, indicating great accuracy in predicting fertilizer concentrations (1).
An interesting wrinkle to this study was the researchers’ examining different water types and how they impact the detection of fertilizer nutrients. Although the water type, whether it was deionized water, well water, or industrial transition water, did not significantly affect the qualitative identification of fertilizer components, it had a noticeable influence on the quantification of nutrient concentrations (1). This finding showcases the importance of accounting for water composition in real-world applications of Raman spectroscopy (1).
As the researchers showed in their study, integrating Raman spectroscopy with ML can help farmers and researchers rapidly, non-destructively, and accurately detect multicomponent fertilizer solutions (1). By optimizing spectral preprocessing and leveraging advanced machine learning algorithms, the researchers have developed a robust framework that ensures high accuracy and reproducibility in both qualitative and quantitative analyses (1).
Modern agricultural practices are concentrated on reducing waste and enhancing crop yield. Using Raman spectroscopy has become one way to accomplish both these objectives. This study is further evidence that further exploration into how Raman spectroscopy can be used to detect other agricultural inputs and contaminants (1).
Having the right fertilizer and dispensing it in the proper amount is key to ensure agricultural efficiency and success. Farmers are constantly faced with the important decision of selecting the right fertilizer. Choosing the right one takes more than just knowing the right balance of nitrogen, phosphorus, and potassium content (3). Thanks to Raman spectroscopy and ML algorithms, it has become easier for farmers to select the right fertilizer for their plants.
Artificial Intelligence Accelerates Molecular Vibration Analysis, Study Finds
July 1st 2025A new review led by researchers from MIT and Oak Ridge National Laboratory outlines how artificial intelligence (AI) is transforming the study of molecular vibrations and phonons, making spectroscopic analysis faster, more accurate, and more accessible.
AI and Dual-Sensor Spectroscopy Supercharge Antibiotic Fermentation
June 30th 2025Researchers from Chinese universities have developed an AI-powered platform that combines near-infrared (NIR) and Raman spectroscopy for real-time monitoring and control of antibiotic production, boosting efficiency by over 30%.
Nanometer-Scale Studies Using Tip Enhanced Raman Spectroscopy
February 8th 2013Volker Deckert, the winner of the 2013 Charles Mann Award, is advancing the use of tip enhanced Raman spectroscopy (TERS) to push the lateral resolution of vibrational spectroscopy well below the Abbe limit, to achieve single-molecule sensitivity. Because the tip can be moved with sub-nanometer precision, structural information with unmatched spatial resolution can be achieved without the need of specific labels.
Toward a Generalizable Model of Diffuse Reflectance in Particulate Systems
June 30th 2025This tutorial examines the modeling of diffuse reflectance (DR) in complex particulate samples, such as powders and granular solids. Traditional theoretical frameworks like empirical absorbance, Kubelka-Munk, radiative transfer theory (RTT), and the Hapke model are presented in standard and matrix notation where applicable. Their advantages and limitations are highlighted, particularly for heterogeneous particle size distributions and real-world variations in the optical properties of particulate samples. Hybrid and emerging computational strategies, including Monte Carlo methods, full-wave numerical solvers, and machine learning (ML) models, are evaluated for their potential to produce more generalizable prediction models.