Appendix VIII: NIR

Author(s)Howard Mark

Additional information from the NIR section of the Pittcon Review article.

Manufacturer: ABB Analytical Measurements

ca.abb.com

Product name: TALYS ASP500

FT-NIR spectrometer

Used for: Process analysis

Measurement Mode: transmission, transflectance, diffuse reflectance

Special Features: Minimal footprint, shelf- or wall-mounted additional enclosure, embedded processor, continuous monitoring for analysis results and instrument health, standard Ethernet communication link, multiple language capability, variable sample configuration. A USB key interface to update analysis configuration

Software: FTSW100. 21CFR11 compliant, May be used in other equipment (other ABB process analyzers)

Suggested applications: Real-time control of chemical processes, reactor profiling, real-time determination of process end-point, cycle-time reduction, process characterization and early troubleshooting.

Primary benefits: design is optimized to minimize the complexity associated with process equipment implementation.

Unique features: Embedded processor, touch screen, multiple languages, minimal footprint, shelf- or wall-mounted, switch between 3 different process configurations with up to 5 properties per chemistry, ease of use and implementation, seamless transfer between ABB laboratory and process analyzers or between ABB process analyzers

Manufacturer: BaySpec, Inc.

bayspec.com

Product name: SuperGamut NIR Spectrometer

NIR spectrometer

New this year: Highly efficient Volume Phase Grating (VPG) as the spectral dispersion element and an ultra-sensitive InGaAs array detector as the detection element, thereby providing high-speed parallel processing and continuous spectrum measurements. Benefiting from experience manufacturing high-volume optical channel performance monitoring device for the telecommunications industry, BaySpec's NIR spectral devices utilize low-cost field proven components. For the first time in instrumentation history an affordable, accurate and ruggedized spectral device is a reality.

Used for: Lab, process analysis

Measurement Mode: Transmission, reflection

Special Features: outstanding optical throughput, compact size, no moving parts, fast response time

Software: Spec 20/20 and SDK supported Available as separate product, 21CFR11 compliant, cGMP compliant, May be used in other equipment, Compatible with other manufacturers' equipment.

Suggested applications: Blender, moisture monitoring; pharmaceutical, medical diagnostics; beverage, food, diary, water safety; content uniformity; raw material ID; In-line/ at-line/ on-line process control; narcotics, counterfeit detection.

Primary benefits: best-in-class performance, long-term reliability, compact size and ultra-low power consumption.

Unique features: Ultra-reliable and highly-efficient Volume Phase Grating (VPG), Fast f/2 optics for improved throughput, No moving parts for high mechanical stability and low phase noise

Manufacturer: Bruker Optik GmbH

www.bruker.com

Product Name: TANGO FT-NIR Spectrometer

FT-NIR Spectrometer

Used For: Lab, Process analysis

New this year: This is a brand new FT-NIR Spectrometer

Dimensions: 19 kg

Measurement Mode: Background measurements, Transmission measurements, Reflection measurements

Special features: Battery pack optional, embedded PC with 10.5" touch screen display.

21CFR11 compliant, may be used in other equipment.

Suggested Applications: Food and Beverage, Feed Manufacturing, Pharma & Biotechnology, Chemical and Petrochemical, Polymer Industry

Primary benefits: high performance spectrometer, designed to work with any existing calibration method. The touch screen developed for the routine user.

Unique features: Has embedded computer and touch screen display for push button operation.

Manufacturer: B&W Tek, Inc.

bwtek.com

Product name: Exemplar

NIR Spectrometer

New this year: The first smart spectrometer featuring on board data processing, USB 3.0 communication, and temperature compensation.

Used for: Lab, Process, Hand-held/portable operation

Dimensions: 3.98 x 2.48 x 1.61inches (101 x 63 x 41 mm)

Measurement Mode: Absorbance / Reflectance / Transmittance over Fiber Optic

Specialty accessory description: A wide range of fiber- optically coupled accessories are available: light sources, sample holders, fibers & probes, and integrating spheres.

Special Features: embedded processor, "SuperSpeed" USB 3.0 communication, multichannel capabilities (up to 18 simultaneous channels), a 2048 element detector, built-in 16-bit digitizer with greater than 2.0 MHz readout speed.

Software: BWSpec included with all B&W Tek products

Available as separate product, may be used in other equipment, compatible with other manufacturers' equipment

Suggested applications: UV, Vis, and NIR spectroscopy and spectroradiometry, spectrophotometry, kinetic reaction monitoring, transient spectral analysis, wavelength identification, OEM systems iIntegration

Primary benefits: transfer up to 900 spectra per second, supports up to 32 devices, low trigger delay (14 ns) & gate jitter (+/- 1ns)

Unique features: Temperature Compensation, 1ms Minimum Integration Time, < 0.5nm Spectral Resolution, UV - NIR spectyral range (200nm - 1050nm), >2.0 MHz Readout Speed

Manufacturer: B&W Tek, Inc.

bwtek.com

Product name: Exemplar Plus

NIR Spectrometer

New this year: A high performance smart spectrometer utilizing an unfolded Czerny-Turner spectrograph.

