A recent study explores the effectiveness of near-infrared (NIR) and ultraviolet-visible (UV-vis) spectroscopy in determining the time since deposition (TSD) of bloodstains, a critical aspect of forensic investigations. By comparing these two methods, researchers aim to improve the accuracy and reliability of bloodstain dating, with potential implications for real-world forensic applications.
In the field of forensic science, accurately determining the time since bloodstains were deposited at a crime scene is vital for reconstructing events and establishing timelines. Traditional methods, which relied on visual changes in blood color, have evolved into sophisticated analytical techniques, including spectroscopy. However, while UV-vis spectroscopy has been widely studied, there has been less focus on near-infrared (NIR) spectroscopy, despite its potential to overcome certain limitations of UV-vis methods. A recent study published in Talanta by researchers from the University of Genova seeks to address this gap by critically comparing the effectiveness of NIR and UV-vis spectroscopy in forensic bloodstain dating (1,2).
Read More: NIR in Bloodstain Analysis
The research, led by Sara Gariglio, Cristina Malegori, Alicja Menżyk, Grzegorz Zadora, Marco Vincenti, Monica Casale, and Paolo Oliveri from the Department of Pharmacy (DIFAR) at the University of Genova, aims to evaluate the applicability of NIR spectroscopy for estimating the age of forensic bloodstains. The study involved collecting capillary blood samples from volunteers, which were then aged over 16 days and repeatedly analyzed using both NIR and UV-vis spectroscopic methods. The study utilized classical preprocessing techniques like Savitzky-Golay derivatives and standard normal variate (SNV) transform, along with targeted strategies such as class centering, which was shown to be beneficial through principal component analysis (PCA). Finally, partial least squares (PLS) regression models were applied to assess the accuracy of both NIR and UV-vis spectroscopy in estimating the time since bloodstain deposition (1).
Yellow law enforcement tape isolating crime scene. Blurred view of city street, toned in red and blue police car lights | Image Credit: © New Africa - stock.adobe.com
The study’s findings revealed that both NIR and UV-vis spectroscopy demonstrated comparable performance in estimating the TSD of bloodstains, with root mean square errors of prediction (RMSEP) of approximately 40 hours for UV-vis and 55 hours for NIR spectroscopy. These results indicate an improvement in NIR spectroscopy compared to existing literature, suggesting that NIR could be a valuable tool in forensic bloodstain dating. Moreover, the study explored data fusion strategies, combining both spectroscopic methods to enhance the accuracy of TSD estimation. Mid-level data fusion showed promise, reducing the RMSEP to 35 hours under optimal conditions (1).
Despite the positive results, the study acknowledges the challenges of applying these methods in real-world forensic scenarios. NIR spectroscopy’s relative independence from preprocessing steps and its robustness make it more suitable for practical forensic applications, where environmental factors and other variables can complicate analysis. However, the research also highlights the potential of combining multiple spectroscopic techniques to achieve more accurate and reliable bloodstain dating (1).
The study concludes that NIR spectroscopy, when integrated with appropriate chemometric strategies, deserves increased recognition in the field of forensic bloodstain dating. While both NIR and UV-vis spectroscopy offer valuable insights into blood degradation processes, their combined use could lead to more accurate TSD estimation. However, further research is needed to refine these methods and develop standardized procedures that can be reliably applied in real forensic cases (1).
Exploring the synergies between different spectroscopic methods and advanced chemometric approaches, such as data fusion, holds promise for refining forensic practices and strengthening the reliability of age estimation in criminal investigations. The study sets the stage for future research aimed at bridging the gap between laboratory findings and real-world forensic challenges, ultimately enhancing the accuracy and effectiveness of forensic investigations.
This groundbreaking work by the University of Genova team not only advances the scientific understanding of bloodstain dating but also paves the way for more reliable forensic practices, contributing to the broader field of criminal justice (1,2).
(1) Gariglio, S.; Malegori, C.; Menżyk, A.; Zadora, G.; Vincenti, M.; Casale, M.; Oliveri, P. Determination of time since deposition of bloodstains through NIR and UV-Vis spectroscopy–a critical comparison. Talanta 2024, 278, 126444. DOI: 10.1016/j.talanta.2024.126444
(2) Liang, Y., Wu, J., Zeng, Q., Zhao, Y., Ma, K., Zhang, X., Yang, Q., Zhang, J. and Qi, Y. Rapid Identification of the Species of Bloodstain Based on Near Infrared Spectroscopy and Convolutional Neural Network-Support Vector Machine Algorithm. J. Braz. Chem. Soc. 2024, 35 (8), e-20240023. DOI: 10.21577/0103-5053.20240023
AI and Dual-Sensor Spectroscopy Supercharge Antibiotic Fermentation
June 30th 2025Researchers from Chinese universities have developed an AI-powered platform that combines near-infrared (NIR) and Raman spectroscopy for real-time monitoring and control of antibiotic production, boosting efficiency by over 30%.
Toward a Generalizable Model of Diffuse Reflectance in Particulate Systems
June 30th 2025This tutorial examines the modeling of diffuse reflectance (DR) in complex particulate samples, such as powders and granular solids. Traditional theoretical frameworks like empirical absorbance, Kubelka-Munk, radiative transfer theory (RTT), and the Hapke model are presented in standard and matrix notation where applicable. Their advantages and limitations are highlighted, particularly for heterogeneous particle size distributions and real-world variations in the optical properties of particulate samples. Hybrid and emerging computational strategies, including Monte Carlo methods, full-wave numerical solvers, and machine learning (ML) models, are evaluated for their potential to produce more generalizable prediction models.
Combining AI and NIR Spectroscopy to Predict Resistant Starch (RS) Content in Rice
June 24th 2025A new study published in the journal Food Chemistry by lead authors Qian Zhao and Jun Huang from Zhejiang University of Science and Technology unveil a new data-driven framework for predicting resistant starch content in rice
New Spectroscopy Methods Target Counterfeit Oral Medication Syrups
June 23rd 2025Researchers at Georgia College and Purdue University have developed a fast, low-cost method using Raman and UV–visible spectroscopy combined with chemometric modeling to accurately screen and quantify active ingredients in over-the-counter oral syrups, helping to fight counterfeit medications.