Register Now: Advances in Spectroscopy for Pharma and Biopharmaceutical Analysis Symposium
News|Articles|November 23, 2026

SciX 2026 Recap: Raman Spectroscopy Moves Toward the Clinic

Listen
0:00 / 0:00

Key Takeaways

  • Hospital adoption of Raman requires reproducible instrumentation, validated software, regulatory readiness, and trustworthy AI that converts spectra into actionable clinical decisions for nonexpert operators.
  • Fiber-based Raman probes target real-time tumor margin assessment, while host-response Raman diagnostics aim for 10–15-minute sepsis guidance, anticipating future “optical digital twins” integrating molecular and wearable physiological data.
SHOW MORE

Award winners at SciX 2026 described how Raman, LIBS, and single-particle techniques are moving from proof of concept toward real-world use.

Last month, spectroscopy researchers, industry professionals, vendors, and students gathered in Sparks, Nevada, for the 2026 SciX Conference. As part of our coverage of the conference, we sat down with some the leaders in analytical spectroscopy, asking them about their research and how the current trends and advancements in spectroscopy are impacting their work.1–7

They also documented some of the pressing challenges, which include turning measurements into clinical decisions, managing enormous data sets, and interpreting what spectra actually mean.

Using Raman Spectroscopy In Hospitals

To start, Raman spectroscopy and its role in clinical applications continues to grow. Jürgen Popp, scientific director of the Leibniz Institute of Photonic Technology (IPHT) in Jena, Germany, and receiver of the 2026 Ellis R. Lippincott Award, described what it takes to move Raman spectroscopy from the research bench into hospitals.2 Popp discussed how clinical systems need consistent hardware, robust software, and results that nonspecialist staff can act on.

“In the lab, you can readjust everything quite easily, but if you are in a clinical environment, it just has to work,” Popp said.2

Popp’s group is currently developing fiber Raman probes that could help surgeons assess tumor margins during an operation. It is also working on a host-response test that could provide sepsis guidance in approximately 10–15 minutes.2 Further out, Popp envisions an optical digital twin that adds molecular data to the physiological data wearables already collect, a goal he estimates is about a decade away.2 Achieving it, Popp said, will depend significantly on regulation, cloud infrastructure, and software.

“It’s about the software; we need trustworthy AI,” Popp said.2

Other iterations of Raman spectroscopy, such as surface-enhanced Raman spectroscopy (SERS), are also being brought to the hospital. Marc Porter, Distinguished Professor Emeritus at the University of Utah, concurred with Popp that regulation, cloud infrastructure, and software will determine whether Raman spectroscopy is integrated into hospital workflows.6

Porter’s group works on SERS immunoassays, which includes a tuberculosis test being commercialized with a company in England.

“We wanted this to be a technology pull by them and not a technology push by us in the laboratory,” Porter said of working with clinicians.6 At picomolar and femtomolar levels, he added, sample preparation dominates.

“The pre-analytics, as our clinical colleagues talk about it, mean everything,” Porter said.6

Seeing Beneath the Surface

Sara Miller, a vibrational spectroscopist at Flinders University in Australia, accepted the inaugural Peter Griffiths Award for best paper in Applied Spectroscopy Practica.5 Her coauthors were Mitchell C. Chalmers, Teemu Tomberg, and Keith Gordon, and their study used deep low-frequency Raman spectroscopy to distinguish model breast microcalcifications embedded at different depths in wax.

“A mammogram’s really good at detecting the microcalcifications, but it can’t distinguish whether it is likely to be benign or malignant,” Miller said.5

A defocused, micro-spatially offset configuration performed best, with an area under the curve (AUC) of 0.94 in the low-frequency region.5 Miller also outlined next steps in this work, including more realistic tissue phantoms, a portable probe, and clinical data.

When Data Becomes the Bottleneck

Kevin Wilkinson, a professor of environmental chemistry at the Université de Montréal, received the Lester W. Strock Award at SciX and he talked about the bottlenecks the industry is seeing in data analysis. Wilkinson explained how faster instrumentation is the culprit of this trend has been.3 Outlining his work as an example, Wilkinson explained how his group analyzed hundreds of thousands of airborne particles and detected up to 21 elements in individual particles.3 They found metalloids about 6 km downwind, but telling engineered nanoparticles apart from natural ones still requires combining techniques.3