Used for: Lab, Process, Hand-held/portable operation

Dimensions: 7.40 x 5.05 x 2.80 inches (188 x 128 x 71 mm)

Measurement Mode: Fiber Optic

Specialty accessory description: A wide range of fiber- optically coupled accessories available: light sources, sample holders, fibers & probes, and integrating spheres.

Special Features: Same as Exemplar, above, in addition to: TE Cooled back-thinned (BT) CCD detector, long focal length, 190-1100nm spectral range, built-in shutter, resolutions from 0.1 nm to 10.0 nm.

Software: BWSpec included with all B&W Tek products. Available as separate product, may be used in other equipment, compatible with other manufacturers' equipment

Suggested applications: Low Light Level UV to NIR spectroscopy, raman and fluorescence spectroscopy, on-line process monitoring, LCD display measurement, biomedical spectroscopy, gas and water analysis, LED characterization

Primary benefits: Transfer up to 900 spectra per second, supports up to 32 devices, low trigger delay (14ns) & gate jitter (+/- 1ns)

Unique features: High UV, Vis, and NIR response, 2048 detector elements, Over 60% QE at 200 nm, 0° TE cooling (default), over 90% peak QE, built-in shutter

Manufacturer: EssentOptics Ltd

essentoptics.com

Product name: PHOTON RT

Scanning spectrophotometer

Features: The first spectrophotometer on the market designed specifically to run wide range of optical measurements of parts with thin film coatings – transmittance, reflectance, polarization dependent measurements in wide angular and spectral range, average polarization (S+P)/2, optical density 0-4D, etc. All measurements are done automatically and without any additional external fixtures or accessories.

New this year: Expanded spectral range to 190-4000 nm which is presently the widest range on the market for such product. Added new feature – average polarization measurement, redesigned interface for more easy and convenient operation.

Used for: Lab, Process analysis

Literature included: Operation manual

Measurement Mode: Transmittance, reflectance, angular dependent measurements, polarization dependent measurements, optical density, integral values

Suggested applications: Optical measurement of parts with coatings – all types of optical filters, mirrors, AR coatings, cube polarizers etc in UV, VIS and NIR range (190-4000 nm)

Primary benefits: The instrument offers a surprisingly easy and convenient way to measure optics with coatings – fast, trustful, and no additional costly fixtures. The product is focused specifically on optics. Other products on the market are "adopted" for this application by using a standard spectrophotometer for chemical and biochemical applications and a number of delicate and expensive fixtures.

Unique features: All measurement features are build-in (no fixtures). The instrument is designed just for optics so it does not have any elements not related to this application – neither in design, nor in software.

Manufacturer: FITNIR Analyzers Inc.

fitnir.com

Product name: FITNIR Benchtop

Near-infrared spectrometer

New this year: A benchtop version of its online near-infrared analyzer, using the same optical technology as its online analyzer. A compact plug and play unit.

Used for: Lab, Process analysis

Measurement Mode: Transmission

Special Features: Heated vial holder with use of disposable vials (benchtop analyzer)

Software: 21CFR11 compliant, cGMP compliant

Suggested applications: pulp liquor in pulp processing industry, Si, Ca, and Mg to indicate water hardness in oil sands industry, MeOH and Turpentine in condensates, COD in brownstock filtrates, Wet pulp kappa and brightness, pulp fibre properties

Primary benefits: No sample preparation required, no recalibration needed; no drifts, Rapid readings (< 45 sec)

Unique features: Data communications with direct output to plant/mill DCS, simultaneous property measurements, tcks data locally along with a day of trending, FITNIR Benchtop models can transferred to an online system

Manufacturer: Guided Wave Inc.

guided-wave.com

Product name: ClearView db

Vis-NIR Process Analyzer/Spectrometer

New this year: Stable, dual-beam, low-cost filter photometer, 400 – 2150 nm coverage,

Used for: Process analysis

Measurement Mode: Transmission

Special Features: dualbeam spectrometer/photometer. Multiple options: Enclosure Options: Z-purge Unit Class I, Division 2; ExProof Unit, Class I, division 1, ICEEx ATEX; General Purpose Unit, Modbus, 4-20mA or Ethernet data communication, Compatible with an array of fiber optic probes or flow cells, Built-in VGA touch screen, Optional temperature/pressure correction, Optional turbidity port,

Optional color display

Software: Integrated. Available as a separate product, May be used in other equipment, Compatible with other manufacturers' equipment

Suggested applications: Analysis of ethylene glycol, diethylene glycol, acid number, ethanol in gasoline, sodium hydroxide (caustic) in water, AS color, APHA color, Saybolt color, OH number in polyols, ethylene in ethylene dichloride, water in various solvents, styrene tower control, epoxy value.

