Using Nano-FT-IR Spectroscopy to Study Central African Wooden Sculptures

Author(s)Will Wetzel

A study from Vanderbilt University used nano Fourier-transform infrared (FT-IR) spectroscopy to study central African wooden sculptures and learn more about material composition.

In archaeology and cultural heritage, preserving valued artifacts is of utmost importance. Protecting the integrity of these objects allows researchers and scientists to study them to learn about the ancient past, including what the artifacts were made of and what they were used for.

Cultural heritage is a burgeoning field. Artifacts under study require meticulous care, especially when it comes to analyzing material composition. Any sample extracted for study must be minimal to maintain the artifact’s integrity (1). Ideally, the techniques employed should be nondestructive to ensure that samples can be reused for future analyses (1).

The Journal of Raman Spectroscopy capitalized on the growing number of researchers conducting investigations in this field, highlighting several studies that used Raman spectroscopy (2). As a nondestructive technique, Raman spectroscopy is best suited for this type of analysis, especially when coupled with portable X-ray fluorescence (pXRF) spectroscopy (2).

However, despite advancements in the field, there are still limitations with optical detection limits. Because they are limited by the diffraction limit of light, spatial resolution is constrained (1). As a result, this is a challenge because many material-specific properties essential for identification rely on molecular vibrations and conductivity, necessitating spectral analysis in the infrared (IR) spectrum (1).

A recent study led by Joshua Caldwell at Vanderbilt University, published in ACS Photonics, explored a new approach that is designed to alleviate the above concerns, involving a spectroscopic technique called nano Fourier-transform infrared (nano-FT-IR) spectroscopy.

Characterized by its long wavelengths, infrared (IR) light complicates the identification process, especially when sample compositions vary at the nanometer scale (1). Nano-FT-IR is a solution to this problem because it allows for FT-IR-like detection at a subdiffraction spatial resolution of approximately 20 nanometers (1).

Like Raman spectroscopy, nano-FT-IR is also nondestructive. It minimizes the need for extensive sample extraction, allowing individual samples to be examined using multiple complementary methods (1). To demonstrate the feasibility of nano-FT-IR spectroscopy in cultural heritage applications, Caldwell and his team used the technique to analyze surface coatings from African wood sculptures. These sculptures present a significant challenge because of the submicrometer scale of some of their layers, which complicates the interpretation of cross-sectional compositions using established techniques (1).

Caldwell’s team demonstrated that nano-FTIR could effectively identify functional groups corresponding to various classes of organic coatings and inorganic pigments through point spectra analysis (1). They showed that Nano-FT-IR offers a promising alternative for collecting IR spectra with minimal sample preparation, addressing the limitations of far-field vibrational spectroscopies (1). Traditional techniques come with challenges, such as a diffraction limit and complex sample preparation, which can compromise data quality and layer stratigraphy in cultural heritage research (1). Nano-FTIR's high-resolution, label-free chemical identification allows for precise analysis of thin material layers in heterogeneous mixtures, preserving the integrity of the sample while providing detailed material composition (1).

Furthermore, the research conducted at Vanderbilt University shows how the integration of advanced technology with art conservation demonstrated the interdisciplinary approach required to tackle complex problems (1). It also underscores the importance of ongoing innovation in preserving our cultural heritage for future generations. Because of this study, researchers and those specialized in handling cultural artifacts have access to a study that could aid them in their work.

References

(1) Diaz-Granados, K.; Price, R.; McBride, J. R.; Moffett, D.; Kavich, G. M.; Caldwell, J. D. Identification of Surface Coatings on Central African Wooden Sculptures Using Nano-FTIR Spectroscopy. ACS Photonics 2024, ASAP. DOI: 10.1021/acsphotonics.4c00320

(2) Workman, Jr., J. Raman Spectroscopy Transforms Cultural Heritage and Forensic Analysis. Spectroscopy. Available at: https://www.spectroscopyonline.com/view/raman-spectroscopy-transforms-cultural-heritage-and-forensic-analysis (accessed 2024-07-29).


Related to this article

Spectroscopy Top 10 DOI Articles of the Month (October 2026)
The following articles are the most accessed digital object identifier (DOI) manuscripts for Spectroscopy and LCGC International during the month of October 2026. Nine articles are individually ranked here by DOI page views; the seventh-highest entry (99 views) was recorded against the bare LCGC North America journal-level DOI rather than an individual article and is therefore not attributable to a single manuscript.
Optical and Electronic Instrument Components,  ©  ridwan -chronicles-stock.adobe.com
The updated and expanded 2026 edition of Spectroscopy's Instrument Components Terminology Guide defines the sources, detectors, optical and dispersive elements, sampling hardware, physical constants, and unit conversions used across UV-vis, NIR, IR, Raman, X-ray, and atomic spectroscopic instrumentation, with new terms reflecting component developments reported between 2022 and 2026.
Curated 2026 Evergreen Content from Spectroscopy. ©  Chanakarn -chronicles-stock.adobe.com
Spectroscopy's editors gather 143 evergreen articles from 2026, including tutorials, terminology guides, technique reviews, application surveys, peer-reviewed research and the magazine's long-running columns, and organize them by subject so readers can build lasting knowledge one topic at a time.
Highly Substituted Benzene Rings—The Rest of the Story II: Spectra
This column, the second installment on highly substituted benzene rings, shows that tri- and tetra-substituted substitution patterns can be distinguished by whether the ring-bending peak is present and by the position of the in-phase aryl C-H wagging peak, which shifts according to how many adjacent hydrogens the ring carries.
Spectral Frontiers: Seeing the Unseeable Microspectroscopy
Microspectroscopy, the marriage of spectroscopic chemical identification with microscopic spatial resolution, has advanced from Perkin-Elmer's first commercial infrared microspectrometer in 1953 to today's nanoscale AFM-IR probes, synchrotron-brightness infrared beamlines, and compact hyperspectral tissue imaging devices being developed for AI-assisted cancer detection.
Mapping Molecular Mobility Pixel by Pixel
Garth Simpson of Purdue University explains how patterned photobleaching and spatial Fourier transforms can turn a single-point measurement into a diffusion coefficient at every pixel in the field of view.