Register Now: Advances in Spectroscopy for Pharma and Biopharmaceutical Analysis Symposium
|Articles|December 1, 2014

Spectroscopy Supplements

  • Special Issues-12-01-2014
  • Volume 29
  • Issue 12

WITec GmbH

Company Description

WITec is a manufacturer of high-resolution optical and scanning probe microscopy solutions for scientific and industrial applications. A modular product line allows the combination of different microscopy techniques such as Raman, NSOM, or AFM in one instrument. The company's product line features a near-field scanning optical microscope, using unique cantilever technology, a confocal Raman microscope designed for highest sensitivity and resolution, and an AFM for material research and nanotechnology. Focusing on innovations and constantly introducing new technologies, WITec is the leading expert for a wide variety of optical, structural, and chemical imaging tasks.

Chief Spectroscopic Techniques Supported

  • Raman spectroscopy

  • Confocal 3D Raman imaging

  • Ultrafast confocal Raman imaging

  • Confocal and near-field fluorescence spectroscopy

  • Upgradeable with atomic force and near-field microscopy capabilities

  • Topographic Raman imaging

  • RISE microscopy (Raman imaging & scanning electron microscopy)

Markets Served

WITec products are delivered worldwide to academic and industrial research labs focusing on high-resolution chemical imaging and materials characterization. Areas of application for WITec's confocal Raman imaging systems include polymer sciences, pharmaceutics, life science, geoscience, thin films and coating analysis, semiconductors, and nanotechnology.

Major Products/Services

WITec alpha300 Confocal Raman Microscope: The alpha300 R is a Raman imaging system focusing on high-resolution as well as high-speed spectra and image acquisition. The acquisition time for a single Raman spectrum is in the range of 1 ms or even below; thus, a complete Raman image consisting of tens of thousands of spectra can be obtained in 1 min or less. Differences in chemical composition, although completely invisible in the optical image, will be apparent in the Raman image and can be analyzed three-dimensionally with a resolution down to 200 nm.

WITec alpha500 Automated Confocal Raman & Atomic Force Microscope: The alpha500 is an automated confocal Raman and atomic force microscopy system incorporating a motorized sample stage for large samples and customized multi-area/multi-point measurements. It allows nondestructive chemical imaging with confocal Raman microscopy as well as high-resolution topography imaging with AFM using the integrated piezo scan-stage. Both modes can be run fully automatically, guaranteeing the most comprehensive surface inspection possibilities for systematic and routine research tasks or high-level quality control.

Facilities

WITec Headquarters is located in Ulm, Germany, and includes the R&D department, production, sales and marketing, and administration. WITec Instruments Corp. in Knoxville, Tennessee, is responsible for North American sales and service activities.

WITec GmbH
Main Address:
Lise-Meitner-Str. 6, 89081
Ulm, Germany

WITec Instruments Corp.
130G Market Place Blvd.
Knoxville, TN 37922

TELEPHONE
+49 (0) 731 140 700
US: (865) 984-4445

FAX
+49 (0) 731 140 70200
US: (865) 984-4441

E-MAILinfo@witec.de

WEB SITEwww.www.witec.de

NUMBER OF EMPLOYEES
40

YEAR FOUNDED
1997


Related to this article

Pittsburgh, Pennsylvania, USA. Beautiful Pittsburgh at twilight. | Image Credit: © checubus - stock.adobe.com
Organized by CPACT, the April 27 to 29 meeting at the Marriott Pittsburgh City Center will bring together scientists, engineers, and vendors across the process industries, with keynotes on PAT, Raman, and NIR applications and an abstract deadline of December 7, 2026.
Abstract concept of connecting molecules DNA network vector neurons | Image Credit: © bill2499 - stock.adobe.com
Garth Simpson of Purdue University outlines plans to survey more ordered molecular assemblies and to apply interface-specific chiral spectroscopy to enzyme reactors, solid-phase synthesis, spin-selective reactions, and, ultimately, a new analytical method.
Curated 2026 Evergreen Content from Spectroscopy. ©  Chanakarn -chronicles-stock.adobe.com
Spectroscopy's editors gather 143 evergreen articles from 2026, including tutorials, terminology guides, technique reviews, application surveys, peer-reviewed research and the magazine's long-running columns, and organize them by subject so readers can build lasting knowledge one topic at a time.