Primary benefits: Dualbeam design decreases drift due to lamp aging – yields low drift long-term performance, low noise

Unique features:Choice of detector types: Si, InGaAs or InGaAs TE cooled, Touch screen interface, single or dual channel, include up to 6 filters

Manufacturer: JDSU Corporation

jdsu.com

Product name: MicroNIR Pocket Analyzer

Handheld NIR Analyzer

New this year: The MicroNIR Pocket Analyzer is a completely cordless revolutionary near infrared spectrometer. It is battery-operated and equipped for wireless communication via WiFi.

Used for: Hand-held/portable applications

Dimensions: The size of digital camera. Fits in your palm. Weight: less than 7 ounces (200 grams), the weight of an average apple.

Measurement Mode: Diffuse reflection.

Special Features: The MicroNIR fits in your pocket, is wearable on your wrist, or on tool belt, or on your arm. We have focused on designing the NIR spectrometer as the sensor while leveraging wireless communication to the internet, cloud computing, and the already existing large base of smart mobile devices for the user interface.

Software: Ability to integrate with third party software like Unscrambler or Umetrics SIMCA.

May be used in other equipment (a blender)

Suggested applications: Pharmaceutical, law enforcement, explosive detection, food/feed analysis.

Primary benefits: Field measurement, affordable, integrate with other already-existing software and hardware.

Unique features: Uses an App on a mobile phone or tablet for user interface. Doesn't contain on-board computer. Leverages existing IT systems already in use by the client.

Manufacturer: NIR Technology Systems

nextinstruments.net

Product name: Multiscan S4000

FT-NIR spectrometer

New this year: The Series 4000 is a FTNIR

Used for: Lab, Process analysis

Accessory available: Diffuse reflectance accessory with rotating dish.

Measurement Mode: Transmission, Diffuse Reflection

Features: covers the wavelength range from 800 to 2600nm., resolution selectable from 1,2, 4, 8, 16, 32 and 64 cm-1,. scan speed approximately 5 scans per second.

Software: NTAS software, which provides Scan and Display, transformation into 1st and 2nd derivative, SNV, MSC, Discriminant Analysis,: Library searching and qualitative assessment of spectra, Quantitative Analysis using PLS models, PLS calibration development routines, Spectral Matching: Calibration transfer

Available as separate product, 21CFR11 compliant, Compatible with other manufacturers' equipment.

Suggested applications: NIR analysis of stockfeeds, plant and animal meals, flour, soy bean flour and meal, corn mash, pharmaceuticals, chemicals, petrochemicals, food, agricultural products

Primary benefits: User friendly software that allows user to progress from spectral collection to calibration to analysis in one software platform. Rotating sample dish to measure a large area of sample. Rotating tablet cassette for Tablet Uniformity Testing.

Unique features: The Scan and Display routine displays spectra in cm-1 and shows the corresponding wavelength along with a most likely band assignment. The Analysis Routine uses PLS calibrations to predict new samples for up to 9 constituents, in less than 10 seconds, Spectral Matching Routine allows spectra to be imported from other instruments, aligned and a transfer algorithm developed to allow calibration transfer.

Manufacturer: Polytec

polytec.com

Product name: POLYTEC SPECTROMETER SYSTEM PSS 1721 and 2121

Diode array spectrometer, wavelength range 850-1650nm and 1100-2100nm

New this year: Wide variety of sensor heads to interface to different sample types

Used for: Lab, Process, portable/mobile operation

Dimensions: ½ 19" housing

Accessories: Sensor heads and immersible probes

Measurement Mode: Transmission or reflection, depending on probe

Specialty accessory description: Sensor heads with automated white reference.

Special Features: Standardized wavelength range for easy calibration transfer, 10-30 VFC (stabilized) power supply

Software: Proprietary, 21CFR11 compliant, cGMP compliant

Suggested applications: Process analytics

Primary benefits: Easy and reliable integration and operation

Unique features: Application specific configurations based on standardized system components.

Articles in this issue

over 13 years ago

Appendix XIV: X-Ray

over 13 years ago

Appendix IV: Fluorescence

over 13 years ago

Appendix XII: Terahertz

over 13 years ago

Appendix II: Atomic Spectroscopy

over 13 years ago

Market Profile: Biophotometers

over 13 years ago

Appendix VII: Mid-IR (FT-IR)

over 13 years ago

Appendix X: Raman

Related to this article

Monitoring Sugar Consumption and Ethanol Production During Yeast Fermentation Using a Raman Plate Reader and Multivariate Analysis
This column shows that a Raman plate reader paired with partial least squares regression can simultaneously quantify glucose, fructose, sucrose, and ethanol in yeast fermentation samples, using turbidity-matched calibration standards to correct for yeast-induced turbidity, and offers a rapid, label-free, high-throughput method for tracking sugar consumption and ethanol production in strain screening, media optimization, and process development.
Highly Substituted Benzene Rings—The Rest of the Story II: Spectra
This column, the second installment on highly substituted benzene rings, shows that tri- and tetra-substituted substitution patterns can be distinguished by whether the ring bending peak is present and by the position of the in-phase aryl C-H wagging peak, which shifts according to how many adjacent hydrogens the ring carries.