News|Articles|November 25, 2026

FDA Expands Clearance of Thermo Fisher's EXENT Mass Spectrometry System to Myeloma Monitoring

Listen
0:00 / 0:00

Key Takeaways

  • FDA clearance now covers serial monitoring, enabling MS-based M-protein tracking for response assessment and relapse detection in multiple myeloma and Waldenström’s macroglobulinemia.
  • This expands the 2025 510(k) indication beyond diagnosis, addressing prior limitations around post-diagnostic, long-term follow-up performance claims.
SHOW MORE

The expanded intended use takes the MALDI-TOF-based platform beyond aiding diagnosis to tracking monoclonal proteins over time in patients with multiple myeloma and Waldenström's macroglobulinemia.

In a press release today, Thermo Fisher Scientific (Waltham, Massachusetts) announced that the U.S. Food and Drug Administration (FDA) has cleared an expanded intended use for its EXENT Analyser with the EXENT GAM Assay.1 Because of this new clearance, clinical laboratories can now use the mass spectrometry (MS)-based system to help monitor disease status and treatment response in patients with multiple myeloma and Waldenström's macroglobulinemia.1

This decision expands a clearance granted last year. In 2025, the FDA gave 510(k) clearance to the EXENT Analyser and Immunoglobulin Isotypes (GAM) Assay to aid in the diagnosis of multiple myeloma and related disorders.2 At the time of this announcement, Thermo Fisher described it as an automated MALDI-ToF mass spectrometry platform for clinical laboratories.2,3 When that clearance was announced, Thermo Fisher cautioned that the system's performance had not been formally evaluated after diagnosis, for example in long-term monitoring.4 The new clearance covers that use.1,2

Why is it important to monitor multiple myeloma and Waldenström's macroglobulinemia?

Monitoring multiple myeloma and Waldenström's macroglobulinemia are monoclonal gammopathies, which means that managing them depends on repeated measurement of monoclonal protein (M-protein) levels to assess disease status and treatment response and to detect relapse.1 After diagnosis, it is common that patients are monitored for M-protein levels for the rest of their lives. According to the National Cancer Institute figures, there have been an estimated 36,000 new cases of multiple myeloma in the United States this year.1

According to Thermo Fisher Scientific, conventional methods can struggle when M-protein concentrations are low or when therapeutic antibodies interfere with interpretation. Within its cleared intended use, Thermo Fisher said, the EXENT system is designed to detect and track M-proteins over time, including at low concentrations.1 The system is also designed to distinguish disease-related proteins from certain known therapeutic antibodies.1 The company added that the system can follow a patient's disease as it changes, including while the immune system recovers after therapy.1

How does the EXENT Analyser work?

The EXENT Analyser pairs automated immunoassay with matrix-assisted laser desorption/ionization time-of-flight (MALDI-ToF) mass spectrometry readout. It has two main modules: the EXENT-iP500, a liquid handler that prepares samples by magnetic bead immunoprecipitation, and the EXENT-iX500 MALDI-ToF mass spectrometer, which analyzes them.3 FDA records describe a workflow that uses isotype-specific antibodies to identify and semi-quantify monoclonal IgG, IgA, and IgM in serum.3

According to the company, the system requires no prior MS expertise. Laboratories already running it for diagnostic testing can apply the same workflow to ongoing monitoring, so one platform can follow a patient from diagnosis through disease management.1

"For patients living with multiple myeloma or Waldenström's macroglobulinemia, understanding how their disease is responding to treatment is critical," said Stephen Harding, vice president and general manager, protein diagnostics, Thermo Fisher Scientific.1 "This expanded clearance brings the precision of mass spectrometry beyond diagnosis and into ongoing monitoring, giving clinicians greater insight into disease status and treatment response."

Why does this clearance matter for clinical laboratories?

For clinical laboratory work, this clearance moves a MALDI-TOF assay further in this work, which has mostly relied on electrophoretic and immunochemical methods to measure M-protein.1 With FDA clearance for both diagnosis and monitoring, labs that have adopted EXENT can run serial testing on the same instrument, without validating a separate method for follow-up samples. Thermo Fisher has not released performance data specific to the monitoring indication.

References
  1. Business Wire, Thermo Fisher Scientific Expands Clinicians' Ability to Monitor Multiple Myeloma with First-of-Its-Kind FDA Clearance. Business Wire, 2026. https://www.businesswire.com/news/home/20261124848896/en/Thermo-Fisher-Scientific-Expands-Clinicians-Ability-to-Monitor-Multiple-Myeloma-with-First-of-Its-Kind-FDA-Clearance (accessed November 24, 2026).
  2. Thermo Fisher Scientific. Thermo Fisher Scientific Receives 510(k) Clearance in the United States for EXENT System to Aid in the Diagnosis of Multiple Myeloma. https://www.thermofisher.com/bindingsite/us/en/news/exent-system-united-states-diagnosis-clearance.html (accessed November 24, 2026).
  3. U.S. Food and Drug Administration, 510(k) Premarket Notification K250159. U.S. FDA, 2026. https://www.accessdata.fda.gov/cdrh_docs/pdf25/K250159.pdf (accessed November 24, 2026).
  4. Eleazar, A. FDA Authorizes EXENT System to Aid Myeloma Diagnosis. Targeted Oncology, 2025. https://www.targetedonc.com/view/fda-authorizes-exent-system-to-aid-myeloma-diagnosis (accessed November 24, 2026).

Related to this article

Update: AI and Machine Learning for Spectral Analysis. ©   Mehbubakhatun-chronicles-stock.adobe.com
Artificial intelligence (AI) has moved from a supporting role in molecular spectroscopy to the center of how spectra are interpreted. Between 2023 and 2026, machine learning models began proposing full molecular structures from routine NMR spectra, learning chemistry from millions of unlabeled mass spectra, predicting UV–vis absorption from structure alone, and steering workflows in autonomous laboratories. This review covers those advances, the push for explainable models, and what still limits routine adoption.
Curated 2026 Evergreen Content from Spectroscopy. ©  Chanakarn -chronicles-stock.adobe.com
Spectroscopy's editors gather 143 evergreen articles from 2026, including tutorials, terminology guides, technique reviews, application surveys, peer-reviewed research and the magazine's long-running columns, and organize them by subject so readers can build lasting knowledge one topic at a time.