Scientists from Ben-Gurion University of the Negev in Beer-Sheva, Israel, the Afeka Tel-Aviv Academic College of Engineering in Tel-Aviv, Israel, and the Shamoon College of Engineering in Beer-Sheva, Israel recently created a system that combines Fourier transform infrared (FT-IR) spectroscopy with machine learning algorithms to identify bacteria that is resistant to antibiotics. Their findings were published in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy (1).
Close up the media plate on hand medical technicians working on bacterial culture and drug resistance of pathogens in laboratory. © analysis121980 - stock.adobe.com
Urinary tract infections (UTIs) are infections that occur when bacteria enter the urethra and infect the urinary tract. UTIs are the second most common type of infection in the body, resulting in more than 8 million doctor’s visits each year; furthermore, approximately 10 in 25 women and 3 in 25men will have UTI symptoms during their lifetime (2). These infections can affect different parts of the urinary tract, with the most common type being bladder infections (cystitis) and more severe cases leading to kidney infection (pyelonephritis) (3). Of the different bacterium that can cause UTIs, one of the most common is Klebsiella (K.) pneumoniae. This pathogen can use different mechanisms to create antibiotic-resistant mutants, making them resistant to multiple significant antibiotics.
Research has shown that a leading factor that contributes to the emergence of drug-resistant K. pneumoniae isolates is the transfer of plasmids and transposons containing resistance genes. These isolates can acquire multi-resistant plasmids and transposons, which can potentially spread to other bacteria and hasten the spread of multidrug-resistant (MDR) strains. This phenomenon has led to a need for rapid and precise methods to identify and determine bacterial susceptibility to antibiotics. Some methods, such as the Vitek 2 system and disc diffusion tests, can accomplish this, but they often rely on overnight culture and need a minimum of 48 hours to identify bacterial species that cause infection.
Fourier transform infrared (FT-IR) spectroscopy is a method capable of detecting minor molecular changes in cells, encompassing changes linked to the development of antibiotic resistance. This approach has been used across multiple fields to identify various biological samples, including bacteria and cancer cells. For this study, the scientists combined FT-IR spectroscopy with machine learning algorithms to identify K. pneumoinae directly from urine samples of UTI patients; simultaneously, the system helped determine the samples’ susceptibility to commonly prescribed antibiotics, all within approximately 40 min.
For the experiment procedures, 2333 bacterial samples, 636 of which were K. pneumoniae, were investigated using infrared micro-spectroscopy. 27966 spectra were obtained and analyzed with an XGboost classifier, which achieved a success rate of over 85% for identifying K. pneumoniae samples. As for the simultaneous determination of K. pneumoniae susceptibility to antibiotics, the sensitivities ranged between 74% and 81%. These findings highlight the potential this system has in mitigating the risks of bacterial resistance, although more research must be conducted in this regard.
(1) Abu-Aqil, G.; Suleiman, M.; Lapidot, I. et al. Infrared Spectroscopy-Based Machine Learning Algorithms for Rapid Detection of Klebsiella pneumoniae Isolated Directly from Patients' Urine and Determining its Susceptibility to Antibiotics. Spectrochim. Acta Part A: Mol. Biomol. Spectrosc. 2024, 314, 124141. DOI: https://doi.org/10.1016/j.saa.2024.124141
(2) Understanding UTIs Across the Lifespan. Urology Care Foundation 2016. https://www.urologyhealth.org/healthy-living/urologyhealth-extra/magazine-archives/summer-2016/understanding-utis-across-the-lifespan (accessed 2024-3-27)
(3) Urinary Tract Infection. U.S. Department of Health & Human Services 2024. https://www.cdc.gov/antibiotic-use/uti.html (accessed 2024-3-27)
AI and Dual-Sensor Spectroscopy Supercharge Antibiotic Fermentation
June 30th 2025Researchers from Chinese universities have developed an AI-powered platform that combines near-infrared (NIR) and Raman spectroscopy for real-time monitoring and control of antibiotic production, boosting efficiency by over 30%.
Toward a Generalizable Model of Diffuse Reflectance in Particulate Systems
June 30th 2025This tutorial examines the modeling of diffuse reflectance (DR) in complex particulate samples, such as powders and granular solids. Traditional theoretical frameworks like empirical absorbance, Kubelka-Munk, radiative transfer theory (RTT), and the Hapke model are presented in standard and matrix notation where applicable. Their advantages and limitations are highlighted, particularly for heterogeneous particle size distributions and real-world variations in the optical properties of particulate samples. Hybrid and emerging computational strategies, including Monte Carlo methods, full-wave numerical solvers, and machine learning (ML) models, are evaluated for their potential to produce more generalizable prediction models.
Polystyrene and UVC Sterilization Tested with Spectroscopy and Luminescence Tools
June 25th 2025A team of researchers from Spanish institutions has found that polystyrene used in healthcare packaging shows strong resistance to UVC sterilization, with minimal chemical degradation detected using FT-IR and Raman spectroscopy.
Combining AI and NIR Spectroscopy to Predict Resistant Starch (RS) Content in Rice
June 24th 2025A new study published in the journal Food Chemistry by lead authors Qian Zhao and Jun Huang from Zhejiang University of Science and Technology unveil a new data-driven framework for predicting resistant starch content in rice