Meanwhile, Siddhartha Das of the University of Maryland, winner of the AES Mid-Career Award, talked about his work using all-atom molecular dynamics simulations to study how ions and water behave in nanochannels grafted with polymer brushes. He relied on machine learning to parse the resulting data sets.4 His simulations revealed an effect in which energy generation and flow enhancement occur together.4

And finally, Alessandro De Giacomo, a professor at the University of Bari Aldo Moro and editor-in-chief of Spectrochimica Acta Part B, discussed nanoparticle-enhanced laser-induced breakdown spectroscopy (LIBS) and a drone-based LIBS system that calibrates itself in flight, reaching quantitative accuracy of about 0.1%.7

“With this self-calibration, everything is done in the measurement,” De Giacomo said.7

The Next Generation’s Puzzle

One of the other, ancillary focuses at SciX was what the next generation needs to do to take spectroscopy research to the next step. Jay Kitt, the 2026 Spectroscopy Emerging Leader in Molecular Spectroscopy and director of chemistry at Litmus Analytical, argued that hardware is no longer the main obstacle.

“I think that my generation is at a point where the instrumentation is really nailed down,” Kitt said.1 In his view, the unmet need is the biochemical interpretation of Raman spectra, where machine learning and AI could help link band changes to biological mechanisms.1

References
  1. Kitt, J.; Wetzel, W. Quantitative Raman Spectroscopy and the Unsolved Puzzle of Spectral Interpretation. Spectroscopy Online, 2026. https://www.spectroscopyonline.com/view/quantitative-raman-spectroscopy-and-the-unsolved-puzzle-of-spectral-interpretation (accessed November 17, 2026).
  2. Popp, J.; Wetzel, W. The Latest in Surgical Raman Probes, Sepsis Diagnostics, and the Personalized Optical Twin. Spectroscopy Online, 2026. https://www.spectroscopyonline.com/view/the-latest-in-surgical-raman-probes-sepsis-diagnostics-and-the-personalized-optical-twin (accessed November 17, 2026).
  3. Wilkinson, K.; Wetzel, W. Why Big Data Is Transforming Environmental Nanoparticle Analysis. Spectroscopy Online, 2026. https://www.spectroscopyonline.com/view/why-big-data-is-transforming-environmental-nanoparticle-analysis (accessed November 17, 2026).
  4. Das, S.; Wetzel, W. Rethinking Electroosmosis Atom by Atom and Water–Ion Interactions. Spectroscopy Online, 2026. https://www.spectroscopyonline.com/view/rethinking-electroosmosis-atom-by-atom-and-water-ion-interactions (accessed November 17, 2026).
  5. Miller, S.; Wetzel, W. How Deep Low-Frequency Raman Could Detect Breast Microcalcifications. Spectroscopy Online, 2026. https://www.spectroscopyonline.com/view/how-deep-low-frequency-raman-could-detect-breast-microcalcifications (accessed November 17, 2026).
  6. Porter, M.; Wetzel, W. From Raman Labels to the Clinic. Spectroscopy Online, 2026. https://www.spectroscopyonline.com/view/from-raman-labels-to-the-clinic (accessed November 17, 2026).
  7. De Giacomo, A.; Wetzel, W. The Growing Utility of LIBS in Science. Spectroscopy Online, 2026. https://www.spectroscopyonline.com/view/the-growing-utility-of-libs-in-science (accessed November 17, 2026).

Related to this article

Curated 2026 Evergreen Content from Spectroscopy. ©  Chanakarn -chronicles-stock.adobe.com
Spectroscopy's editors gather 143 evergreen articles from 2026, including tutorials, terminology guides, technique reviews, application surveys, peer-reviewed research and the magazine's long-running columns, and organize them by subject so readers can build lasting knowledge one topic at a time.
Healthcare administrator reviewing an insurance policy schedule with a stethoscope on a clipboard, health insurance coverage, medical underwriting, prior authorization, and patient claims processing. | Image Credit: Joi_studio - stock.adobe.com
In a SciX interview, Marc Porter covered a lot of ground, from a student-driven pivot into immunoassays to a baseball analogy for Stokes and anti-Stokes scattering, and shares the open questions he is still chasing.
Spectral Frontiers: Seeing the Unseeable Microspectroscopy
Microspectroscopy, the marriage of spectroscopic chemical identification with microscopic spatial resolution, has advanced from Perkin-Elmer's first commercial infrared microspectrometer in 1953 to today's nanoscale AFM-IR probes, synchrotron-brightness infrared beamlines, and compact hyperspectral tissue imaging devices being developed for AI-assisted cancer detection.