A research team is claiming significantly enhanced accuracy of non-invasive blood-glucose testing by upgrading Fourier transform infrared spectroscopy (FT-IR) with multiple-reflections, quantum cascade lasers, two-dimensional correlation spectroscopy, and machine learning. The study, published in Spectrochimica Acta Part A, reports achieving a record-breaking 98.8% accuracy, surpassing previous benchmarks for non-invasive glucose detection.
Woman testing glucose level with traditional glucose monitor © Andrey Popov - stock.adobe.com
A study led by Liying Song, Zhiqiang Han, Po-Wan Shum, and Woon-Ming Lau has successfully transformed the accuracy of non-invasive blood-glucose testing. Conducted at Linyi University and the University of Science and Technology Beijing, the research integrates multiple technological advancements to overcome limitations in traditional Fourier transform-infrared (FT-IR)-based glucose testing (2).
Blood-Glucose Testing
Current non-invasive glucose testing methods rely on attenuated total reflection (ATR) combined with infrared spectroscopy, specifically ATR FT-IR, where infrared light is reflected from sample tissue using the ATR phenomenon to detect low signal glucose levels in a complex background. However, this approach struggles with sensitivity and interference from other biomolecules and from optical differences in tissues. To address these challenges, the research team implemented three key innovations: a multi-pass ATR reflections setup, quantum cascade laser (QCL) illumination, and advanced machine learning (ML) data analysis techniques (2).
Upgrading FT-IR for Superior Sensitivity
The first enhancement involved replacing the conventional single-pass ATR setup with a multiple-reflection ATR (MATR) configuration. This modification increased the signal-to-noise ratio by a factor of two to three, allowing for clearer glucose detection in complex biological tissue samples (2).
The second major enhancement replaced the traditional infrared lamp with a QCL, further tripling the signal-to-noise performance. The QCL, operating between 935 and 1128 cm⁻¹, precisely targeted glucose’s mid-infrared spectral signature, improving accuracy and reliability.
Leveraging Two-Dimensional Correlation Spectroscopy and AI
Beyond hardware improvements, the study leveraged two-dimensional correlation spectroscopy (2D-COS) to refine spectral analysis. Unlike traditional one-dimensional spectral methods, 2D-COS analyzes spectral variations across two wavelength axes, effectively minimizing interference from overlapping biomolecular signals (2).
To maximize analytical precision, the researchers also incorporated ML-based decision trees for hyperglycemia screening. They tested multiple algorithms, with a final approach combining three decision-tree models and a majority-voting mechanism. This strategy significantly improved classification performance, achieving an unprecedented 98.8% accuracy in distinguishing diabetic from non-diabetic glucose levels (2).
Extensive Testing and Validation
The study’s rigorous validation process involved 24 glucose concentrations (70–300 mg/dL) spanning both non-diabetic and diabetic ranges. Each concentration underwent 100 repeated spectral measurements, totaling 7,200 test spectra. The MATR-QCL-2D-COS combination yielded the best results, demonstrating not only high accuracy but also consistency across samples (2).
Implications for Diabetes Management
This research marks a notable step toward practical, non-invasive glucose monitoring solutions. By surpassing the accuracy benchmarks set by previous studies, including those requiring mechanical pressure for sampling, the upgraded FT-IR method could soon become a viable alternative to traditional blood-based glucose tests (2).
The integration of ML with advanced spectroscopic techniques opens new possibilities for rapid, painless, and highly accurate diabetes screening. As non-invasive technologies continue to advance, this breakthrough may pave the way for real-world applications in continuous glucose monitoring and early diabetes detection.
References
(1) National Institute of Diabetes and Digestive and Kidney Diseases (NIDDK) Diabetes Home Page. https://www.niddk.nih.gov/health-information/diabetes (accessed 2025-01-28)
(2) Song, L.; Han, Z.; Shum, P. W.; and Lau, W. M. Enhancing the Accuracy of Blood-Glucose Tests by Upgrading FTIR with Multiple-Reflections, Quantum Cascade Laser, Two-Dimensional Correlation Spectroscopy, and Machine Learning. Spectrochim. Acta A Mol. Biomol. Spectrosc. 2025, 327, 125400. DOI: 10.1016/j.saa.2024.125400
AI Boosts SERS for Next Generation Biomedical Breakthroughs
July 2nd 2025Researchers from Shanghai Jiao Tong University are harnessing artificial intelligence to elevate surface-enhanced Raman spectroscopy (SERS) for highly sensitive, multiplexed biomedical analysis, enabling faster diagnostics, imaging, and personalized treatments.
Toward a Generalizable Model of Diffuse Reflectance in Particulate Systems
June 30th 2025This tutorial examines the modeling of diffuse reflectance (DR) in complex particulate samples, such as powders and granular solids. Traditional theoretical frameworks like empirical absorbance, Kubelka-Munk, radiative transfer theory (RTT), and the Hapke model are presented in standard and matrix notation where applicable. Their advantages and limitations are highlighted, particularly for heterogeneous particle size distributions and real-world variations in the optical properties of particulate samples. Hybrid and emerging computational strategies, including Monte Carlo methods, full-wave numerical solvers, and machine learning (ML) models, are evaluated for their potential to produce more generalizable prediction models.