Taking Raman Spectroscopy from the Lab to the Clinic
Jürgen Popp of Leibniz-IPHT discusses what it takes to move biospectroscopy into hospitals, from regulation and cost targets to Raman-guided surgery and a future “personalized optical twin.”
Jürgen Popp of the Leibniz Institute of Photonic Technology (Leibniz-IPHT) in Jena, Germany, has spent more than two decades applying vibrational spectroscopy to infection and cancer diagnostics. Reflecting on his award, he credited the PhD students, engineers, technicians, and clinical partners who have shaped the work, calling it a prize for the entire team.
Popp described the move from laboratory to clinic as a multifaceted challenge. Hospital settings demand robust, stable hardware and reliable software, techniques that can be run by trained personnel rather than chemists or physicists, and results translated into information clinicians can act on rather than raw Raman spectra. Europe’s Medical Device Regulation adds another hurdle; his team spent roughly €300,000 to €400,000 on documentation before a first human study with its INVAScope system, though Popp now sees that experience as an asset.
Adoption also depends on fitting existing clinical workflows and costing less than the gold standard. For pathogen and antimicrobial resistance testing, Popp’s group is targeting a device priced at €5,000 to €10,000 and a test costing a euro or less, down from €10 to €15 per test today. A separate host-response test could tell emergency physicians within 10 to 15 minutes whether a severe infection is bacterial, fungal, or viral, reducing reliance on broad combination therapy.
In head and neck surgery at Jena University Hospital, surgeons use a sterilizable Raman probe to assess tumor margins. After initial training, they now acquire a good spectrum in about one minute, and the approach could replace time-consuming frozen section analysis without otherwise changing the workflow.
Looking ahead, Popp outlined a “
Further Reading
- Popp, J.; Mayherhofer, T. G.; Borowsky, A.; Schmitt, M.; Meier-Ewert, L.; Hamm, G. From Molecular Snapshots to Longitudinal Prevention: The Personalized Optical Digital Twin. Spectroscopy Online, 2026.
https://www.spectroscopyonline.com/view/from-molecular-snapshots-to-longitudinal-prevention-the-personalized-optical-digital-twin (accessed October 15, 2026). - Popp, J.; Workman, J., Jr.; Wetzel, W. Jürgen Popp on Bringing Raman Diagnostics From the Laboratory to the Clinic. Spectroscopy Online, 2026.